• 제목/요약/키워드: pulse magnetic field

검색결과 151건 처리시간 0.025초

Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices

  • Lee, Sang-Suk;Kim, Gi-Wang;Ahn, Myung-Cheon;Park, Young-Seok;Choi, Jong-Gu;Choi, Sang-Dae;Park, Dal-Ho;Hwang, Do-Guwn;Yoon, Hyung-Rho
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.721-726
    • /
    • 2007
  • The study relates to achievement and analysis of 3-dimensional spatial pulse wave archived by a spatially arterial pulse diagnostic apparatus (SAPDA), wherein a pulse sensing part array consists of multiple hall devices and is located over a skin contacting part which consists of a magnetic material. When a radially arterial pulse is transferred to the magnetic material, which is contacted skin that results in changes in a magnetic field of the lower part of the pulse sensing part array, the changes in a magnetic field can be detected by the commercial Hall semiconductor device of the pulse sensing part array. Finally, according to development of SAPDA, the 3-dimensionally arterial pulse waveform can be measured noninvasively by detecting the changes of the magnetic field.

Acceleration of Cell Proliferation and Gene Expression in Human Chondrosarcoma Cells Stimulated by Strong Pulse Magnetic Field

  • Shin, Sung Chul;Chung, Eui Ryong;Hwang, Do Guwn
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.14-20
    • /
    • 2013
  • For the treatment of osteoarthritis, pulsed electromagnetic field stimulus has been suggested as a useful therapeutic method in rehabilitative medicine. Most studies have been performed under low-frequency and low-energy to find out biological properties for stimulating chondrocyte with pulsed magnetic field. In this study, the effect of strong pulse magnetic field on the human chondrosarcoma cells (SW-1353) has been investigated by means of cell counting, morphologies, and gene expression of cartilage extracellular matrix genes. The SW-1353 cells were exposed under the field intensities of 270, 100, 55, 36, and 26 mTesla during 6 hours a day in 5 consecutive days. The pulse magnetic field with an LRC oscillating signal has the pulse width of 0.126 msec and stimulation period of 1 sec. For the 270 and 100 mTesla stimulation, the cell proliferation significantly increased in 21-24% as compared with the non-stimulated cells. Gene expression of cartilage extracellular matrix genes (ACAN, COMP and COL2A1) was assayed by quantitative real time-PCR method. The ACAN gene expression showed a significant brightness, which means the increase on gene expression, compared with the non-stimulated cells. Our results suggest that the strong pulse magnetic field stimulation can be utilized to accelerate cell proliferation and gene expression on human chondrosarcoma cells.

Low Writing Field on Perpendicular Nano-ferromagnetic

  • Wibowo, Nur Aji;Rondonuwu, Ferdy S.;Purnama, Budi
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.237-240
    • /
    • 2014
  • For heat-assisted magnetic recording, magnetization reversal probabilities of nano-Pt/MnSb multilayer film with perpendicular magnetic anisotropy under thermal pulse activation were investigated numerically by solving the Landau-Lifshift Gilbert Equation. Magnetic parameters of nano-Pt/MnSb multilayer were used with anisotropy energy of $3{\times}10^5$ erg/cc and saturation magnetization of 2100 G, which offer more than 10 y data stability at room temperature. Scheme of driven magnetic field and thermal pulse on writing mechanism was designed closely to real experiment. This study found that the chosen material is potential to be used as a high density magnetic storage that requires low writing field less than two-hundreds Oersted through definite heating and cooling interval. The possibility of writing data with a zero driven magnetic field also became an important result. Further study is recommended on the thickness of media and thermal pulse design as the essential parameters of the reversal magnetization.

유한 요소법을 이용한 맥진 파형의 자기장 변화 분석 (Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method)

  • 박태영;이상석
    • 한국자기학회지
    • /
    • 제24권3호
    • /
    • pp.90-96
    • /
    • 2014
  • 요골동맥의 움직임에 따라 손목의 "관" 위치에 놓인 영구자석이 요동함으로 자기장의 변화를 생성하였다. 맥동에 의존하는 자기장을 감지하는 홀소자가 구비된 집게형맥진기의 출력신호인 맥진파형 특성을 분석하였다. 유한요소법으로 전산모사한 자기장 파형과 실제 맥진 파형의 시간 특징점들은 거의 일치하였다. 한 개의 원통 소형 영구자석의 자기장 분포의 변화를 감지하는 홀소자 집게형맥진기 시뮬레이터를 제작하여 재현성과 유효성 있는 한방진단기기로 활용하는 기틀을 마련하였다.

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

Introduction of the Magnetic Pulse Compressor (MPC) - Fundamental Review and Practical Application

  • Choi, Jae-Gu
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.484-492
    • /
    • 2010
  • Magnetic switch is a kind of saturable inductor, which utilizes nonlinearity of the magnetization curve of ferromagnetic materials. The right understanding of the saturation phenomena, magnetic properties, voltage-time product, and switching characteristics of the magnetic switch is essential in designing the magnetic pulse compressor (MPC). In this paper, the historical background of research on the MPC, fundamental physical properties of the magnetic switches, and application fields of the MPC are presented. Further, an in-depth analysis of pulse compression in series and parallel MPCs is incorporated. As practical application examples, a series MPC used for water treatments and a parallel MPC used for pulsed electric field (PEF) inactivation of bacteria are cited.

전.자계상의 전원장치변화에 따른 비열방전 플라즈마의 $SO_2$와 CO가스 제거특성 ($SO_2$ and CO Removal Characteristics in Various Applied Voltage of Nonthermal Discharge Plasma in a Crossed DC Magnetic Field)

  • 이근택;금상택;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권3호
    • /
    • pp.215-220
    • /
    • 1999
  • $SO_2$and CO gas removal characteristics of a wire-to-cylinder type nonthermal discharge plasma reactor in various applied voltage (-dc, ac, fast rising pulse and high frequency pulse) and a crossed dc magnetic field have been investigated. The experiment has been emphasized on the oxidizing characteristics of $SO_2$ and CO gas by $O_3$ and the applying of a crossed magnetic field, which would induce the cyclotronic and drift motions of electrons making the residual time longer in the removal airgap space. And it also would enhance the energy of electrons and the electrophysicochemical actions to remove the pollutant gases effectively. It is found thatthe corona onset voltage and the breakdown voltage were decreased with increasing the crossed magnetic field and decrease initial fed $SO_2$and CO concentration. As a result, a higher ozone generation and $SO_2$ and CO gas removal rate of 20[%] can be obtained with -dc, ac and fast rising pulse corona discharges in the crossed dc current-induced magnetic field. But high frequency pulse didn't show effect in applying of a crossed magnetic field.

  • PDF

펄스자기장 자극에 의한 손의 적혈구 형태학적 변화 (Change in Rouleau Formation of Red Blood Cells by Pulse Magnetic Field Stimulus in the Hand)

  • 황도근
    • 한국자기학회지
    • /
    • 제24권1호
    • /
    • pp.28-33
    • /
    • 2014
  • 최대 0.27 T 세기와 0.102 ms 펄스시간을 가지는 자기장 자극시스템을 이용하여 손에 인가한 후에 생혈액 분석을 통해 말초혈관에 흐르는 적혈구의 형태학적 변화를 조사하였다. 펄스자기장 자극 전 피실험자의 적혈구는 10여개 이상씩 서로 붙어있는 연전형성(連錢形成, rouleau formation)이 일어나서 적혈구의 움직임이 느려졌으나, 손에 10분간 자기장 인가한 후에 연전형성이 되었던 적혈구가 대부분 떨어져서 독립적인 움직임을 보이면서 운동이 활발해졌다. 또한 왼쪽 손에 펄스자기장을 10분 자극한 후에 자극받지 않은 오른쪽 손에서 채혈했을 때에도 연전현상이 똑같이 개선되었다. 이는 혈류흐름에 의해 체내에 모든 적혈구의 연전현상이 개선된 것으로 판단할 수 있다.

펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구 (Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor)

  • 최우진;이준탁
    • 전기학회논문지
    • /
    • 제62권3호
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.