• Title/Summary/Keyword: pulse pattern

Search Result 426, Processing Time 0.028 seconds

SEDATION EVALUATION USING BIS INDEX ASSESSMENT WITH AND WITHOUT THE ADDED SUBMUCOSAL MIDAZOLAM (점막하 Midazolam의 병용투여 시 BIS 분석을 이용한 진정 평가)

  • Lee, Young-Eun;Park, Mi-Kyung;Kim, So-Young;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • The aim of this study was to examine the difference of the depth of sedation using the Bispectral index assessment with and without the added submucosal Midazolam to oral Chloral hydrate and Hydroxyzine for pediatric patients. Twenty seven sedation cases were performed in this study Selection criteria included good health(ASA I), 2 to 6 years of age, the need for sedation to receive dental treatment including anesthesia, and restorative procedure over at least two teeth. Patients were randomly classified into one group taking oral Chloral hydrate(60 mg/kg) and Hydroxyzine(1 mg/kg) and the other group recieving Chloral hydrate(60 mg/kg), Hydroxyzine(1 mg/kg) and submucosal Midazolam(0.1 mg/kg). Nitrous Oxide(50%) was used for both group during sedation. Patients were monitored using a pulse oximeter and a Bispectral monitor. A behavior scale was rated as quiet(Q), crying(C), movement(M), or struggling(S) every 2 minutes watching a recorded videotape. Analysis showed a significant difference in mean Bispectral index and SD during sedation across two groups(P<0.001). The group of patients injected with submucosal Midazolam in addition to oral Chloral hydrate and Hydroxyzine showed a lower mean Bispectral index and a narrower SD. PR and SpO2 for both groups remained within the normal values. Submucosal Midazolam improved the sedation quality by deepening sedation depth without compromising safety and enabled the sedation pattern to be kept more stable.

  • PDF

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Comparison of Karasek's Job Content Questionnaire and Korea Occupational Stress Scale (Karasek의 Job Content Questionnaire와 Korea Occupational Stress Scale의 비교 연구)

  • Lee, Jong-Bin;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.72-78
    • /
    • 2015
  • According to the report of the WHO, workers have been exposed to much job strain such as job load, responsibility, role, interpersonal conflict etc. In Korea, studies on job strain started to become active from 1990s and now hundreds of studies are actively under going or publishing so that the studies are contributing to development and improvement of job strain. Representative measurement models of job strain are Job Strain Model of Karasek, Job Stress Model of NOISH, Korea Occupational Stress Scale, JSQ(Job Stress Questionnaire), K-OSI(Korea Version of Occupational Stress Inventory) etc. (Lee Kwan-Suk, 2012 ; KOSHA, 2003). Among them, Job Strain Model of Karasek had been loved by many researchers of job strain before Korea Occupational Stress Scale was developed. Job Strain Model of Karasek had been fitted to Korean style and then, used to analyze job strain of Korean people so that this Scale highly contributed to seeking relationship with cardiovascular disease, musculoskeletal disease caused by job, smoking, drug, alcohol poisoning, and pulse(Lee Kwan-Suk, 2012). But as this Model was studied and developed based on foreign culture and life pattern, a model fit to Korea was developed to measure job strain for Korean people, which is Korea Occupational Stress Scale now most frequently used in measuring job strain. Accordingly, after this study made questionnaire survey about same population using the two methods used most frequently in measuring job strain, the study investigated what features appeared, what correlations appear between two models, and comparatively analyzed characteristics each independent and dependent variable. Based on this, the study aimed to exactly express job strain of Korean people. The subjects of the study were a population of 233, and Karasek's Questionnaire and KOSS's Questionnaire were surveyed at the same time. The results were analyzed by statistical program to obtain significant difference between two models. Four particular groups were divided with Job Strain Model of Karasek and the four particular groups were measured with Korea Occupational Stress Scale. And job strain come from combination of two models was measured, with which new comparative analysis method was suggested.

Higher Order Shimming for Ultra-fast Spiral-Scan Imaging at 3 Tesla MRI System (3 Tesla MRI 시스템에서 초고속 나선주사영상을 위한 고차 shimming)

  • Kim, P.K.;Lim, J.W.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2007
  • Purpose: To acquire high-resolution spiral-scan images at higher magnetic field, high homogeneous magnetic field is needed. Field inhomogeneity mapping and in-vivo shimming are important for rapid imaging such as spiral-scan imaging. The rapid scanning sequences are very susceptible to inhomogeneity. In this paper, we proposed a higher-order shimming method to obtain homogeneous magnetic field. Materials and Methods: To reduce measurement time for field inhomogeneity mapping, simultaneous axial/ sagittal, and coronal acquisitions are done using multi-slice based Fast Spin echo sequence. Acquired field inhomogeneity map is analyzed using the spherical harmonic functions, and shim currents are obtained by the multiplication of the pseudo-inverse of the field pattern with the inhomogeneity map. Results: Since the field inhomogeneity is increasing in proportion to the magnetic field, higher order shimming to reduce the inhomogeneity becomes more important in high field imaging. The shimming technique in which axial, sagittal, and coronal section inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the imhomogenity map is applied. The proposed technique is applicable to a localized shimming as well. High resolution spiral-scan imaging was successfully obtained with the proposed higher order shimming. Conclusion: Proposed pulse sequence for rapid measurement of inhomogeneity map and higher order shimming based on the inhomogeneity map work very well at 3 Tesla MRI system. With the proposed higher order shimming and localized higher order shimming techniques, high resolution spiral-scan images are successfully obtained at 3 T MRI system.

  • PDF

Effects of Alcohol on Neurocognitive Function, Psychomotor Performance and Subjective Response in Koreans with Different ALDH2 Genotypes (한국인에서 Aldehyde Dehydrogenase 2 유전자 변이가 알코올의 신경인지 기능, 정신운동성 수행 및 주관적 반응에 미치는 영향)

  • Shin, Il-Seon;Yoon, Jin-Sang;Kim, Hyun;Yoon, Bo-Hyun;Lee, Hoon;Jung, Jae-Sung;Lee, Hyung-Yung
    • Korean Journal of Biological Psychiatry
    • /
    • v.6 no.2
    • /
    • pp.176-188
    • /
    • 1999
  • Objective : The purpose of this study was to evaluate the effects of alcohol on neurocognitive function, psychomotor performance and subjective response in healthy Korean adults with different ALDH2 genotypes. Method : A total of 24 males, half with active $ALDH2^*1/2^*1$ and the other with inactive $ALDH2^*1/2^*2$, was selected through genotyping using restriction fragment length polymorphism. In a double-blind, placebo-controlled cross-over design, each subject consumed 0.5g/kg dose of alcohol, given as a mixture of 40% vodka and orange juice, and placebo(orange juice) on two separate occasions on an average of weekly intervals. The blood alcohol concentrations(BACs) were measured using a breath analyzer at baseline and at 30, 60 minutes after drinking. P300s were measured at baseline and at 30 minutes after alcohol and placebo intake. Vital signs and psychomotor performance[Critical Flicker Fusion Threshold(CFFT), Choice Reaction Time (CRT), Digit Symbol Substitution(DSS)] were measured at baseline and at 60 minutes after alcohol and placebo intake. Subjective responses were measured at the end of the study. The statistical analysis focused on whether there were any differences between groups with different ALDH2 genotypes. Results : The major results are as follows. 1) BACs in the inactive group were overall equivalent to those in the active group. Only in terms of time, BACs were significantly higher overall at 30 minutes than at 60 minutes after alcohol intake. 2) Pulse rates were significantly increased after alcohol intake compared with placebo, and the increase was greater in the inactive than in the active group. 3) P300 latencies in leads Fz(frontal), Cz(cental) and Pz(parietal) were significantly increased after alcohol intake compared to placebo, and the increase was greater in the inactive than in the active group. P300 amplitudes in leads Cz and Pz were significantly decreased overall after alcohol intake compared to placebo. 4) Compared with placebo, alcohol produced significant effect on the psychomotor performance : impairment in the inactive group, improvement in the active group. 5) Compared with placebo, alcohol significantly induced a negative or an intense effect on the subjective responses in the inactive group, but little negative and even a somewhat positive effect in the active group. Conclusions : These results suggest that ALDH isozyme variance might be an important factor to determine the effects of acute dose of alcohol on the various psychobehavioural functions and also to determine the alcohol use pattern and to predict the future development of alcohol overuse and/or abuse.

  • PDF

Determination of Proper Application Rate of Curing Compound for Cement Concrete Pavement (콘크리트 포장 양생제의 적정살포량 결정 연구)

  • Kim, Jang-Rak;Suh, Young-Chan;Ahn, Sung-Soon
    • International Journal of Highway Engineering
    • /
    • v.7 no.2 s.24
    • /
    • pp.45-55
    • /
    • 2005
  • It is known that the Q/C(Quality Control) in the early age of portland cement concrete(PCC) pavement gives a huge effect on long term pavement performance. Thus, many studies regarding the construction of PCC pavement have focused on how to assure construction quality at the early age stage. Curing is one of the most important factor in Q/C of PCC pavement. Membrane curing that protects the evaporation of moisture by placing an impermeable layer on the slab surface is the most common practice for curing the PCC pavement. In order to improve the membrane curing practice, the rate of curing compound should be optimized. However, the optimum rate of curing compound considering Korean weather and environmental conditions has not been specified in the pavement construction specifications. In this study, a proper application rate was recommended in terms of minimizing evaporation with several full-scale tests where various rates of curing compound have been applied. Four test sites on the expressway were enlisted during the summer of 2002 and 2003. Application rates tested were in the range of $0. The rate of evaporation, the temperature pattern of the slab and the pulse velocity of concrete surface have been monitored at each test construction. The result from this study showed that the rate of current construction was approximately $160ml/m^2$ and that approximately $400ml/m^2$ of curing application was recommended as the proper rate for minimizing the moisture evaporation.

  • PDF

Study of Noncontact Condition Diagnosis on Painting with Terahertz Waves (테라헤르츠파를 이용한 회화문화재 상태진단 적용연구)

  • Baek, Na Yeon;Kang, Dai Ill;Ha, Tae Woo;Sim, Kyung Ik;Lee, Ho Won;Kim, Jae Hoon;Lee, Han Hyoung
    • Journal of Conservation Science
    • /
    • v.32 no.2
    • /
    • pp.235-247
    • /
    • 2016
  • Conventional imaging techniques such as ultraviolet, infrared, and X-ray are used mainly to diagnose the damaged parts of the painted cultural assets in Korea. These techniques, however, have limits in diagnosing damages of interlayer parts. We have performed and extensive study on the applicability of Terahertz(THz) analysis technique, introduced recently to this field of study on cultural properties in Korea, to diagnose painted cultural assets. The specimens, produced to imitate the damage types of Korean painted properties, were analyzed over their painting, supporting, and backing layers by terahertz pulse imaging technique. The analyzed results provided information about the cracks, the separated areas, and the separated distances between layers on the specimens. Our research, then, was extended to real painted cultural remains, Birojana Sam-shin Gwebul-do at Bongseon Temple in Namyang-ju, Korea National Treasure Number 1792, through which we have obtained 3D information about the extent and pattern of damages to the asset. These results demonstrate that terahertz 3D imaging technique has the capability of noncontact 3D diagnosis on painted cultural properties.

Review of Failure Mechanisms on the Semiconductor Devices under Electromagnetic Pulses (고출력전자기파에 의한 반도체부품의 고장메커니즘 고찰)

  • Kim, Dongshin;Koo, Yong-Sung;Kim, Ju-Hee;Kang, Soyeon;Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.37-43
    • /
    • 2017
  • This review investigates the basic principle of physical interactions and failure mechanisms introduced in the materials and inner parts of semiconducting components under electromagnetic pulses (EMPs). The transfer process of EMPs at the semiconducting component level can be explained based on three layer structures (air, dielectric, and conductor layers). The theoretically absorbed energy can be predicted by the complex reflection coefficient. The main failure mechanisms of semiconductor components are also described based on the Joule heating energy generated by the coupling between materials and the applied EMPs. Breakdown of the P-N junction, burnout of the circuit pattern in the semiconductor chip, and damage to connecting wires between the lead frame and semiconducting chips can result from dielectric heating and eddy current loss due to electric and magnetic fields. To summarize, the EMPs transferred to the semiconductor components interact with the chip material in a semiconductor, and dipolar polarization and ionic conduction happen at the same time. Destruction of the P-N junction can result from excessive reverse voltage. Further EMP research at the semiconducting component level is needed to improve the reliability and susceptibility of electric and electronic systems.

The Development of Pc Based EGG-NIBP Patient Monitor (PC 기반의 심전도-비관혈식 혈압 환자감시장치의 개발)

  • 김남현;김경하;주기춘;라상원;송광석;한민수;김성민;이건기;최태영
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.461-469
    • /
    • 1999
  • In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.

  • PDF

A Study and Design of Beam Scanning Array Antenna using IR-UWB (IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구)

  • Kim, Keun-Yong;Kang, Eun-Kyun;Kim, Jin-Woo;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.194-201
    • /
    • 2014
  • This paper is able to be solved by improving degradation in multi-path environment by adjust beam pattern angle through modifying pulse phase of each antennas by using TRM (Transmitter Receiver Module). Beam Scanning Array Antenna, which is transmitter/receiver that improves degradation in multi-path environment without any signal distortion, is designed and manufactured. Beam Scanning Array Antenna should be able to send/receive signal at the antenna's longitudinal part without distortion and should not influences other systems. Also, it should include target detecting ability by beam steering.Dispersion characteristic of Beam Scanning Antenna, which is designed, is analysed by using fidelity, and steering and radar resolution performance is verified by using $1cm{\times}1cm$ sized target. To manufacture Beam Scanning Array Antenna, control board and GUI, which is able to control Vivaldi Antenna for IR-UWB, Tri-Band Wilkinson power divider, and TRM (Transmitter Receiver Module), is designed. Throughout this research, developed Beam Scanning UWB Array Antenna system is adoptable for radar application field. and time domain analysis techniques by using network analyser made the antenna characteristics analysis for setting up antenna more accurate. In addition, it makes beam width checking without difficulties.