• 제목/요약/키워드: pulsed electromagnetic fields (PEMFs)

검색결과 5건 처리시간 0.016초

멀미 완화를 위한 비침습적 및 비약리적 방법 비교 및 평가 (Comparison and Evaluation of Non-invasive and Non-pharmacological Methods for Relieving Motion Sickness (MS))

  • 박승원;최준원;남상훈;최여은;이강인;정면규;신태민;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권5호
    • /
    • pp.211-224
    • /
    • 2021
  • Purpose: The purpose of this study is to present a way to alleviate motion sickness(MS) by stimulating acupoint through PEMFs, and to assess the effectiveness of PEMFs against stimulation previously used to stimulate acupoint using biosignal evaluations and surveys. Materials and Methods: Thirteen healthy men participated in the experiment. MS was induced in the participants, and MS relief stimulation was applied for 30 minutes. There were 4 types of MS relief stimulation, and Sham, Reliefband, Transcutaneous electrical nerve stimulation(TENS), and Pulsed electromagnetic fields stimulation(PEMFs) were used. The biosignals were measured during 30 minutes of applying MS relief stimulation, and the symptoms of MS were evaluated through a questionnaire survey. The measured biosignals are Electrocardiogram(ECG), Electrodermal activity(EDA), Respiration, Skin temperature(SKT), and Electrogastrogram(EGG). A one-way ANOVA test was performed for the rate of change by stimulation for MS relief over time. Results: Participants who were stimulated had a sharp decrease in MS symptoms. Biosignals were analyzed to evaluate autonomic nervous system activity, and the parasympathetic nervous system could be activated through stimulation. Conclusion: TENS and PEMFs were more effective in relieving MS symptoms than Reliefband. It is believed that PEMFs will be effective in consideration of the comfort of participants to be applied to actual vehicles, and studies to further verify the effects of PEMFs on MS should be conducted.

흰쥐에서 반회후두신경 손상후 Pulsed electromagnetic fields(PEMFs)가 기능 회복에 미치는 영향

  • 정성민;구태완;조윤희;정승용;이재연;조선희;한후재;김현태
    • 대한음성언어의학회:학술대회논문집
    • /
    • 대한음성언어의학회 1999년도 제12회 학술대회
    • /
    • pp.175-175
    • /
    • 1999
  • 배경 및 목적 : 성대마비환자에서 마비된 성대의 기능회복을 위해 여러 가지 방법으로 신경재지배를 시도하였으나 대부분이 misdirected reinnervation에 의한 후두의 synkinesis로 임상적으로 널리 이용되지 못하고 아직까지는 성대내전술등으로 음성의 질을 개선시키는 정도로만 치료하고 있는 실정이다 최근 복원에서는 반회후두신경의 절단 후 일차봉합에 의한 신경 재지배 후 후윤상피열근에 만성전기자극을 주었으나 자극을 주지 않은 대조군에 비해 후두기능회복이 더 잘된다는 결과를 확인하지 못한바 있다. 1980년대부터 pulsed electromagnetic fields (PEMFs)가 조직내에 ionic currents를 유도하여 cellular functions을 변화시킨다는 것을 보고된 이래로 PEMFs는 골절의 불유합이 있는 환자들에게 임상적으로 이용되고 있으며 최근 동물실험에서 흰쥐의 절단된 sciati nerve, common peroneal nerve, facial nerve의 신경재생을 촉진시켜 신경 재생이 조기에 되고 기능적으로 더 잘 회복되는 것으로 보고 있다. 이에 본 연구에서는 신경재생이 되더라도 기능적 회복이 힘든 것으로 알려진 반회후두신경의 재생 및 후두기능 회복에 대한 PEMFs의 영향을 알아보고자 하였다. (중략)

  • PDF

음포혈(陰包, LR9)에서 펄스형 전자기장 및 가시광 LED 복합 자극이 대퇴부 근피로 회복에 미치는 영향 분석 (The Analysis of the Muscle Fatigue Recovery Effect on LR9 by Compound Stimulation of the PEMFs and LED)

  • 이나라;김정윤;박선우;김수병;이희영;안순재;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권3호
    • /
    • pp.13-23
    • /
    • 2011
  • Objectives : The aim of this study was to develop the combined medical stimulus system consisted of the PEMFs (Pulsed electromagnetic fields) and LED which are able to stimulate local point such as acupoints and trigger points. Methods : To evaluate the therapeutic effect on the musculoskeletal disorders and the possibility of alternative method on manual acupuncture, we compared the fatigue recovery of two groups by analyzing the EMG and peak torque (non-stimulation and, stimulation group) after strenuous knee exercise. We chose the LR9 as a stimulation point. Results : The median frequency (MF) and fatigue index (F.I) of the stimulation group were recovered faster than those of the non-stimulation group. Also the peak torques of both groups were not restored until after 20 minutes. However, the peak torque of the stimulation group was regained higher than that of the non-stimulation group. Conclusions : We confirmed that the proposed combined stimulus system had useful effects as treatment instrument of musculoskeletal disorder using non-invasive method of PEMFs and LED.

세포 및 동물모델용 펄스형 전자기장 자극 파라미터 가변장치 설계 및 평가 (Design and Evaluation of Pulsed Electromagnetic Field Stimulation Parameter Variable System for Cell and Animal Models)

  • 이자우;박창순;김준영;이용흠
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권1호
    • /
    • pp.11-18
    • /
    • 2022
  • An electromagnetic generator with variable stimulation parameters is required to conduct basic research on magnetic flux density and frequency for pulsed electromagnetic fields (PEMFs). In this study, we design an electromagnetic generator that can conduct basic research by providing parameters optimized for cell and animal experimental conditions through adjustable stimulation parameters. The magnetic core was selected as a solenoid capable of uniform and stable electromagnetic stimulation. The solenoid was designed in consideration of the experimental mouse and cell culture dish insertion. A voltage and current adjustable power supply for variable magnetic flux density was designed. The system was designed to be adjustable in frequency and pulse width and to enable 3-channel output. The reliability of the system and solenoid was evaluated through magnetic flux density, frequency, and pulse width measurements. The measured magnetic flux density was expressed as an image and qualitatively observed. Based on the acquired image, the stimulation area according to the magnetic flux density decrease rate was extracted. The PEMF frequency and pulse width error rates were presented as mean ± SD, and were confirmed to be 0.0928 ± 0.0934% and 0.529 ± 0.527%, respectively. The magnetic flux density decreased as the distance from the center of the solenoid increased, and decreased sharply from 60 mm or more. The length of the magnetic stimulation area according to the degree of magnetic flux density decrease was obtained through the magnetic flux density image. A PEMF generator and stimulation parameter control system suitable for cell and animal models were designed, and system reliability was evaluated.

자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가 (Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System)

  • 김수병;박선우;안순재;이나라;이승욱;민세은;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.