• 제목/요약/키워드: pulse diagnosis on radial artery

검색결과 26건 처리시간 0.027초

공압 방식에 의한 다지점 요골 맥파 검출 장치 (Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System)

  • 이종진;정민석;황성하;이종현;이선규
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 - (Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis -)

  • 김경철;이정원;류경호;박동일;신우진;강희정
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

한의사의 진단, 설문지, 맥진을 이용한 미병 관리에 관한 관찰적 임상연구 (Observational Clinical Study on Mibyeong Based on Korean Medicine Diagnosis, Questionnaire, and Radial Artery Tonometry)

  • 문희영;김민수;임수현;채윤병;이인선
    • Korean Journal of Acupuncture
    • /
    • 제40권2호
    • /
    • pp.44-53
    • /
    • 2023
  • Objectives : This study was conducted to reveal the relationship between multiple factors of traditional Korean Medicine diagnosis and consider the further probabilities of treating people with physical and mental problems not defined as diseases, which is called 'Mibyeong' in traditional Korean Medicine. Methods : 40 healthy participants were included in the observational clinical trial. The participants were asked to complete health questionnaires (e.g. State-Trait Anxiety Inventory, Pittsburgh Sleep Quality Index, Stress Response Inventory) and they went through a traditional diagnosis process, including four stages of diagnosis (looking, listening/smelling, inquiring, and pulse taking), by a Korean Medicine doctor. Both the Korean Medicine doctor and an artery tonometry device performed the pulse diagnosis. Results : Although all participants were healthy people with no history of disease, more than half of participants had a problem related with severe level of fatigue (n=19), sleep disturbance (n=26) and stress (n=27) status according to the related questionnaires. Participants diagnosed with phlegm syndrome by the Korean Medicine doctor showed significantly greater score in phlegm pattern questionnaires than participants who were not. However, there was little agreement between the doctor's pulse diagnosis and radial artery tonometry results. Conclusions : We conducted a pulse diagnosis and measured health-related information along with the traditional Korean Medicine diagnose procedure, including four stages of diagnosis, and we found a linkage between diagnosis of phlegm and the phlegm pattern questionnaire score. The results suggest that a number of healthy participants, with no disease diagnosed, have Mibyoung symptoms which need further clinical management. Thus, we suggest that Mibyoung management programs based on qualified diagnosis tools and traditional Korean medicine diagnosis procedures be developed, and that future research using various diagnostic tools be carried out on a large population.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

"황제내경"에 나타난 침자 전후의 맥진 (Pulse diagnosis procedure before and after the acupuncture in Hwangjenaekyung)

  • 배성철;신승훈;김기왕
    • 대한한의학원전학회지
    • /
    • 제24권3호
    • /
    • pp.15-25
    • /
    • 2011
  • The acupuncture procedures in Hwangjenaekyung (黃帝內經) was different to modern ones in many aspects. Especially, the role of pulse diagnosis in acupuncture was totally different and the pulse diagnosis was essential part in acupuncture therapy in Hwangjenaekyung era. We found four noteworthy features on the pulse diagnosis before and after acupuncture in Hwangjenaekyung : (1) Pulse diagnosis was a mandatory process in acupuncture (2) Doctors who used pulse diagnosis in 12 meridians (十二經脈遍診脈法), pulse diagnosis in 9 points of 3 body parts (三部九候脈法), and comparative pulse diagnosis between radial artery and carotid artery (人迎寸口對比脈法) followed the former rule ((1)). (3) The major pulse features to detect before and after acupuncture were conversion between the vacuous pulse (虛脈) and the replete pulse (實脈), and conversion between slippery pulse (滑脈) and rough pulse (澁脈). (4) Deukki (得氣, Deqi) was synonym of Kiji (氣至), and it referred to the changes of arterial pulse, not the sensation followed by acupuncture manipulation.

BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구 (The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI)

  • 이유정;이전;이혜정;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF

토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화 (AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry)

  • 조정희;전영주;전민호;김영민
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ) (A Study on the Radial Pulse Detection System for the Total Macjin( I ))

  • 김규상;양승렬;한순천;박영배;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구 (A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women)

  • 이인선;전수형;강창완;김종원
    • 동의생리병리학회지
    • /
    • 제35권6호
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.