• Title/Summary/Keyword: pulse count

Search Result 87, Processing Time 0.031 seconds

Discrimination of insulation defects using a neural network (신경회로망을 이용한 절연 결함의 판별)

  • 최재관;김재환;김성홍;윤헌주;박재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.381-384
    • /
    • 1997
  • This paper describes the method of diagnosing the degradation by void defects of insulator inside in operation. Needle-shape void specimens, made from LDPE, were used to generate an electrical tree under ac voltage. The method uses a neural network system with input signal of AE patterns. AE pattern consists of the pulse count and average amplitude according to the phase angle. After the learning process was over, unknown emission patterns were put into the network. It was shown that the network discriminates the void deflects well. The effectiveness of the neural network system for partial discharge recognition was shown.

  • PDF

Hydrologic Regime Alteration Analysis of the Multi-Purpose Dam by Indicators of Hydrologic Alterations (수문변화 지표법에 의한 다목적댐의 유량변화 분석)

  • Park, Bong-Jin;Kang, Ki-Ho;Jung, Kwan-Sue
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.7
    • /
    • pp.711-723
    • /
    • 2008
  • In this study, Hydrologic regime alterations(magnitude, magnitude and duration of annual extreme, frequency and duration of high and low pulse, rate and frequency of water condition changes, Range of Variability Approach) were analyzed by using Indicators of Hydrologic Alterations at the 11 major multi-purpose dam. The analysis result of the magnitude of monthly water conditions during drought season, inflow was $6.38m^3/sec{\sim}39.84m^3/sec$ and outflow was $20.36m^3/sec{\sim}49.43m^3/sec$, was increased $1.84%{\sim}200.98%$. The analysis result of the magnitude of monthly water conditions during flood season, inflow was from $79.06m^3/sec{\sim}137.12m^3/sec$ and outflow was from $65.32m^3/sec{\sim}80.16m^3/sec$, was decreased from $18.19%{\sim}40.39%$. The analysis result of the magnitude and duration of annual extreme, 1-day minimum was increased $82.86%{\sim}2,950%$, but 1-day maximum was decreased $34.78%{\sim}83.96%$. The analysis result of the frequency and duration of high and low pulse, low pulse count was decreased $29.67%{\sim}99.07%$ and high pulse count was also decreased $4.6%{\sim}92.35%$ after dam operation. Hydrograph rise rate was decreased $15.84%{\sim}79.31%$ and fall rate was $1.97%{\sim}107.10%$. RVA of 1-day minimum was increased $0.60{\sim}2.67$, also RVA of 1-day maximum was decreased $0.50{\sim}1.00$.

A Study on the Skin Characteristics of Qi Deficiency and Blood Deficiency Animal Model (기허(氣虛), 혈허(血虛) 동물모형(動物模型)의 일반(一般) 특성(特性) 및 피부(皮膚) 특성(特性) 연구(硏究))

  • Shin, Yoon-Jin;Kim, Yoon-Bum
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.22 no.1
    • /
    • pp.76-88
    • /
    • 2009
  • Back ground and Objective : There is a need for objectification and scientific verification of Pattern identification in Oriental medicine. The purpose of this study was to investigate the skin characteristics of Qi deficiency and Blood deficiency animal models. Material and Methods : Sprague-Dawley rats were divided into three groups: normal group, Qi deficiency group and Blood deficiency group. The Qi deficiency animal model was induced through restriction of food (75g/kg/day) for 20 days. Blood deficiency animal model was induced by bleeding from tail vein(0.3 ml/time) 8 times. The normal animal model was kept without any intervention. The general condition was observed by measuring body weight, body temperature, blood pressure, pulse rate, and hematological and biochemical parameters. The skin characteristics were observed by measuring the erythema index(EI), melanin index(Ml), transepidermal water loss(TEWL) and dermal microcirculation. Results : 1. In the Qi deficiency group, body weight was lower than the other groups. In the Qi deficiency group, blood pressure was lower than in the Normal group. There was no difference in body temperature and pulse rate between the three groups. 2. In the Qi deficiency group, blood sugar was lower than in the Blood deficiency group. There was no difference in triacylglycerol between the three groups. In the Qi deficiency group, the WBC count was lower than in the Blood deficiency group. RBC count was highest in the Qi deficiency group, Normal group and Blood deficiency group respectively. In the Qi deficiency group, Hb and Hct were higher than the other groups. 3. EI and MI were decreased in the Qi deficiency group, and EI showed a significant decrease. 4. EI and MI were increased in the Blood deficiency group, and MI showed a significant increase. 5. TEWL was significantly increased in the Qi deficiency group, while it was decreased in the Blood deficiency group, TEWL was highest in the Qi deficiency group, Normal group and Blood deficiency group respectively and all three groups showed significant difference. 6. In the Qi deficiency group, dermal microcirculation was lower than the other groups. Conclusion : The above results show that the erythema index decreases in the Qi deficiency model, and the melanin index increases in the Blood deficiency model. The Qi deficiency animal model shows an increase in transepidermal water loss, while the Blood deficiency animal model shows a decrease. Further studies should develop new models of Pattern Identification that are more specific.

  • PDF

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.

Partial Discharge Characteristics of Metallic Particles Under HVDC in SF6 Gas (SF6 가스 중 HVDC에서 금속 파티클의 부분방전 특성)

  • Kim, Sun-Jae;Jo, Hyang-Eun;Wang, Guoming;Yun, Min-Young;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.831-836
    • /
    • 2015
  • This paper dealt with the PD (partial discharge) characteristics produced by metallic particles presented in a gas insulated switchgear. Four types of metallic particles such as a ball, a trapezoid, a rectangle, and a twist were fabricated and placed in a PD cell filled with $SF_6$ gas. PD pulses were detected through a $50{\Omega}$ non-inductive resistor. Calibration was carried out according to IEC 60270 and the sensitivity was calculated as 4 mV/pC. Apparent charge, pulse count, DIV (discharge inception voltage), DEV (discharge extinction voltage), and TRPD (time resolved partial discharge) were analyzed. Among the metallic particle types, the twist frequently occurred PD pulse at the lowest DIV, while the rectangle showed the highest. DEV of the twist was about 2 times lower than that for the rectangle. Kurtosis of ball clustered at high value, and skewness of other three metallic particles distributed at low value. TRPD showed different distribution by metallic particle types.

Physical Feature, Physiological Character and Behavior Study of Gayal(Bos frontalis)

  • Giasuddin, M.;Islam, M.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.11
    • /
    • pp.1599-1603
    • /
    • 2003
  • The physical feature, physiological character and behavior studies were conducted with fifteen newly collected gayals in Bandarban hill tract area of Bangladesh. Their morphology is different from domestic cattle. The range of pulse rate, body temperature and respiration rate were 47 to 75 per minute, 37.78 to $38.88^{\circ}C$ and 20 to 40 per minute, respectively. These physiological values vary with different age group and seasonal variation. In hematological feature, the average findings were RBC $7.01{\pm}0.52$ million/cu.mm, WBC $14.3{\pm}3.69$ thousand/cu.mm, hemoglobin concentration $9.81{\pm}2.25gm%$, PCV $35.86{\pm}3.68%$. In differential WBC count neutrophils $28.23{\pm}1.75%$, lymphocytes $62{\pm}2.05%$, monocytes $4.4{\pm}1.34%$, eosinophils $5{\pm}2.49%$ and basophils $0.4{\pm}0.51%$. In behavior study, the animal shows browsing nature on hill slopes. They are watchful in new environment, become excited and nervous with strangers. Heated female gayals response for mating with domestic bull.

Wide-bandwidth SQUID Current Amplifier and Control Electronics for X-ray Microcalorimeter (X-선 미소열량계 신호 검출을 위한 광대역 SQUID 전류증폭기와 조절 회로)

  • 김진목;이용호;권혁찬;김기웅;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.31-37
    • /
    • 2003
  • Wide-bandwidth SQUID current amplifier and its control electronics have been constructed for detecting pulse outputs of a superconducting microcalorimeter. The current amplifier made of a double relaxation oscillation SQUID (DROS) has a bandwidth of 1.2 MHz and typical white noise level of about 6 pA/(equation omitted) Hz. To increase the dynamic range of the current amplifier, the flux-locked loop (FLL) has additional circuits to reset the integrator and to count reset numbers which present the number of passed flux quanta. In this system, dynamic range covers from -65 mA to +65 mA. SQUID electronics are controlled by software to get the optimum FLL condition, and to control the current to bias the transition edge sensor (TES). The electronics are shielded from the outside electromagnetic noises by using an aluminum case of 66 mm ${\times}$ 25 mm ${\times}$ 100 mm, and consist of 2 separate printed-circuit-boards for the current amplifier and the control electronics, respectively. The SQUID current amplifier and its control electronics will be used in TESs for detecting photons such as UV and X-ray with high energy resolution.

  • PDF

New High Performance and Low Cost Construction of Unified Power System For LCD TV Backlight Driver Circuit (LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템)

  • Jang, Doo-Hee;Lee, Jae-Kwang;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jin-Wook;Lee, Hyo-Bum;Han, Sang-Kyoo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.244-246
    • /
    • 2008
  • 본 논문에서는 LCD TV의 인치에 따라 다르게 적용되는 기존의 전원 구동 분리형 시스템과 전원 구동 IP 시스템을 검토하여, 두 시스템의 장점만을 모아 LCD TV 전원 시스템의 표준화가 가능한 새로운 방식의 구동 전원 통합 시스템을 제안한다. 제안 시스템은 가격 및 효율이 우수한 2단 구성으로 이루어져 있고, 안전규격을 만족하기 위하여 EMI측면에 유리한 1:1 Trans.를 사용하였다. 인버터 부의 최적 동작을 위해 인버터 구동신호의 주파수와 시비율을 고정하고 펄스 개수를 제어하는 Pulse Count Modulation(PCM)방식을 채용 하였다. 제안 시스템의 인버터단은 전 부하 범위에서 영전압 스위칭이 가능하여 스위치의 발열이 우수하고, 별도의 전류 평형 Trans.가 필요치 않으므로 Balance Coil의 삭제가 가능하다. 이로 인해 신뢰성이 높은 제품 구성이 가능하고, PCB Size 축소 및 제품 제작 단가가 낮아지는 장점을 갖는다. 최종적으로 제안 시스템을 기존 시스템과 비교 및 실험적 검증을 통하여 제안 시스템의 그 우수성을 확인한다.

  • PDF

Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator (광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility (전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석)

  • Pang, Man-Sik;Choi, Jae-Hyeong;Kim, Woo-Jin;Kim, Young-Seok;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.4
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.