• Title/Summary/Keyword: pulse discharge

Search Result 665, Processing Time 0.026 seconds

The high repetition operating characteristics of pulsed Nd:YAG laser by parallel mesh and alternating charge-discharge system (병렬 메쉬 및 교번 충.방전 방식에 의한 펄스형 Nd:YAG 레이저의 고반복 동작특성에 관한 연구)

  • Park, K.R.;Kim, B.G.;Hong, J.H.;Kim, W.Y.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1060-1062
    • /
    • 1999
  • Pulsed Nd:YAG laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. And the parallel mesh is added to increase laser output power. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition, we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the parallel mesh and the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 10pps to 110pps by the step of 20pps at 1000V and 1200V, it is found that the laser efficiency decreases but the laser output power increases about 5W at each step.

  • PDF

The high repetition operating characteristics of pulsed Nd:YAG laser by alternating charge-discharge system (펄스형 Nd:YAG 레이저의 교번 충.방전 방식에 의한 고반복 동작특성)

  • Kim, W.Y.;Park, K.R.;Kim, B.G.;Hong, J.H.;Kang, U.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2204-2206
    • /
    • 1999
  • Pulsed Nd:YAC laser is used widely for materials processing and instrumentation. It is very important to control the laser energy density in materials processing by a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this study, the alternating charge-discharge system was designed to adjust a pulse repetition rate. This system is controlled by one chip microprocessor and allows to replace an expensive condenser for high frequency to a cheap condenser for low frequency. In addition. we have investigated the current pulse shape of flashlamp and the operating characteristics of a pulsed Nd:YAG laser. As a result, it is found that the laser output of the power supply using the alternating charge-discharge system is not less than that of typical power supply. As the pulse repetition rate rises from 30pps to 120pps by the step of 30pps at 1200V, it is found that the laser efficiency decreases but the laser output power increases about 6W at each step.

  • PDF

Numerical Simulation of the Characteristics of Electrons in Bar-plate DC Negative Corona Discharge Based on a Plasma Chemical Model

  • Liu, Kang-Lin;Liao, Rui-Jin;Zhao, Xue-Tong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1804-1814
    • /
    • 2015
  • In order to explore the characteristics of electrons in DC negative corona discharge, an improved plasma chemical model is presented for the simulation of bar-plate DC corona discharge in dry air. The model is based on plasma hydrodynamics and chemical models in which 12 species are considered. In addition, the photoionization and secondary electron emission effect are also incorporated within the model as well. Based on this model, electron mean energy distribution (EMED), electron density distribution (EDD), generation and dissipation rates of electron at 6 typical time points during a pulse are discussed emphatically. The obtained results show that, the maximum of electron mean energy (EME) appears in field ionization layer which moves towards the anode as time progresses, and its value decreases gradually. Within a pulse process, the electron density (ED) in cathode sheath almost keeps 0, and the maximum of ED appears in the outer layer of the cathode sheath. Among all reactions, R1 and R2 are regarded as the main process of electron proliferation, and R22 plays a dominant role in the dissipation process of electron. The obtained results will provide valuable insights to the physical mechanism of negative corona discharge in air.

The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics (AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석)

  • Lee, Young-Jun;Choi, Su-Sam;Park, Se-Kwang;Kim, Yong-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

A Study on the Development and Characteristics Evaluation of Non-Contact HFCT Sensor for Partial Discharge Measurement (부분방전 측정용 비접촉식 HFCT 센서개발 및 특성평가에 관한 연구)

  • Sang-Bo Han
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.131-135
    • /
    • 2024
  • In this study, the sensor such as current transformer type was developed for measuring non-contact partial discharge in power electrical facilities, and the results of the characteristic evaluation were discussed. The frequency response characteristics of the HFCT sensor were shown to be measurable from 20 [kHz] to 20 [MHz]. The average sensitivity for the positive direction was 0.308 [mV/pC], and the negative direction was 0.459 [mV/pC]. Which showed that the sensitivity for the negative direction was better than that for the positive direction. The developed HFCT sensor is possible to measure very small partial discharge pulse signals and can be measured various types of partial discharge that may occur at power electrical facilities.

Study on the Reduction of Energy Consumption in the Pulsed Corona Discharge Process for NOx Removal (질소산화물 제거를 위한 펄스코로나 방전공정의 에너지 소모 저감에 관한 연구)

  • 정재우;손병학;조무현;목영선;남궁원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.475-483
    • /
    • 1999
  • A lab-scale test was carried out to study the reduction of electrical energy consumption in the pulsed corona discharge process for nitrogen oxides removal. The experiment was mainly focused on 1) the activation of pollution removal reactions by chemical additives and 2) the optimization of electrical circuit for the efficient energy transfer from the power supply to the corona reactor. Hydrocarbon chemical additives used in the experiment are thought to be responsible for the enhancement of the NO conversion through the chain reactions of free radicals such as, R, RCO, and RO. Electrical energy consumption per converted NO molecule has a minimum value of 17 eV when pentanol is injected. When ethylene and propylene are injected, 30 eV and 22 eV of electrical energy consumption is required for the conversion of NO molecule respectively. The ratio of the pulse forming capacitance$(C_e)$ to the reactor capacitance$(C_R)$ plays an important role in the energy transfer efficiency to the reactor. Maximum energy transfer efficiency of approximately 72% could be obtained by using the pulse forming capacitance which is 3.4 times larger than the reactor capacitance, and also the maximum NO conversion efficiency was observed with the same condition.

  • PDF

Performance Evaluation of 2-Dimensional Light Source using Mercury-free Flat Fluorescent Lamps for LCD Backlight Applications

  • Park, Joung-Hu;Cho, Bo-Hyung;Lee, Ju-Kwang;Whang, Ki-Woong
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.164-172
    • /
    • 2009
  • Recently, 2-dimensional flat light sources have been attracting much attention for its use in LCD backlight applications because of its high luminous efficiency and uniformity. A long-gap discharge, mercury-tree flat fluorescent lamp has been developed, which shows a high brightness ($>5000\;cd/m^2$) and high luminous efficacy (60 lm/W). Additionally, it has a wide operating margin and stable driving condition with the aid of an auxiliary electrode. For driving the lamp, a narrow pulse power to maintain the glow discharge state is required. Since there has been no research for this kind of lamp driving, this paper proposes a newly developed short-pulse, high-voltage lamp-driving scheme. The proposed lamp system uses a ballast with a coupled-inductor in order to raise the short pulse voltage up to the lamp ignition level and to obtain energy-recovery action during the glow discharge mode. The operation principles are presented and also the system performances such as the lighting efficiency, spatial and angular uniformities are evaluated by hardware experiments. The results show that the proposed lighting system is a good candidate for the next-generation of LCD backlight systems.

Corona Discharge Phenomena on the Dielectric Electrodes in High Field (고전계하에서 유전체 전극에 나타나는 코로나 현상)

  • Kim, Jung-Dal;Lee, Duck-Jin;Joo, Sung-Cheol;Jung, Jang-Gun;Chang, Gi-Hyuk;Lee, Sae-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF