• Title/Summary/Keyword: pulse type excitation

Search Result 24, Processing Time 0.029 seconds

Analysis of Xenon Flash Lamp Discharge System for Laser Excitation (레이저 발진용 세논기체 섬광관의 방전계통해석)

  • 김영권;이문기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.25-30
    • /
    • 1968
  • The characteristics of single mesh discharge circiut for Xenon flashlamp has been analysised in detail. Since flashlamp voltage characteristics is linear in time, though nonlinear in current, the nonliear differential equation , for this system has beens solved by the analog computer. Also for given lamp type, energy input, pulse duration, and pulse shape factor, the inductance, capacatince and operating voltage were discussed.

  • PDF

Force Characteristic Analysis of Airflow Type Linear Pulse Mortor by Permeance Method (패미언스법에 의한 공압 부상형 리니어 펄스모터의 힘 특성 해석)

  • 김일남;백수현;윤신용
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.160-169
    • /
    • 1999
  • Linear pulse rootor (LPM) be suitable a field where smooth linear rootion of high precision is required, because it's structured with minute teeth pitch in airgap of between and stator and roover(forcer). Force and position of LPM are effected sensitively by the teeth pitch, air gap, permanent magnet and excitation current. So, LPM is much important to analyze the force characteristics. llis paper was awlied to perrreance roothed for force calculation at airgap. The airgap of LPM is maintained from the pressure generated by an air-bearing. Simplified airflow and permeance methods will be used to calculate the air gap under static conditions. Therefore, the maximum available force is then derived using the coenergy method with variable air gap, also normal force and linear thrust was acquired from variable minute displacement 1[mm]. 1[mm].

  • PDF

Speed Control of DC Motor for Roller Type Seeder (롤러형 파종기 구동용 직류모터의 회전속도 제어)

  • 이중용;김유용;박상래
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.351-358
    • /
    • 2000
  • This study was conducted to develop a speed control system of a DC motor which drove a barley seeder mounted on a combine harvester. Barley seeder mounted on a combine has been known to reduce labor and cost of barley cultivation. However, development of the seeder has been unsuccessful because the combine, a dedicated rice and barley harvester has not enough space and proper power take-off for barley seeder. To develop a barley seeder, small powered motor speed controller was required. A proximity sensor for detecting working speed of the combine and a programmable one board microprocessor was used to develope a control system. Motor parameters and motor constant, relationship between seeding rate, motor speed, groove volumes of a tested roller, torque were measured. The proximity sensor sent a frequency signal to the microprocessor. In laboratory experiments, the excitation voltage of the motor was shown not to be proportional to the size of pulse width (duty ratio). A table transforming frequency signal, that represented for working speed to proper pulse width was developed from seeding rate experiments. However, seeding rate at low frequency signal was not proportional to the working speed. Seeding rate control proportional to the frequency signal was achieved by shifting of the frequency signal.

  • PDF

Dynamic Characteristics of ALA and Active Vibration Control Experiment (ALA 동적 특성 및 능동진동제어 실험)

  • Lee, Han-Dong;Kwak, Moon-K.;Kim, Jeong-Hoon;Song, Yoon-Chul;Shim, Jae-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.781-787
    • /
    • 2009
  • This research is concerned with the application of the active linear actuator to the active vibration control of structure. The active linear actuator will be mounted on the sub-frame so that it can cancel the excitation transferred from the engine. Accelerometer mounted on the sub-frame detects the vibration and its signal is fed into the DSP controller where the control algorithm is installed. The output of the DSP controller is connected to the driver which amplifies the DSP output. In general, the pulse width modulation power amplifier is used to drive the voice-coil type actuator. This study shows the dynamic characteristics of the active linear actuator and active vibration control experimental results.

SRM drive system with reduced harmonics and improved power factor (고조파감소 및 역률개선을 위한 SRM 구동시스템에 관한 연구)

  • 신규재;권영안;임근희
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.151-157
    • /
    • 1997
  • Switched relutance motor(SRM) has the advantages of simple structure, low rotor intertia, and high power rate per unit volume. However, SRM has the disadvantages of high current harmonics, and low power factor because of the discontinuous excitation of pulse type. The harmonics brings about the distortion and loss of power system, and brings about the incorrect opertion of electronic system. This paper investigates the SRM drive system with the reduced harmonics and improved power factor. The system consists of the switching power converter with poewr factor correction(SPC-PFC), DC/DC converter and 3-phase inverter. The performances in the proposed system are verified through the simpuation and experiment.

  • PDF

Dynamic characteristics of ALA and Active Vibration Control Experiment (ALA 동적 특성 및 능동진동제어 실험)

  • Lee, Han-Dong;Kwak, Moon-K.;Kim, Jeong-Hoon;Song, Yoon-Chul;Shim, Jae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.639-644
    • /
    • 2009
  • This research is concerned with the application of the active linear actuator to the active vibration control of structure. The active linear actuator will be mounted on the sub-frame so that it can cancel the excitation transferred from the engine. Accelerometer mounted on the sub-frame detects the vibration and its signal is fed into the DSP controller where the control algorithm is installed. The output of the DSP controller is connected to the driver which amplifies the DSP output. In general, the pulse width modulation power amplifier is used to drive the voice-coil type actuator. This study shows the dynamic characteristics of the active linear actuator and active vibration control experimental results.

  • PDF

LPM Control by $\mu$-Step drive method ($\mu$-Step 구동방식에 의한 LPM의 제어)

  • Baek, S.H.;Youn, S.Y.;Kim, Y.;Im, T.B.;Kim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.287-289
    • /
    • 1995
  • In this paper, We applied the $\mu$-stepping method on the Phase Excitation Sequence of Hybrid type LPM. Linear Pulse Motor can opeate in an open loop control as an effective positioning actuator. PWM driver was used for low power loss and automatically adjusted voltage at rate current. Finally we find that through the position-velocity for timing Triangular and Trapezoidal Profile are very affected by velocity and acceleration parameter.

  • PDF

Detection of Impulse Signal in Noise Using a Minimum Variance Cepstrum -Application on Faults Detection in a Bearing System (최소 분산 캡스트럼을 이용한 노이즈 속에 묻힌 임펄스 검출 방법-베어링 결함 검출에의 적용)

  • 최영철;김양한
    • Journal of KSNVE
    • /
    • v.10 no.6
    • /
    • pp.985-990
    • /
    • 2000
  • The signals that can be obtained from rotating machines often convey the information of machine. For example, if the machine under investigation has faults, then these signals often have pulse signals, embedded in noise. Therefore the ability to detect the fault signal in noise is major concern of fault diagnosis of rotating machine, In this paper, minimum variance cepstrum (MV cepstrum) . which can easily detect impulse in noise, has been applied to detect the type of faults of ball bearing system. To test the performance of this technique. various experiments have been performed for ball bearing elements that have man made faults. Results show that minimum variance cepstrum can easily detect the periodicity due to faults and also shows the pattern of excitation by the faults.

  • PDF

Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger (전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가)

  • Kang, Hyung-Sub;Hong, Young-Pyo;Lee, In-Ho;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.558-566
    • /
    • 2017
  • In this study, we developed an electron-emission OH radical generator for waste water treatment. The stability of the circuitry was ensured by implementing stable pulse waves with a MOSFET and reducing the momentary current rise. The OH radical generator uses a high-voltage and low-current discharger. The performance of the device was evaluated experimentally, which showed that it is possible to produce a stable and uniform pulse waveform for the drain current of the power MOSFET, which is connected to the input side of an AC multiplying converter through negative feedback circuitry with CR-snubber architecture. It was also possible to reduce the excitation current of the converter and improve the stability of the oscillation circuit. In addition, the generator can generate hydroxyl radicals stably. The bactericidal activities were also evaluated, and the germicidal power for E. coli, S. aureus, and S. flexneriwas improved by 99.9% or more after 60 minutes.

High Efficacy AC-PDP toward 10 lm/W

  • Choi, Kyung-Cheol;Lee, Seung-Tae;Shin, Nam-Hoon;Lee, Seong-Min;Song, Sang-Cheol;Yun, Jin-Bhum;Shin, Bhum-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.7-12
    • /
    • 2006
  • The high efficacy concept, featuring in this study an auxiliary electrode and a 200 ${\mu}m$ coplanar gap, is applied to AC-PDPs with a stripe - type and a closed - type barrier rib, respectively. The roles of the pulses applied to the auxiliary electrode create additional excitation during the sustain period and reduce a discharge current that flows into the display cells. The efficacy of the proposed panel with the closed barrier rib has maximum values when the auxiliary pulse voltage is 50 volts and 80 volts for the Ne+4%Xe and Ne+20%Xe gas-mixtures, respectively. The maximum luminous efficacy is more than 10 lm/W in terms of the measurement of the discharges in VGA resolution ($540{\mu}m{\times}720{\mu}m$) and the green cells.

  • PDF