• 제목/요약/키워드: pulse height

검색결과 193건 처리시간 0.027초

어레이 압저항 센서 장착 맥진기의 고혈압 맥파 특성 (Characteristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor)

  • 최용석;김경요;황승연;김종열;이시우;김현희;주종천
    • Korean Journal of Acupuncture
    • /
    • 제24권3호
    • /
    • pp.105-116
    • /
    • 2007
  • Objectives : This study was performed to determine whether a pulse analyzer using array piezoresistive sensor was useful to characterize the variables of pulse wave of hypertentive patients (HT) , compared with those of healthy subjects. Methods : One hundred twenty two subjects participated in this study. Sixty nine subjects had hypertension and fifty three subjects had no specific history or disease associated with hypertension. We used automatic pulse analyzer with array piezoreslstive sensor. Results : Calibrated in Chon, no specific differences was between HT group and the healthy group. Calibrated in Gwan. sum of pulse pressure (SPP) of HT group was higher than that of the healthy group. Calibrated in Cheek, mean of height of main peak (Mm) and height of main peak (h1) of HT group were higher than those of the healthy group. Conclusions : Pulse analyzer was useful to determine the risk degree or development possibility of hypertension.

  • PDF

초음파 펄스 에코 패턴으로 용접 결함 식별 방법 연구 (Study of the Weld Defects Identification Method by Ultrasonic Pulse Echo Patterns)

  • 김원중
    • 한국산학기술학회논문지
    • /
    • 제14권12호
    • /
    • pp.6114-6118
    • /
    • 2013
  • 본 연구에서는 초음파 탐상시험의 펄스 반사법으로 각각 용접결함에 따른 초음파 펄스파형모형을 연구하였다. 균열은 예리하고 선명한 신호들을 발생한다. 탐촉자를 결함주위로 이동하면 에코높이는 변한다. 긴 균열에서는 탐촉자가 결함 주위를 원형으로 목돌림주사법을 사용하여 탐상하면 에코높이는 급격히 감소한다. 그 에코 봉우리는 바늘과 같이 얇고 날카롭다. 기공은 단일 결함으로부터 발생하는 에코는 예리하고 선명하다 하지만 집단의 기공들은 다수의 반사들이 중첩되고 트레이스가 들쭉날쭉한 에코가 발생한다. 슬래그 개재물은 크랙과 슬래그 결함위치에서 각각 목돌림 주사법을 사용하여 탐상하면 그 에코형상은 어느 정도 차이를 볼 수 있었다. crack은 그 에코높이가 급격히 변하는 반면에 슬래그 개재물은 증가${\rightarrow}$감소${\rightarrow}$증가${\rightarrow}$감소된다. 또한 다수 밀집된 기공의 위치에서 결함은 대표적 에코형상과 같은 잡다한 에코형상은 슬래그에서는 볼 수 없었다. 용입불량은 결함의 에코형상은 크랙과 같이 날카롭고 예리하게 나타났고, crack과 비슷한 에코형상은 갖고 있었다.

방사선 펄스의 고안정 계측 및 분석기술 개발 (Development of High Stable Instrumentation and Analytic Techniques for Radioactive Pulses)

  • 손원진;김일권;한주섭;송재용;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.465-468
    • /
    • 2001
  • An objection of this study is to develop a high stable analytic system of radioactive pulses. The proposed system consists of an amplifying circuit with 60dB gain, a programmable power supply unit which can generate DC voltage up to 1, 500V, and a digital signal processor. Pulse height distribution in accordance with pulse counts is important data in analyzing radioactive pulses. In this study, AD convertor (12bit, l00ns) and DSP (TMS 320C31-60) are used to analyze the pulse height, and the analytic system is designed to be operated in PC-networking.

  • PDF

Fatigue Characteristics of PZT Thin Films Deposited by ECR-PECVD

  • Chung, Su-Ock;Lee, Won-Jong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.177-185
    • /
    • 2005
  • Fatigue characteristics of lead zirconate titanate (PZT) films deposited by electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) were investigated. The fatigue characteristics were investigated with respect to PZT film thickness, domain structure, fatigue pulse height, temperature, electrode materials and electrode configurations. The used top and bottom electrode materials were Pt and $RuO_2$. In the fatigue characteristics with fatigue pulse height and PZT film thickness, the fatigue rates are independent of the applied fatigue pulse height at the electric field regions to saturate the P-E hysteresis and polarization $(P^*,\;P^A)$ characteristics. The unipolar and bipolar fatigue characteristics of PZT capacitors with four different electrode configurations $(Pt//Pt,\;Pt//RuO_2,\;RuO_2//Pt,\;and\;RuO_2//RuO_2)$ were also investigated. The polarization-shifts during the unipolar fatigue and the temperature dependence of fatigue rate suggest that the migration of charged defects should not be expected in our CVD-PZT films. It seems that the polarization degradations are attributed to the formation of charged defects only at the Pt/PZT interface during the domain switching. The charged defects pin the domain wall at the vicinity of Pt/PZT interface. When the top and bottom electrode configurations are of asymmetric $(Pt//RuO_2,\;RuO_2//Pt)$, the internal fields can be generated by the difference of charged defect densities between top and bottom interfaces.

Estimating Dense Forest Canopy Structure Using Airborne Laser Scanner Data

  • Park J. H.;Jang K. C.;Ma J. L.;Lee K. S.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.638-641
    • /
    • 2004
  • Returned laser pulse has certain relationship with vegetation canopy structure (canopy closure, height, LAI, biomass). This study attempts to analyze the characteristics of airborne laser scanner data over very dense forest canopy. Discrete pulse laser scanner data were obtained on April 25, 2004 along with digital aerial color imagery. Using forest stand maps, 14 sample stands of 7 species groups were selected and the elevations from the first and last laser return were compared. From the preliminary analysis, we found that the difference between the first and last return was higher with deciduous forest stand than in coniferous stand. Although difference between the first and the last laser returns often corresponds to tree height, it would not be the case for the forest site having very dense canopy structure.

  • PDF

소아맥진(小兒脈診)의 특성(特性)에 대한 소고(小考) (A study on The Characteristic of Traditional Pediatric Pulse Diagnosis)

  • 백유상
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.111-122
    • /
    • 2014
  • Objective : The region, observation period, figuration of pulse, pulse frequency, process of diagnosis and related diagnostic methods in traditional pediatric pulse diagnosis were studied in this article. Method : The articles related to traditional pediatric pulse diagnosis in Traditional medical classics, and analysis to the characteristics of it was done, then lastly, the principle of pulse manifestation and the meaning of application to modern times were considered. Result & Conclusion : It is difficult to catch the figuration of pediatric pulse because of dynamic change of body conditions, fast heartbeat and narrow region of pulse. Therefore, the pulse diagnosis appropriated for children have been developed and combined with the special diagnosis methods, for example, palpation of forehead and observation of index finger. The traditional pediatric pulse diagnosis is done with just one finger palpation in the period of 3 to 5 years old to identify the speed, length, size and height of pulse. The standard average of pulse frequency is 7~8 par breath in the period of 3 to 5 years old according to traditional medical classic.

마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정 (Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line)

  • 이승엽;신호섭;김남;권원현
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF

5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구 (A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

단일 및 결합형 구조의 마이크로 스트립 전송선로에서 고속 펄스 신호의 왜곡 특성 분석 (An Analysis of the Distortions of High Speed Pulse Signal on the Microstrip Lines of the Single and Coupled Structures)

  • 김기래
    • 한국전기전자재료학회논문지
    • /
    • 제15권6호
    • /
    • pp.529-534
    • /
    • 2002
  • Recently, As the higher frequency in clock of digital system being demanded and the density of circuits gets high for purpose of making light and minimizing system, the study for solution of digital signal distortion being interested. In this paper, the distortion of square pulse caused by dispersion as it propagates along a single microstrip line and crosstalk between lines on the Multi-Transmission Lines (MTL) is investigated. The dispersion and crosstalk of pulse signals is analyzed regarding to the structure of transmission line such as relative permittivity, substrate height, strip width of the microstrip line and pulse width of signal pulse.

세라믹필터 역세정을 위한 노즐 사이즈 최적화 (The optimization of nozzle size for pulse cleaning of ceramic filter)

  • 최주홍;김진형;지화창;우량;사공경민;김영애
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.796-799
    • /
    • 2007
  • In the bench scale test unit consisting of four commercial filter elements, the traces of the transient pressure around the nozzle and overpressure in the filter cavity were measured to estimate the effect of nozzle on pulse cleaning. For the given pulse cleaning system, the convergent nozzle displayed better performance than the straight one. The optimum ratio of outlet to inside diameter of convergent nozzle was determined, which minimized the pulse gas consumption and maximized the entrainment effect. The angle and height of nozzle convergent part was also optimum operational condition, which is meaningful to the industrial applying.

  • PDF