• Title/Summary/Keyword: pulse forming

Search Result 110, Processing Time 0.031 seconds

Study on Timing Characteristics of High-Voltage Pulse Generation with Different Charging Voltages

  • Lee, Ki Wook;Kim, Jung Ho;Oh, Sungsup;Lee, Wangyong;Kim, Woo-Joong;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • The time synchronization of each sub-unit of a pulsed generator is important to generate an output high-power radio frequency (RF) signal. To obtain the time synchronization between an input RF signal fed by an external source and an electron beam produced by an electric pulse generator, the influence of different charging voltages on a delay and a rise time of the output pulse waveform in the electric pulse generator should be carefully considered. This paper aims to study the timing characteristics of the delay and the rise time as a function of different charging voltages with a peak value of less than -35 kV in the high-voltage pulse generator, including a trigger generator (TG) and a pulse-forming line (PFL). The simulation has been carried out to estimate characteristics in the time domain, in addition to their output high-voltage amplitude. Experimental results compared with those obtained by simulation indicate that the delay of the output pulses of the TG and PFL, which are made by controlling the external triggering signal with respect to different charging voltages, is getting longer as the charging voltage is increasing, and their rise times are inversely proportional to the amplitude of the charging voltage.

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Complex Forming of the High-Functional Intermetallic Compound by the In Process Synthesis (In-Process합성에 의한 고기능 금속간화합물의 복합성형)

  • Han, Jung-Hyun;Park, Seong-Kab;Park, Yong-Ho
    • Journal of Powder Materials
    • /
    • v.13 no.6 s.59
    • /
    • pp.408-414
    • /
    • 2006
  • [ $MoSi_2$ ] alloys with Al, B or Nb were prepared by an advanced consolidation process that combined mechanical alloying with pulse discharge sintering (complex forming) to improve the mechanical properties. Their microstructure and mechanical properties were investigated. The $MoSi_2$ alloys fabricated by complex forming method showed very fine microstructure when compared with the sample sintered from commercial $MoSi_2$ powders. Alloys made from powders milled in Ar gas had fewer silica or alumina phases as compared to their counterparts sintered from powders milled in air. In densification of the sintered body, addition of B was more effective than Al or Nb. Both Victors hardness and tensile test indicated that the alloy fabricated by the complex forming method showed better properties than the sample sintered from commercial $MoSi_2$ powders. The Al added alloy sintered from the powders milled in air had the superior mechanical properties due to the suppression of $SiO_2$ and formation of fine $Al_2O_3$ particles.

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Development of an Impulse Electromagnetic Wave Generator having Rise time of Pico Second (Pico second 기립시간의 충격 전자기파 발생기의 개발)

  • Kim, Young-Bae;Lee, Hong-Sik;Jung, Sun-Shin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.12
    • /
    • pp.597-600
    • /
    • 2006
  • When the energy of the nanoseconds high voltage pulse with hundreds picoseconds of the pulse rise time is emitted into the free space via an antenna, an ultra wide band electromagnetic wave is generated. This electromagnetic wave is expected to be used in transmitting vast amount of informations to far distance, high performance radars, post-packaging pasteurization of food, the detection of underground buried objects, searching of underground water veins or caves, the treatment of waste water or polluted gases and so forth. Additionally, this technology can be used in EMI(electromagnetic interference) evaluation of measuring instruments or printed circuit boards.

A study on development of bipolar metal surface anodizing equipment using H-bridge (H-브리지를 이용한 양극성 금속표면 양극산화장치 개발에 관한 연구)

  • Yang, Keun-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.355-362
    • /
    • 2011
  • In this paper, we developed the equipment to forming the insulation film which there are operated an electrolysis principles in particular solution. In the earlier, there are supplied the anode by unipolar voltage with pulse, in this paper, there are supplied the anode by bipolar voltage with pulse, alternately. And then, we examinate the system that there are developed the bipolar anodizing equipment using H-bridge. There are modulated pulse width for the variable current. In the results, we obtained the results of the uniform film surface that compared with the unipolar anodizing.

Comparative study of the pulse shape discrimination (PSD) performance of pixelated stilbene and plastic scintillator (EJ-276) arrays for a coded-aperture-based hand-held dual-particle imager

  • Jihwan Boo ;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1677-1686
    • /
    • 2023
  • As the demand for the detection of special nuclear materials (SNMs) increases, the use of imaging instruments that can sensitively image both gamma-ray and neutron signatures has become necessary. This study compared the pulse shape discrimination (PSD) performance of gamma/neutron events when employing either a pixelated stilbene or a plastic (EJ-276) scintillator array coupled to a silicon photomultiplier (SiPM) array in a dual-particle imager. The stilbene array allowed a lower energy threshold above which neutron and gamma-ray events can be clearly distinguished. A greater number of events can, therefore, be used when forming both gamma-ray and neutron images, which shortens the time required to acquire the images by nearly seven times.

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

TSV Filling Technology using Cu Electrodeposition (Cu 전해도금을 이용한 TSV 충전 기술)

  • Kee, Se-Ho;Shin, Ji-Oh;Jung, Il-Ho;Kim, Won-Joong;Jung, Jae-Pil
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.11-18
    • /
    • 2014
  • TSV(through silicon via) filling technology is making a hole in Si wafer and electrically connecting technique between front and back of Si die by filling with conductive metal. This technology allows that a three-dimensionally connected Si die can make without a large number of wire-bonding. These TSV technologies require various engineering skills such as forming a via hole, forming a functional thin film, filling a conductive metal, polishing a wafer, chip stacking and TSV reliability analysis. This paper addresses the TSV filling using Cu electrodeposition. The impact of plating conditions with additives and current density on electrodeposition will be considered. There are additives such as accelerator, inhibitor, leveler, etc. suitably controlling the amount of the additive is important. Also, in order to fill conductive material in whole TSV hole, current wave forms such as PR(pulse reverse), PPR(periodic pulse reverse) are used. This study about semiconductor packaging will be able to contribute to the commercialization of 3D TSV technology.

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.