• Title/Summary/Keyword: pulse-tube

Search Result 254, Processing Time 0.031 seconds

Pulseless Disease: Report of Two Cases (무맥증 수술치험 2례)

  • 박응범
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.127-132
    • /
    • 1970
  • A patient was 29 year old house wife who was admitted to the Yonsei University Medical Center on 6 th of Nov., in 1970, with chief complaints of complete loss of bilateral visual acuity, generalized weakness, frequent palpitations, claudication of masseter muscles and intermittent fainting. These symptoms were developed 5 years prior to admission. Physical finding on admission revealed complete loss of bilateral visual acuity, absence of both radial and carotid pulse, but there was good femoral and popliteal pulse. She couldn't open her mouth as she desired and had weakness of mastication. Radiological findings of plane chest PA were not significant. Aortogram(Cineangiogram) showed non-visualization of both carotid and subclavian arteries. It showed only innominate and interal mammary artery preoperatively. The operative findings were as follows: There were complete obliterative changes in both common carotid and subclavian arteries, and periarteritis in the innominate artery. Tube Dacron Prosthesis Bypass with V-arm between innominate artery and both common carotid arteries was performed after thromboendarterectomy. Histopathological finding of the thromboend arterectomy specimen was compatible with pulseless disease, which showed marked fibrous thickening of intima and a diffuse inflammatory cell infiltration of the whole layers. Her postopererative course was uneventful. Follow up aortogram(Cineangiogram) was taken on 11th postoperative day, which revealed both common carotid arteries patent. Her preoperative Subjective symtoms disappeared remarkably, such as her visual acuity improved much, fainting and vertigo disappeared completely and she can go to bath room without difficulty and help. Another patient was 34 year old house wife who was admitted on August, 1964 with chief complaints of frequent fainting and progresive visual loss. She was operated only thromboendarterectomy of both common carotid arteries. Postoperative course was smooth and subjective symptoms were disappeared.

  • PDF

Design and Analysis of High Frequency High Power Density. High Voltage Pulse Transformer for Travel Wave Tube(TWT) High Voltage Power Supply (진행파관 고전압전원공급기의 고주파수, 고밀도, 고전압 펄스변압기의 설계 및 해석)

  • Kim, S.C.;Jung, S.H.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1043-1045
    • /
    • 2002
  • 고전압 전원공급기를 고 밀도로 제작하기 위하여 고 주파수 동작을 시켜야 한다. 이에 따라 전원 공급기에서 최대의 부피를 차지하는 부품인 변압기는 원하는 주파수에서 최소의 부피로 충분한 전력을 수용하면서 완벽한 펄스재현을 하여야 한다. 고전압 전원공급기는 풀-브릿지 DC/DC 컨버트로 구성되어 있으며 스윗칭 주파수는 100 kHz 이다. 변압기는 일차권선이 1개이며 이차 권선은 4개로 구성된다 일차전압은 250 Vdc, 이차 권선 각각의 출력은 520 Vrms이다. 변압의 이차 권선은 배 전압 회로를 이용하여 승압 후 각각을 직렬로 연결하여 -4,100 VDC와 -2,050 VDC를 만들어 TWT(Travel Wave Tube)의 케소드 및 콜렉트에 공급한다. 이 변압기는 100 kHz 펄스로 동작하고 최대부피가 400$cm^3$이하가 되어야 한다. 본 논문에서는 이러한 변압기의 설계 방법 및 최소 온도상승을 위한 적절한 동작 자속밀도의 선택에 대하여 기술하고 변압기의 누설 인덕턴스, 분포 케페시턴스, 공진 주파수에 대하여 설계치 및 실험치를 비교 평가하였다.

  • PDF

Performance test of 100 W linear compressor

  • Ko, J.;Koh, D.Y.;Park, S.J.;Kim, H.B.;Hong, Y.J.;Yeom, H.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.35-39
    • /
    • 2013
  • In this paper, we present test results of developed 100 W class linear compressor for Stirling-type pulse tube refrigerator. The fabricated linear compressor has dual-opposed configuration, free piston and moving magnet type linear motor. Power transfer, efficiency and required pressure waveform are predicted with designed and measured specifications. In experiments, room temperature test with flow impedance is conducted to evaluate performance of developed linear compressor. Flow impedance is loaded to compressor with metering valve for flow resistance, inertance tube for flow inertance and buffer volumes for flow compliance. Several operating parameters such as input voltage, current, piston displacement and pressure wave are measured for various operating frequency and fixed input current level. Behaviors of dynamics and performance of linear compressor as varying flow impedance are discussed with measured experimental results. The developed linear compressor shows 124 W of input power, 86 % of motor efficiency and 60 % of compressor efficiency at its resonant operating condition.

Development of High Voltage Pulse Power Supply for Gyroklystron Tube (Gyroklystron Tube 구동을 위한 고전압 펄스 전원장치의 설계 및 개발)

  • Park, Jae-An;Youn, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.71-73
    • /
    • 2000
  • 최근 고 에너지 저장 및 발생장치의 개발은 군사용에서 산업용으로 응용되면서 각종 첨단 설비가 개발되고 있다. 본 논문에서는 전자빔 발생기로 쓰이는 Gyroklystron용 대전력, 고전압, 전류 펄스 전원장치로 입력부, 특고압 발생부, 고압 정류부 및 IGBT 펄스 스위치 구성하고 그 설계 및 개발 자료에 대하여 기술하였다. 대전력 고전압 전류펄스 전원장치를 위한 각 구성 부분의 제어 및 설계 특징은 다음과 같다. 입력부인 IGBT Inverter는 펄스 전원장치의 제어를 위하여 출력 고전압을 Feedbark System에 의해 펄스 설정 전압을 유지하도록 제어하며, 또한 펄스 출력중에 직류 고전압부의 전압강하, 즉 펄스 진압의 Drop이 커지는 것을 방지하기 위하여 Fast Dynamics를 갖도록 Feedback System을 구성하였다. 단상 특고압 승압용 변압기 3대를 직렬접속한 특고압 발생부는 PWM 제어된 전압을 입력받아 특고압으로 승압시키며 고압 펄스성 전압과 매우 높은 dV/dt 전압이 인가되므로 Stray Capacitance가 최소가 되어야 하며 절연파괴로부터 보호될 수 있어야 한다. 고압 정류부는 Inverter와 특고압 변압기에 의하여 전원이 공급되므로 교류전압의 교번 순간에 매우 높은 전압변동률을 가지는 Fast Recovery High Voltage Rectifier로 설계 제작되어졌다. 펄스 스위치인 IGBT 스위치는 Gate Driver에 의해 구동되어 지며 주어진 펄스 사양을 만족시키게 된다. 특히 소자의 전압특성을 고려하여 120KV의 전압 값을 갖도록 설계, 제작하였다.

  • PDF

In vitro application of Angiographic PIV technique to blood flows (Angiographic PIV 기법을 이용한 혈액유동의 in-vitro 연구)

  • Kim, Guk-Bae;Lim, Nam-Yun;Jung, Sung-Yong;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.105-108
    • /
    • 2007
  • To diagnose the vascular diseases from the viewpoint of hemodynamics, we need detailed quantitative hemodynamic information of related blood flows with a high spatial resolution of tens micrometer and a high temporal resolution in the order of millisecond. For investigating in-vivo hemodynamic phenomena of vascular circulatory diseases, a new diagnosing technique combining a medical radiography and PIV method was newly developed. This technique called 'Angiographic PIV system' consists of a medical X-ray tube, an X-ray CCD camera, a shutter module for generating double pulse-type X-ray, and a synchronizer. Through several preliminary tests, the feasibility of the Angiographic PIV technique was verified. For in-vivo applications to real blood flows, we developed tracer microcapsules, which were optimized to this system, made of a contrast material of iodine and a matrix material of PVA (polyvinylpyrrolidone). In near future, the Angiographic PIV technique will be used for understanding hemodynamic phenomena of vascular diseases and for their early detection.

  • PDF

Monitoring degradation in concrete filled steel tubular sections using guided waves

  • Beena, Kumari;Shruti, Sharma;Sandeep, Sharma;Naveen, Kwatra
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.371-382
    • /
    • 2017
  • Concrete filled steel tubes are extensively applied in engineering structures due to their resistance to high tensile and compressive load and convenience in construction. But one major flaw, their vulnerability to environmental attack, can severely reduce the strength and life of these structures. Degradation due to corrosion of steel confining the concrete is one of the major durability problems faced by civil engineers to maintain these structures. The problem accelerates as inner surface of steel tube is in contact with concrete which serves as electrolyte. If it remains unnoticed, it further accelerates and can be catastrophic. This paper discusses a non-destructive degradation monitoring technique for early detection corrosion in steel tubes in CFST members. Due to corrosion, damage in the form of debonding and pitting occurs in steel sections. Guided ultrasonic waves have been used as a feasible and attractive solution for the detection and monitoring of corrosion damages in CFST sections. Guided waves have been utilized to monitor the effect of notch and debond defects in concrete filled steel tubes simulating pitting and delamination of steel tubes from surrounding concrete caused by corrosion. Pulse transmission has been used to monitor the healthy and simulated damaged specimens. A methodology is developed and successfully applied for the monitoring of concrete filled steel tubular sections undergoing accelerated chloride corrosion. The ultrasonic signals efficiently narrate the state of steel tube undergoing corrosion.

A study on the optimization design of pulse air jet system to improve bag-filter performance (여과집진기의 탈진 성능 향상을 위한 충격 기류 분사 시스템 최적화 설계에 관한 연구)

  • Hong, Sung-Gil;Jung, Yu-Jin;Park, Ki-Woo;Jeong, Moon-Heon;Lim, Ki-Hyuk;Suh, Hye-Min;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3792-3799
    • /
    • 2012
  • The dedusting characteristics of pulse air jet type dedusting system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the dedusting performance in modified shape of dedusting unit was compared in this study. The review on the dedusting air volume, air stream distribution and inflow velocity distribution on each shape of dedusting part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1) which is widely applied in the field in its amplification effect on the air volume and extension of stream width. The specification of venturi was decided to apply the selected Case-5 for the option of the commercial back filter. It is considered that the dedusting air volume will be maintained in maximum in the case of 50 mm and 90 mm for the diameter of internal and external intaking pipe respectively.

Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment (자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.256-265
    • /
    • 2009
  • Laser output becomes output adjustment from 20 w to 100 w consecutively and time of exposure is available adjustment through water plant in 0.01 seconds. Pulse action can intercept laser beam periodically and supermarket pulse 0.1 $\sim$ between 1ms discharge consist and momentary laser output is increased to 5 $\sim$ 10. Specially, that must remove malignancy cell in womb nine escarps in the case of uterine cancer first of all stability of tube output about pulse by weight very, stable soft switching action area is defined without high frequency transformer leakage inductance ($L_1$) increase and additional series inductor insertion to converter the first main circuit securing zero voltage and marks of switching action in this research specially, because circulation current path of inductor ($L_f$) current is intercepted, converter the first main circuit switching component and spiritual enlightenment damage of high frequency transformer take decreasing greatly and high frequency the second stoppage department ($D_5,\;D_6$) becomes soft switching, and also, switching damage absorption quantity characteristic that can come to life again as subordinate have, and to become tube stabilization design and result that manufacture and experiment, brought result that improve of 10% than existing equipment, and if supplement as systematic late, it becomes thought to get into superior result.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

Development of Pulse Analysis System Based on Convenience and Compactness (사용 편의성과 소형화 기반의 맥파 측정장치 개발)

  • Cho, JungHee;Bae, JangHan;Kim, YoungMin;Jun, MinHo;Yang, TaeHeon;Jeon, YoungJu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.168-174
    • /
    • 2017
  • To improve and downsize the KIOM-Pulse Analysis System(KIOM-PAS), which has been traditionally used in clinical trials, a miniaturized PAS(M-PAS) with a pneumatic pump has been developed. M-PAS is composed of a measurement module and an arm-mounting module, on which an arm can be placed. The measurement module is equipped with a pressing component and sensor, which is a wearable wristband. The arm-mounting module includes a pneumatic motor, data acquisition board and valves. In addition, the measurement module is divided into a fixing module of band type for attachment to a pulsation site and a sensing module, which includes a sensor and a tube. The fixing module and sensing module are constructed independently, and the detachable fastening method improves the posture convenience of the subject during measurement. M-PAS has been reduced to 1/6 the size of KIOM-PAS, and the measurement time is shortened by 22%. Using a simulator, the difference between the waveforms measured by the two devices exhibited a high degree of similarity of within 3.65%. M-PAS represents improvements in size and convenience compared with KIOM-PAS, and it is expected to be widely used in clinics in the future because it improves the attachment method of the fixing module.