• 제목/요약/키워드: pulse-tube

검색결과 254건 처리시간 0.024초

극저온 맥동 압력 조건에서의 재생기에 관한 실험적 연구 (Experimental Study on Regenerator Under Cryogenic Temperature and Pulsating Pressure Conditions)

  • 남관우;정상권;정은수
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1095-1101
    • /
    • 2002
  • An experimental apparatus was prepared to investigate thermal and hydrodynamic characteristics of regenerator at cryogenic temperature under pulsating pressure condition. The regenerator was pressurized and depressurized by a compressor with various operating frequencies. Cold end of the regenerator was maintained around 100 K by means of a liquid nitrogen heat exchanger. Instantaneous gas temperature and mass flow rate were measured at both ends of the regenerator during the whole pressure cycle. Pulsating pressure drop across the regenerator was also measured to see if it could be predicted by a friction factor at steady flow condition. The operating frequency of pressure cycle was varied between 3 and 60 Hz, which are typical operating frequencies of Gifford-McMahon, pulse tube, and Stilting cryocoolers. First, the measured friction factor for typical wire screen mesh regenerator was nearly same as steady flow friction factor for maximum oscillating Reynolds number up to 100 at less than 9 Hz. For 60 Hz operations, however, the discrepancy between oscillating flow friction factor and steady flow one was noticeable if Reynolds number was higher than 50. Second, the ineffectiveness of regenerator was directly calculated from experimental data when the cold-end was maintained around 100 K and the warm-end around 293 K, which simulates an actual operating condition of cryogenic regenerator. Influence of the operating frequency on ineffectiveness was discussed at low frequency range.

$C_2H_2F_4$ 이성질체의 탈플루오르화 수소반응에 있어서의 비교연구 (Comparative Study of the Dehydrofluorination of the Structural Isomers of $C_2H_2F_4$)

  • ;;;정경훈
    • 대한화학회지
    • /
    • 제23권3호
    • /
    • pp.132-135
    • /
    • 1979
  • 1,1,2,2-$C_2H_2F_4$와 1,1,1,2-$C_2H_2F_4$의 아르곤가스와의 묽은 혼합물의 열분해반응을 충격관을 사용 1146와 $1232^{\circ}K$하 전체반사충격압의 3000 torr 근처에서 관찰하였다. 이들 조건하에서 반응은 주로 플루오르화수소의 분자제거반응을 보였다. ${\alpha}$-탄소의 수소가 전부 플루오르로 치환된 이성질체는 다른 이성질체에 비하여 상당히 높은 활성화에너지를 나타내었으며 이는 이성질체간에 전하밀도의 차이에 기인한 것으로 추측된다. 반응속도 상수의 비는 다음식 $log(k_1/k_2) = -0.069 {\pm} 0.021 + (1388{\pm}113)/ 2.303RT$ 로 주어졌으며 이는 독립된 관측을 통해서 얻어진 값들과 좋은 일치를 보여 주었다.

  • PDF

고온 접촉식 탐상용 초음파 탐촉자 개발 및 평가 (Development and Characterization of Ultrasonic transducers for High Temperature Contact Measurement)

  • 김기복;김병극;이승석;윤남원;윤동진;안윤국
    • 비파괴검사학회지
    • /
    • 제23권1호
    • /
    • pp.14-20
    • /
    • 2003
  • 고온$(500^{\circ}C)$ 환경에서 접촉식 탐상이 가능한 초음파 탐촉자를 개발하고 평가하였다. 고온용 탐촉자는 Curie 온도가 $600^{\circ}C$ 이상인 bismuth titanate 계열의 압전세라믹 소자, 텅스텐 분말과 inorganic binder를 혼합한 후면재, 알루미나 튜브, 전면재, 하우징 등으로 구성되었다. 기본 공진주파수가 각각 1.04 및 2.08 MHz의 2 종류 탐촉자를 제작하였으며 각종 고온용 커플런트의 온도특성을 시험하였다. 개발된 고온용 탐촉자를 이용하여 강재 시편을 대상으로 시편에서의 초음파 반사신호를 측정한 결과 시편의 온도가 증가함에 따라 반사신호의 크기는 감소하였다. 고온에서 반복측정 실험결과 $500^{\circ}C$에서 연속적인 접촉식 초음파 탐상이 가능한 것으로 나타났다.

The detection of cavitation in hydraulic machines by use of ultrasonic signal analysis

  • Gruber, P.;Farhat, M.;Odermatt, P.;Etterlin, M.;Lerch, T.;Frei, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.264-273
    • /
    • 2015
  • This presentation describes an experimental approach for the detection of cavitation in hydraulic machines by use of ultrasonic signal analysis. Instead of using the high frequency pulses (typically 1MHz) only for transit time measurement different other signal characteristics are extracted from the individual signals and its correlation function with reference signals in order to gain knowledge of the water conditions. As the pulse repetition rate is high (typically 100Hz), statistical parameters can be extracted of the signals. The idea is to find patterns in the parameters by a classifier that can distinguish between the different water states. This classification scheme has been applied to different cavitation sections: a sphere in a water flow in circular tube at the HSLU in Lucerne, a NACA profile in a cavitation tunnel and two Francis model test turbines all at LMH in Lausanne. From the signal raw data several statistical parameters in the time and frequency domain as well as from the correlation function with reference signals have been determined. As classifiers two methods were used: neural feed forward networks and decision trees. For both classification methods realizations with lowest complexity as possible are of special interest. It is shown that two to three signal characteristics, two from the signal itself and one from the correlation function are in many cases sufficient for the detection capability. The final goal is to combine these results with operating point, vibration, acoustic emission and dynamic pressure information such that a distinction between dangerous and not dangerous cavitation is possible.

DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용 (Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge)

  • 최유리;김동주;김교선
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발 (Development of pulse diagnosis possible simulator using the stepper motor pumps)

  • 류근택;우성희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.915-918
    • /
    • 2016
  • 의료산업의 급속한 변화와 의료 및 간호 인력의 증가로 인하여 가상 시험 장치에 대한 개발이 요구되고 있으며 심장 모델링할 수 있는 시뮬레이터와 혈관, 혈류에 대한 실습장비에 대한 개발의 중요성이 증가하고 있다. 따라서 본 연구에서는 스텝 모터를 이용하여 심장 펌프를 제작하여 동맥과 정맥 혈압, 혈류 시뮬레이션을 위한 장비를 개발하고 그 기능을 평가하고자 한다. 제안 시스템은 심장 시뮬레이션을 위한 펌프와 동맥, 정맥 혈관의 저항을 모사하기 위한 밸브장치 그리고 정맥계의 특성을 나타내는 저감장치로 구성한다. 심장 시뮬레이터는 롱거펌프(BOXER)를 사용하였으며 동맥과 정맥혈관은 실리콘 튜브를 사용하고 저감장치를 설계 및 제작하였다. 그리고 동맥혈압 측정을 위하여 압력센서를 사용하였다. 또한 제안 시스템의 평가를 위하여 심장 박동수는 분당 60회로 혈압의 범위는 50 ~ 100mmHg로 선정하여 측정 혈압과 사람의 혈압을 비교 평가하였다.

  • PDF

스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성 (Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement)

  • 김태형;고기영;송호영;박인국;신지훈;임진오;김진형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.205-212
    • /
    • 2007
  • 대동맥류 질환에 사용되는 스텐트그라프트의 체외실험을 위한 대동맥류 혈류 팬텀의 유효성과 실현가능성에 대해 평가하고자 한다. 팬텀은 인체의 혈류 조건과 유사한 상황을 재현할 수 있도록 심장부분과 대동맥류 부분으로 구성되었다. 심장부분은 고압력 수중펌프와 솔레노이드 밸브를 사용하여 심장의 대동맥 혈류를 재현하였고, 대동맥류 부분은 지점토를 사용하여 동맥류 모양을 재현하고 그 틀을 투명 실리콘으로 틀을 떠내는 방법으로 제작하였다. 두부분은 실리콘 관으로 연결하였다. 제작된 팬텀에서 밸브의 개폐 시간에 따른 압력(수축기/이완기) 변화를 측정하였으며, 스텐트그라프삽입술 전, 후의 압력변화를 측정하였으며, 통계적 유의성을 알아보았다. 밸브의 개폐 시간에 따른 압력 변화는 통계적으로 유의한 결과를 보였다(P<0.05). 0.5회/초의 개폐조건에서는 팬텀의 대동맥 근위부, 대동맥류, 원위부의 압력은 각각 $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$이었으며, 1.0회/초의 개폐 조건에서는 $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$이었고, 1.5회/초의 개폐 조건에서는 $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$이었다. 스텐트그라프삽입술 전, 후의 팬텀의 압력변화는 대동맥부분에서 측정하였으며, 각각 $143.60{\pm}1.67/90.20{\pm}1.64$, $47.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$이었다. 결론적으로, 대동맥류 팬텀은 압력의 범위를 다양하게 적용할 수 있고, 팬텀 내에서 시술의 재현이 가능하여 동물실험 전 스텐트그라프트의 유용성을 평가하기 위한 체외실험 기구로 유용할 것으로 기대된다.

  • PDF

Catecholamines에 관(關)하여 -제4편(第四編) : 심실전동발생(心室顫動發生)에 있어서의 catecholamines의 의의(意義)- (Role of Catecholamines in Ventricular Fibrillation)

  • 이우주
    • 대한약리학회지
    • /
    • 제19권1호
    • /
    • pp.15-35
    • /
    • 1983
  • Although it has been well known that ventricular fibrillation is the most important complication during hypothermia, much investigation has failed to show the exact nature of the etiology of ventricular fibrillation. Recently, there has been considerable research on the relationship between sympathetic activity and ventricular fibrillation under hypothermia. Cardiac muscle normally contains a certain amount of norepinephrine and the dramatic effect of this catecholamines on the cardiac muscle is well documented. It is, therefore, conceivable that cardiac catecholamines might exert an influence on the susceptibility of heart muscle to tachycardia, ventricular fibrillation and arrhythmia, under hypothermia. Hypothermia itself is stress enough to increase tonus of sympatheticoadrenal system. The normal heart is supplied by an autonomic innervation and is subjected to action of circulating catecholamines which may be released from the heart. If the reaction of the heart associated with a variable amount of cardiac catecholamines is. permitted to occur in the induction of hypothermia, the action of this agent on the heart has not to be differentiated from the direct effects of cooling. The studies presented in this paper were designed to provide further information about the cardio-physiological effects of reduced body temperature, with special reference to the role of catecholamines in ventricular fibrillation. Healthy cats, weighing about 3 kg, were anesthetized with pentobarbital(30 mg/kg) intraperitoneally. The trachea was intubated and the endotracheal tube was connected to a C.F. Palmer type A.C. respirator. Hypothermia was induced by immersing the cat into a ice water tub and the rate of body temperature lowering was $1^{\circ}C$ per 5 to 8 min. Esophageal temperature and ECG (Lead II) were simultaneously monitored. In some cases the blood pH and serum sodium and potassium were estimated before the experiment. After the experiment the animals were killed and the hearts were excised. The catecholamines content of the cardiac muscle was measured by the method of Shore and Olin (1958). The results obtained are summarized as follows. 1) In control animal the heart rate was slowed as the temperature fell and the average pulse rates of eight animals were read 94/min at $31^{\circ}C$, 70/min at $27^{\circ}C$ and 43/min at $23^{\circ}C$ if esophageal temperature. Ventricular fibrillation was occurred with no exception at a mean temperature of $20.3^{\circ}C(21-l9^{\circ}C)$. The electrocardiogram revealed abnormal P waves in each progressive cooling of the heart. there was, ultimately, a marked delay in the P-R interval, QRS complex and Q-T interval. Inversion of the T waves was characteristic of all animals. The catecholamines content of the heart muscle excised immediately after the occurrence of ventricular fibrillation was about thirty percent lower than that of the pre-hypothermic heart, that is, $1.0\;{\mu}g/g$ wet weight compared to the prehypothermic value of $1.41\;{\mu}g/g$ wet weight. The changes of blood pH, serum sodium and potassium concentration were not remarkable. 2) By the adrenergic receptor blocking agent, DCI(2-3 mg/kg), given intramuscularly thirty minutes before hypothermia, ventricular fibrillation did not occur in one of five animals when their body temperature was reduced even to $16^{\circ}C$. These animals succumbed at that low temperature, and the changes of heart rate and loss of myocardial catecholamines after hypothermia were similar to those of normal animals. The actual effect of DCI preventing the ventricular fibrillation is not predictable. 3) Administration of reserpine(1 mg/kg, i.m.) 24 hours Prior to hypothermia disclosed reduced incidence of ventricular fibrillation, that is, six of the nine animals went into fibrillation at an average temperature of $19.6^{\circ}C$. By reserpine myocardial catecholamines content dropped to $0.045\;{\mu}g/g$ wet weight. 4) Bretylium pretreatment(20 mg/kg, i.m.), which blocks the release of catecholamines, Prevented the ventricular fibrillation under hypothermia in four of the eight cats. The pulse rate, however, was approximately the same as control and in some cases was rather slower. 5) Six cats treated with norepinephrine(2 mg/kg, i.m.) or DOPA(50 mg/kg) and tranylcypromine(10 mg/kg), which tab teen proved to cause significant increase in the catecholamines content of the heart muscle, showed ventricular fibrillation in all animals under hypothermia at average temperature of $21.6^{\circ}C$ and the pulse rate increased remarkably as compared with that of normal. Catecholamines content of cardiac muscle of these animals markedly decreased after hypothermia but higher than control animals. 6) The functional refractory periods of isolated rabbit atria, determined by the paired stimulus technique, was markedly shortened by administration of epinephrine, norepinephrine and isoproterenol. 7) Adrenergic beta-blocking agents, such as pronethalol, propranolol and sotalol(MJ-1999), inhibited completely the shortening of refractory period induced by norepinephrine. 8) Pretreatment with either phenoxftenbamine or phentolamine, an adrenergic alphatlocking agent, did not modify the decrease in refractory period induced by norepinephrine. From the above experiment it is possible to conclude that catecholamines play an important role in producing ventricular fibrillation under hypothermia. The shortening of the refractorf period of cardiac muscle induced by catecholamines mar be considered as a partial factor in producing ventriculr fibrillaton and to be mediated by beta-adrenergic receptor.

  • PDF

S대역 군사 레이더용 2kW급 GaN HEMT 증폭기 개발 (Development of 2-kW Class C Amplifier Using GaN High Electron Mobility Transistors for S-band Military Radars)

  • 김시옥;최길웅;유영근;임병옥;김동길;김흥근
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.421-432
    • /
    • 2020
  • 본 논문에서는 S-밴드 군용 레이더에 사용되고 기존의 TWTA를 대체하기 위해 GaN HEMT 기반 증폭모듈을 이용하여 개발한 2kW급 반도체증폭기(SSPA)를 제안하였다. 제안한 SSPA는 8개의 증폭모듈로 이루어진 고출력증폭모듈, 구동증폭모듈, 제어모듈 및 전원공급 장치로 이루어져 있다. 제안한 SSPA는 1) 증폭모듈과 구성부품은 공간적 제약으로 작은 패키지에 통합설계 되었으며, 2) PCB 내장형 하모닉필터를 이용하여 고주파를 제거하였으며, 그리고 3) 입력신호의 듀티 변화에 대응하여 일정한 출력이 유지되도록 하는 자동이득조절기를 설계하였다. 제안된 SSPA는 최대 48 dB의 이득과 3.1~3.5 GHz의 주파수 대역에서 63-63.6 dBm의 출력 전력을 보였다. 자동이득조절 기능은 15-20 dBm의 입력전력 변동에도 대해서, 출력전력이 63dBm 전후로 일정하게 유지하는 것을 확인하였다. 마지막으로 MIL-STD-810의 시험기준을 만족하는 높은 (55 ℃) / 낮은 (-40 ℃) 온도시험 프로파일을 이용한 온도시험을 통해 개발된 시스템의 신뢰성을 검증하였다. 개발된 SSPA는 경량, 고출력, 고이득, 안전기능, 낮은 수리비, 짧은 수리시간 등 측면에서 기존의 TWTA 증폭기보다 우수한 것을 확인하였다.

피부과용$CO_2$ 레이저의 공극(1.0mm및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성 연구 (Special quality research about action output waveform change by gap (1.0mm and 1.6mm)difference of skin excessive expense $CO_2$ Laser)

  • 김휘영
    • 한국컴퓨터산업학회논문지
    • /
    • 제8권2호
    • /
    • pp.107-112
    • /
    • 2007
  • 피부과용 레이저 파장은 아주 얇은층의 조직두께에서 물의 흡수가 거의 90%이상 일어나는데 병소의 표피나 조직은 거의 물로 구성되어 흡수로 인해 증발효과를 가질 수가 있다. 표피를 절개, 층별로 증발 시킬 수 있으며 조직의 정확한 절개가 가능하다. 혈관이나 림프시스템에도 봉합수술이 가능하고 수술부위가 건조하고 눈으로 볼수 있고 무출혈 수술이 가능하다. 특히, 펄스에 대한 튜브양단 출력의 안정이 매우 중요함으로, 본 연구에서는 고주파 방식의 전력변환 장치를 사용하여 부피를 줄이고 의료용 레이저의 전류파형을 쉽게 제어할 수 있어 다양한 치료 효과를 낼 수 있다. ZVS(Zero Voltage Switching)나 ZVZCS(Zero Voltage and Zero Current Switching)를 도입하면 스위칭 손실을 줄일 수 있어 더욱 유리하다. 제안된 의료용 레이저의 전력부에는 1차측 도움에 의한 ZVZCS기법을 도입하여 넓은 부하 범위에서 안정된 soft-switching을 할 수가 있고 제어부는 microcontroller를 구성하여 출력전류 파형을 사용자가 임의의 형태를 갖도록 하였다. 설계 및 제작하여 실험한 결과, 기존장비에 비해 20%의 향상된 결과를 가져왔고, 추후 시스템적으로 보완을 하면 우수한 결과가 될 것으로 사려된다.

  • PDF