• Title/Summary/Keyword: pulse-wave sensor

Search Result 107, Processing Time 0.029 seconds

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile (압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가)

  • Kim, Jung-Chae;Jee, Sun-Ha;Yoo, Sun-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Implementation of Intelligence Pulse Wave Detection System (지능형 맥진기 구현)

  • Hong, Y.S.;Yu, J.S.;Chang, S.J.;Sun, S.H.;Lee, W.B.;Nam, D.H.;Yu, M.S.;Choi, M.B.;Lee, S.S.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.245-254
    • /
    • 2013
  • In oriental medicine, it is possible to classify and treat many diseases using the pulse wave detection system. Other problems may arise. As it is a very subjective way to analyze the pulse wave. One problem of the conventional pulse wave detection system is that the arterial pulse sensor is not located correctly at the radial artery. Threrefore measurement results can differ depending on the measurement position and the measurement procedure. This is mostly due to it's sensitivity to high reproducibility. In order to solve this problem this paper proposes an algorithm to analyze the weak pulse wave symptom and strong pulse wave symptom. It uses the portable pulse wave detection system which includes a Hall Sensor. As a final result, it analyzed the weak pulse wave symptom and strong pulse wave symptom by the SPSS statistics technique. It proves that N time (notch point time) and S Amp (rise waveform size) mean values are significantly different in 95% confidence interval.

Radial Pulse Wave Detection system for the Korean Medicine (한방용(韓方用) 맥파 검출시스템)

  • Lee, H.J.;Kim, J.W.;Kim, H.O.;Park, Y.B.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.66-69
    • /
    • 1991
  • This paper describes a design of transducer for non-invasively detecting pressure radial pulse wave in aterial system and a recording system that for the studing the aterial pulse diagnosis of korean traditional medicine. The mechanism of transducer is composed of sensing mechanism, pressure sensor, conditioning amplifier. The variation of radial pulse pressure in the sensing mechanism is converted to the electric signal by piezo-resistive pressure sensor and it converted to the digital signal after preprocessing via A/D converter. The converted signals inputed to the computer as data files and then it display to the monitor for waveform watching and this datas can be used as the aterial pulse diagnosis data. This system effectively detect non-differential radial pulse wave and we conside that if analizing the recorded radial pulse wave, compared each other, it can be helpful in quantify radial pulse wave diagonosis of the Korean traditional medicine.

  • PDF

A Study on Factors Influencing P-wave Velocity of Concrete (콘크리트의 P파 속도에 영향을 주는 인자에 관한 연구)

  • 이광명;이회근;김동수;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.725-730
    • /
    • 1998
  • Recently, non-destructive tests are getting popular in evaluating concrete properties without braking specimens. Among several NDT methods, P-wave velocity measurement technique has been widely used to evaluate the stiffness and strength of concrete. The purpose of this study is to investigate factors influencing P-wave velocity measured by impact-resonant method and ultrasonic pulse velocity method, such as moisture content of concrete, existence and size of coarse aggregates, sensor and sampling rate. Test results show that rod-wave velocity measured by impact-resonant method and ultrasonic pulse velocity are significantly affected by the moisture content of concrete, i.e., the lower moisture content, the lower velocity. Moisture content influences rod-wave velocity stronger than ultrasonic pulse velocity. Rod-wave velocity is faster in concrete than in mortar and is also faster in concrete containing small size aggregates. Sensor and sampling rate have little influence on velocity.

  • PDF

Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor (어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성)

  • Choi, Yong-Seok;Kim, Kyung-Yo;Hwang, Seung-Yeon;Kim, Jong-Yeol;Lee, Si-Woo;Kim, Hyun-Hee;Joo, Jong-Cheon
    • Korean Journal of Acupuncture
    • /
    • v.24 no.3
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor (영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구)

  • Yoo, Gi-Doo;Hwang, Sung-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.1
    • /
    • pp.27-31
    • /
    • 2012
  • Two radially arterial pulses of both hands using the prototype of a clamping clip pulsimeter equipped with permanent magnet and Hall device are compared and analyzed. The phase difference of two pulse wave signals is dominantly presented from the simultaneous measuring clinical pulse wave signals for twenty two male participants at their 20's. It is possible to analyze that the fast and slow pulse wave for right hand and left hand depend on the muscle property of arms rather than the total length of blood vessel due to cardiovascular circulatory system.

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

Volume Pulse Wave Detection System for Oriental Medicine (한방용 용적맥파 시스템)

  • Kim, H.T.;Han, S.C.;Choi, T.J.;Kim, J.K.;Huh, W.;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, we devised volume pulse detection system which can quantitatively represent a artery elasticity for oriental clinic. Volume pulse wave detecter system consist of transducer which has IRLED-photodiode detecter, temperature sensor and filter and preprocessing circuits, data conversion and serial communication parts, and computer system. The high-pass filter are detect volume pulse wave and lowpass filter detect tissue thickness. The detected volume pulse wave are normalized by tissue thickness value with a division process. As the result of experiment, we can detect normalized volume pulse wave with effectively.

  • PDF