• 제목/요약/키워드: pulse-forming circuit

검색결과 21건 처리시간 0.033초

PFN을 이용한 펄스발생기의 연구 (A Study on the Pulse Generator using PFN)

  • 이복희;정관모;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1773-1775
    • /
    • 1998
  • This paper deals with the pulse generator using PFN(Pulse Forming Network), and its operation characteristics and application. Two kinds of pulse generator were composed of the best appropriate condition circuit. The output current of the one pulse generator has the rise time of 28 ns and the pulse duration of $7{\mu}s$. The other pulse generator has high current of about 2kA. By use of the former generator with rapid rise time, the impulse impedance characteristic of ground electrodes was investigated with measuring the ground potential rise when the pulse current was injected into the ground electrode.

  • PDF

다수 스위칭 제어를 통한 Multi-Discharge방식의 고체레이저 출력파형 연구 (A study of the output waveform of solid-state laser of multi-discharge method by various switching control)

  • 곽수영;김상길;홍정환;노기경;강욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1852-1854
    • /
    • 2003
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing. In order to make various pulse shapes with variable pulse length and high duty cycle, We have fabricated the power supply consisting 6 SCRs and the Pulse Forming Network(PFN) with the precise delay time control. So our control system has three switching circuits, 3 mesh PFN, and simmer circuit. In addition, we have designed and fabricated the PIC one-chip microprocessor(16F877) to control the delay time of sequential switching.

  • PDF

질소산화물 제거를 위한 펄스코로나 방전공정의 에너지 소모 저감에 관한 연구 (Study on the Reduction of Energy Consumption in the Pulsed Corona Discharge Process for NOx Removal)

  • 정재우;손병학;조무현;목영선;남궁원
    • 한국대기환경학회지
    • /
    • 제15권4호
    • /
    • pp.475-483
    • /
    • 1999
  • A lab-scale test was carried out to study the reduction of electrical energy consumption in the pulsed corona discharge process for nitrogen oxides removal. The experiment was mainly focused on 1) the activation of pollution removal reactions by chemical additives and 2) the optimization of electrical circuit for the efficient energy transfer from the power supply to the corona reactor. Hydrocarbon chemical additives used in the experiment are thought to be responsible for the enhancement of the NO conversion through the chain reactions of free radicals such as, R, RCO, and RO. Electrical energy consumption per converted NO molecule has a minimum value of 17 eV when pentanol is injected. When ethylene and propylene are injected, 30 eV and 22 eV of electrical energy consumption is required for the conversion of NO molecule respectively. The ratio of the pulse forming capacitance$(C_e)$ to the reactor capacitance$(C_R)$ plays an important role in the energy transfer efficiency to the reactor. Maximum energy transfer efficiency of approximately 72% could be obtained by using the pulse forming capacitance which is 3.4 times larger than the reactor capacitance, and also the maximum NO conversion efficiency was observed with the same condition.

  • PDF

Pico second 기립시간의 충격 전자기파 발생기의 개발 (Development of an Impulse Electromagnetic Wave Generator having Rise time of Pico Second)

  • 김영배;이홍식;정순신
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.597-600
    • /
    • 2006
  • When the energy of the nanoseconds high voltage pulse with hundreds picoseconds of the pulse rise time is emitted into the free space via an antenna, an ultra wide band electromagnetic wave is generated. This electromagnetic wave is expected to be used in transmitting vast amount of informations to far distance, high performance radars, post-packaging pasteurization of food, the detection of underground buried objects, searching of underground water veins or caves, the treatment of waste water or polluted gases and so forth. Additionally, this technology can be used in EMI(electromagnetic interference) evaluation of measuring instruments or printed circuit boards.

펄스전력용 광점호 싸이리스터의 특성 연구 (A Study on Characteristics of Light Triggered Thyristor for Pulsed Power Application)

  • 이병하;김진성;김영배;차한주
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.762-767
    • /
    • 2010
  • This paper describes characteristic of a light triggered thyristor investigated by experiment to adopt it into a main switch of a pulsed power unit. Triggering principle of the light triggered thyristor are referred with its structure and equivalent circuit. Operational principle and simulation result of a capacitive pulsed power circuit are explained. A variety of triggering conditions of triggering circuit and characteristics on turn-on, turn-off, voltage dividing in series operation, overvoltage protection function of the light triggered thyristor are investigated by experiments. Experimental result of 40 kJ pulsed power unit using the light triggered thyristor is presented.

고출력 레이저-증폭기 계열의 Isolator 설계-(II) (Design of an Isolator of High Power Laser-Amplifier Series-(II))

  • 나승환
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1989년도 제4회 파동 및 레이저 학술발표회 4th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.7-11
    • /
    • 1989
  • A Faraday rotator is designed with the HOYA FR-5 rotator glass. We find that traveling light rotates 45$^{\circ}$in the glass when magnetic field intensity is about 3.0$\times$105AT/m. The current of 2.7KA flowing in the coil of the 0cm diameter, 29cm long and 41 windings generates this magnetic field. A pulse forming network is designed for this current of 84 sec duration. The network is analyzed numerically to find the relevant circuit parameters for the flattest current waveform.

  • PDF

200-MW 모듈레이터의 동작 특성 및 고조파 해석 (Operation Characteristic and Harmonic Analysis of 200-MW Modulator)

  • 박성수;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Modulator의 출력안정도 향상을 위한 DeQing Controller 개발 (The development of a deQing controller to improve the output of a modulator)

  • 김상희;박성수;황정연;한영진;남상훈;오종석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.123-125
    • /
    • 2007
  • 포항가속기연구소가 추진 중인 제4세대 방사광가속기에는 100 PPM급의 클라이스트론 펄스전압 안정도가 요구된다. 이러한 안정도는 PFN(pulse forming network)에 충전되는 전압을 얼마나 정밀하게 제어하는가에 따라서 결정된다. PFN의 최종운전 전압은 deQing circuit에 triggering되는 시점에 따라서 결정된다. DeQing trigger system은 PFN의 충전전압과 기준전압을 비교하여 충전전압이 기준전압보다 커지는 시점에서 charging choke(충전 쵸크)의 2차에 구성된 deQing 회로의 SCR를 트리거 시켜서 충전 쵸크 1차와 2차의 권선비율이 25:1인 충전 쵸크의 2차를 단락시켜 1차에 흐르는 전류를 2차로 빼주어서 PFN 커패시터에 더 이상 충전되지 않게 하는 구조로 되어있다. DeQing circuit에 triggering되는 시점을 정밀하게 제어하기 위하여 PFN 충전전압을 미분하여 그 출력전압에 비례하여 트리거 출력을 지연시키는 기능과 analog 신호를 digital 신호로 변환하는 기능을 사용하였다. 이 논문에서는 deQing 시스템에 관련된 회로 및 시험결과에 대하여 설명하고자 한다.

  • PDF

모듈레이터의 지령충전을 위한 고전압 반도체 스위치 개발 (Development of a High Voltage Semiconductor Switch for the Command Charging o)

  • 박성수;이경태;김상희;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2067-2069
    • /
    • 1998
  • A prototype semiconductor switch for the command resonant charging system has been developed for a line type modulator, which charges parallel pulse forming network(PFN) up to voltage of 5 kV at repetition rates of 60 Hz. A phase controlled power supply provides charging of the 4.7 ${\mu}s$ filter capacitor bank to voltage up to 5 kV. A solid state module of series stack array of sixe matched SCRs(1.6 kV, 50 A) is used as a command charging switch to initiate the resonant charging cycle. Both resistive and RC snubber network are used across each stage of the switch assembly in order to ensure proper voltage division during both steady state and transient condition. A master trigger signal is generated to trigger circuits which are transmitted through pulse transformer to each of the 6 series switch stages. A pulse transformer is required for high voltage trigger or power isolation. This paper will discuss trigger method, protection scheme, circuit simulation, and test result.

  • PDF

GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구 (A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System)

  • 김성주;장석훈;조국희
    • 한국안전학회지
    • /
    • 제33권2호
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.