• Title/Summary/Keyword: pulse forming

Search Result 110, Processing Time 0.03 seconds

A Study on the Multi Tapping Process Characteristics and Tread Quality under Difference Pitch (피치가 다른 다축 태핑에서의 가공 특성과 품질 평가에 관한 연구)

  • Lee, Jong-Hyung;Yi, Chang-Heon;Kim, Young-Moon;Lee, Sang-Young;Lee, Sang-Joong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.277-283
    • /
    • 2006
  • As the products such as HDD, Notebook, PDA, and Mobile Phone become smaller and thinner, the radius of threads as well as holes for assembling those products become smaller, even down to 1mm. To produce such small holes and thread efficiently, multi tapping is highly necessitated. However the multi tapping characteristics is not well known because its complicated cutting mechanism and thus the quality of the produced holes and threads is not well studied yet. In this paper, experiments have been conducted for small-radius threads using M2 and M2.6 and M3 cold forming tap to investigate multi tapping process using several useful signal such as torque and Z-axis encoder pulse. The surface and profile of the machined threads have been magnified and observed through a SEM.

  • PDF

Characteristics study of the spinning rotor gauges (점성진공계 특성연구)

  • 홍승수;신용현;임종연;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.293-297
    • /
    • 1997
  • Using trace etching method in this study, we measure the energy of argon ions generated in VEBA System which is composed of Marx Generater and Pulse Forming Line. In this system the electron beam of 240 kV, 30 kA, 60 ns is generated. Argon ions are formed through the electron beam ionization of a gas cloud injected by a fast puff valve. Thus argon ions are accelerated into vacuum drift tube by a virtual cathode and seperated with electron beam, consequently, they heat the trace etching plates made of aluminum thin films. The energy of argon ions are determined by the number of aluminum thin films penetrated by the ions. This experimental value corresponds with the theoretical value.

  • PDF

Development of the Crowbar System Using a Vacuum Switch (진공 스위치를 이용한 Crowbar 시스템의 개발)

  • 이태호;허창수;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

Application of 50-kV Inverter System for Testing a Characteristics of home-made 80-MW Pulsed Klystron (80 MW급 클라이스트론 성능시험을 위한 50 kV 인버터 시스템의 적용)

  • Jang S. D.;Son Y. G.;Oh J. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1172-1175
    • /
    • 2004
  • 포항 방사광 가속기의 선형가속기는 2.5GeV 전자빔용 마이크로웨이브의 발생을 위하여 80 MW급 클라이스트론(klystron) 11대와 입사부용 65 MW 급 클라이스트론 1대를 사용한다. 80 MW 급 클라이스트론 부하를 구동하기 위하여 최대 펄스 정격출력 200MW(400kV, 500A, 평탄도 $4.4\;{\mu}s$)인 대출력 펄스 전원공급 장치(modulator)가 요구된다. 모듈레이터 시스템 용 PFN(pulse forming network) 커패시터의 충전용 입력전원으로써 최대 출력전압 50 kV, ${\pm}\;0.5\%$ 이내의 전압제어가 가능한 고전압 인버터 전원장치를 적용하여 PLS 선형가속기용 국산화 개발 클라이스트론 부하의 성능시험을 수행하였다. 국산화 개발된 S-band 펄스 클라이스트론은 고전압 길들이기 과정을 거쳐 최대 정격 출력 빔 전압 400 kV 이상까지 시험 완료하였다. 클라이스트론의 정확한 RF 출력성능의 측정을 위하여 방향성 결합기와 검파기를 설치하여 측정시스템의 성능을 개선하였다. 본 논문에서는 포항 방사광 가속기의 국산화 개발 1호 클라이스트론 부하의 성능시험을 위한 50 kV 급 인버터시스템 적용과정에서 수행하였던 시험장치 개선과 PFN의 충전 특성을 분석하였다. 또한, 클라이스트론의 고전압 및 RF 길들이기 시험 결과에 관하여 고찰하고자 한다.

  • PDF

Performance Test of High-Power Pulsed Klystron-Load (대출력 펄스 클라이스트론 부하의 성능시험)

  • Jang, S.D.;Son, Y.G.;Oh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1756-1758
    • /
    • 2003
  • 포항 방사광 가속기의 선형가속기는 2.5GeV 전자빔 용 마이크로웨이브의 발생을 위하여 80MW 급 클라이스트론(klystron) 11대와 입사부 용 65MW 급 클라이스트론 1대를 사용한다. 80-MW 급 클라이스트론 부하를 구동하기 위하여 최대 펄스 정격출력 200 MW(400kv, 500A, 평탄도 4.4 ${\mu}s$)인 대출력 펄스 전원공급 장치(modulator)가 요구된다. 모듈레이터 시스템 용 PFN(pulse forming network) 커패시터의 충전용 입력전원으로써 최대 출력전압 50 kV, ${\pm}$ 0.5% 이내의 전압제어가 가능한 고전압 인버터 전원장치를 적용하여 클라이스트론 부하의 성능시험을 수행하였다. 클라이스트론의 RF 전력과 입력 빔의 특성을 정확히 측정하기 위하여 응답특성이 양호한 측정 장치와 정밀한 측정이 요구된다. 인버터 시스템의 적용에 따른 모듈레이터의 충전 특성을 파악하였으며, 방향성 결합기와 검파기를 설치하여 클라이스트론의 RF 출력을 측정하였다. 본 논문에서는 포항 방사광 가속기의 대출력 펄스 고주파원으로 사용되는 클라이스트론 부하의 성능시험 과정에서 수행하였던 시험장치 개선 및 특성 분석, 고전압(빔전압 320 kV) 및 RF 길들이기의 시험 결과에 관하여 고찰하고자 한다.

  • PDF

Design and Implementation of Magnetic Stimulation Device Suitable for Herpes Zoster and Post Herpetic Neuralgia

  • Tack, Han-Ho;Kim, Gye-Sook;Kim, Whi-Young
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.10 no.2
    • /
    • pp.199-214
    • /
    • 2020
  • An important technique of the present invention is primarily to parallel light detection, self-pulse therapy after diagnosis. Herpes zoster is a disease caused by varicella zoster virus, and the virus that has been latent in the dorsal root ganglion that controls the skin segment loses its immune system and physically damages it. It is an acute skin disease in which acute pain and bullous rash occur along the sensory ganglia, which are rehab by inducers such as malignant tumors. Dorsal root ganglion after complete recovery of varicella, relapsed after incubation in brain ganglion, latent virus sometimes suppressed activity by cell mediated immunity, and in cell ganglion with reduced cellular immunity. It proliferates and destroys neurons, causing pain while forming a rash and blisters. This can reduce cell necrosis and increase the phagocytosis and enzymatic activity through the movement of ions through the cell membrane, depolarization and membrane potential change, growth factor secretion, calcium ion transfer, chondrocyte synthesis, etc., And may offer treatment options for lesions of herpes zoster and post-herpetic neuralgia (PHN).Therefore, according to the present research, the diagnosis and treatment device of treating paing for herpes zoster and post-herpetic pain can be implemented in the early stage of herpes zoster, and conventional analgesic regulation, anti-inflammatory effect, post-herpetic neuralgia.

Acquisition and Verification of Dynamic Compression Properties for SHPB of Woven Type CFRP (Woven Type CFRP의 SHPB에 대한 동적 압축 물성 획득 및 검증)

  • Park, Ki-hwan;Kim, Yeon-bok;Kim, Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.363-372
    • /
    • 2020
  • Dynamic compressive material properties at high strain rates is essential for improving the reliability of finite element analysis in dynamic environments, such as high-speed collisions and high-speed forming. In general, the dynamic compressive material properties for high strain rates can be obtained through SHPB equipment. In this study, SHPB equipment was used to acquire the dynamic compressive material properties to cope with the collision analysis of Woven tpye CFRP material, which is being recently applied to unmanned aerial vehicles. It is also used as a pulse shaper to secure a constant strain rate for materials with elastic-brittle properties and to improve the reliability of experimental data. In the case of CFRP material, since the anisotropic material has different mechanical properties for each direction, experiments were carried out by fabricating thickness and in-plane specimens. As a result of the SHPB test, in-plane specimens had difficulty in securing data reproducibility and reliability due to fracture of the specimens before reaching a constant strain rate region, whereas in the thickness specimens, the stress consistency of the specimens was excellent. The data reliability is high and a constant strain rate range can be obtained. Through finite element analysis using LS-dyna, it was confirmed that the data measured from the pressure rod were excessively predicted by the deformation of the specimen and the pressure rod.

Modified Fold Type Helicone Reflector for Efficient Satellite TT&C Having Variable Coverage Area (가변 커버리지를 갖는 위성 관제용 접이식 헬리콘 반사체 안테나 성능 연구)

  • Lee, Sang-Min;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.914-923
    • /
    • 2009
  • Helix antennas have been widely applied to satellite TT&C, data communication and GPS receiver systems onboard military, remote sensing and communication purpose satellites. The helix antennas are known to be convenient to control impedance and radiation coverage characteristics with a maximum directivity in satellite z-axis. Waveguide horn is commonly used for radar system that needs ultra-wideband pulse for exploration ground radar and electromagnetic disability measurement etc. It has high efficiency and low reflection characteristics provided by the low-profile shape and suppressed radiation distortion. In this paper, a waveguide horn structure incorporated with helix antenna design is proposed for satellite applications that require ultra-wideband pulse radar and high rate RF data communication link to ground station over wide coverage area. The main design concern is to synthesize variable beam forming pattern based on modified horn-helix combination helicone structure such that multi-mission antenna is implemented applicable for TT&C, earth observation, high data rate transmission. Waveguide horn helps to reduce the overall antenna structure size by introduction fold type reflector connected to the tapered helix antenna. The next generation KOMPSAT satellite currently under development requires high-performance precision attitude control system. We present an initial design of a hybrid hern-helix antenna structure suitable for efficient RF communication module design of multi-purpose satellite systems.

Effects of exploration and molecular mechanism of CsV on eNOS and vascular endothelial functions

  • Zuo, Deyu;Jiang, Heng;Yi, Shixiong;Fu, Yang;Xie, Lei;Peng, Qifeng;Liu, Pei;Zhou, Jie;Li, Xunjia
    • Advances in nano research
    • /
    • v.12 no.5
    • /
    • pp.501-514
    • /
    • 2022
  • This study aimed to investigate the effects and potential mechanisms of Chikusetsusaponin V (CsV) on endothelial nitric oxide synthase (eNOS) and vascular endothelial cell functions. Different concentrations of CsV were added to animal models, bovine aorta endothelial cells (BAECs) and human umbilical vein endothelial cells (HUVECs) cultured in vitro. qPCR, Western blotting (WB), and B ultrasound were performed to explore the effects of CsV on mouse endothelial cell functions, vascular stiffness and cellular eNOS mRNA, protein expression and NO release. Bioinformatics analysis, network pharmacology, molecular docking and protein mass spectrometry analysis were conducted to jointly predict the upstream transcription factors of eNOS. Furthermore, pulldown and ChIP and dual luciferase assays were employed for subsequent verification. At the presence or absence of CsV stimulation, either overexpression or knockdown of purine rich element binding protein A (PURA) was conducted, and PCR assay was employed to detect PURA and eNOS mRNA expressions, Western blot was used to detect PURA and eNOS protein expressions, cell NO release and serum NO levels. Tube formation experiment was conducted to detect the tube forming capability of HUVECs cells. The animal vasodilation function test detected the vasodilation functions. Ultrasonic detection was performed to determine the mouse aortic arch pulse wave velocity to identify aortic stiffness. CsV stimulus on bovine aortic cells revealed that CsV could upregulate eNOS protein levels in vascular endothelial cells in a concentration and time dependent manner. The expression levels of eNOS mRNA and phosphorylation sites Ser1177, Ser633 and Thr495 increased significantly after CsV stimulation. Meanwhile, CsV could also enhance the tube forming capability of HUVECs cells. Following the mice were gavaged using CsV, the eNOS protein level of mouse aortic endothelial cells was upregulated in a concentration- and time-dependent manner, and serum NO release and vasodilation ability were simultaneously elevated whereas arterial stiffness was alleviated. The pulldown, ChIP and dual luciferase assays demonstrated that PURA could bind to the eNOS promoter and facilitate the transcription of eNOS. Under the conditions of presence or absence of CsV stimulation, overexpression or knockdown of PURA indicated that the effect of CsV on vascular endothelial function and eNOS was weakened following PURA gene silence, whereas overexpression of PURA gene could enhance the effect of CsV upregulating eNOS expression. CsV could promote NO release from endothelial cells by upregulating the expression of PURA/eNOS pathway, improve endothelial cell functions, enhance vasodilation capability, and alleviate vessel stiffness. The present study plays a role in offering a theoretical basis for the development and application of CsV in vascular function improvement, and it also provides a more comprehensive understanding of the pharmacodynamics of CsV.

THE HEALING EFFECTS OF LOW POWER DENSITY LASER TO THE EXPERIMENTAL PERIODONTITIS;HISTOPATHOLOGIC STUDY (저출력 레이저 조사가 성견의 실험적 치주질환 치유에 미치는 영향에 관한 조직병리학적 연구)

  • Kim, Dong-Woon;Lee, Jae-Hyun;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.16-26
    • /
    • 1993
  • In order to investigate the healing effect on inflammation and bone regeneration of low power density laser radiation in dogs, experimental periodontitis was made in dog mandibular 3rd, 4th premolars. All teeth were classified with four groups of two experimental group and control groups. The second group were irradiated on periodontitis site and the first group were control. The fourth group were irradiated on periodontitis site flap operation and the third group were flap control. Experimental groups were irradiated with GaAs low power density laser of pulse wave and continuous wave of 904nm every day by five days respectively and then control group and experimental groups were evaluated by histo-pathological study. The results were as follows : 1. Experimental periodontits site of dog were irradiated with GaAs low power laser results in reducing of pseudoepitheliomatous proliferation and inflammation at light microscope. 2. After irradiation with low power density laser, experimental groups were revealed that PDL forming activity were increased and newly formed collagen deposition were observed. 3. Low power density lsaer irradiation on experimental periodontits site after flap operation showed that decreasing of inflammation, reducing of osteoclast activity. Capillary proliferation, reduction of pseudoepitheliomatous proliferation. 4. After irradiation with low power density laser on flap experimental site, experimental groups were revealed that newly formed collagen in periodontal ligament and alveolar bone were detected on MT staining.

  • PDF