Correlation Analysis Between DeNOx and $DeSO_2$ and Specific Energy Density in Pulse Corona Discharge (펄스 코로나 방건공정내에서의 비에너지 밀도에 따른 탈황.탈질 특성의 상관성 분석)

  • 정재우;이용환;최유리;조무현;남궁원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.235-236
    • /
    • 2000
  • 배기가스의 처리를 위한 펄스 코로나 방전공정은 질소 산화물 및 황산화물을 동시에 제거할수 있는 효율적인 공정으로 알려져 있으며 현재 국내외에서 많은 연구들이 수행되고 있는 공정이다. 플라즈마 상태를 이용하는 펄스 코로나 방전공정에서 운전변수들의 변화는 플라즈마 특성을 변화시켜 공정의 효율성에 영향을 미치게 된다. 특히 플라즈마의 특성에 영향을 미치는 여러 가지 변수들 사이에는 강한 상호의존성을 갖고 있으므로 하나의 운전변수가 미치는 영향에 관한 정확한 규명은 매우 복잡하고 어려운 일이다. (중략)

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings (6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계)

  • Lim, Kwang-Jin;Lwin, Kyaw-Soe;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

The Design of a Planar Patch Sensor for Partial Discharge Diagnosis in 6.6 kV Rotating Machine Stator Windings (6.6 kV 회전기 고정자 권선에서 부분방전 신호 검출을 위한 평면 패치 센서 설계)

  • Lim, Kwang-Jin;Park, Noh-Joon;Kim, Hee-Dong;Ju, Young-Ho;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.481-485
    • /
    • 2008
  • In stator windings of 6.6 kV rotating machine, corona discharge, surface discharge and internal discharge are caused mainly by internal voids and insulation degradation. Also, if partial discharge occurs in inner-part of stator windings, it will be happened electromagnetic pulses at wide frequency range. In case of discharge spark, electromagnetic pulse generated from discharge source, and we can detect it by using various RF resonators as an EM sensor. In order to detect these kind of electromagnetic sources, we have designed and fabricated planar patch sensor using CST MWS simulation, and also PD signals from artificial defected cable were measured by our proposed sensor. Furthermore, HFCT was used as a reference sensor and compared with our proposed new planar patch sensor.

PD Diagnosis On High Voltage Rotating Machines using UWB Sensor (UWB 센서 설계를 통한 고압회전기의 부분방전 진단 연구)

  • Lwin, Kyawsoe;Lim, Kwang-Jin;Shin, Dong-Hoon;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.197-198
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic pulse emitted from the partial discharge source in the stator winding of HV Rotating Machine with UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on micro-strip technology and made experiments of offline dismantled testing compare with the traditional HFCT as a reference sensor in the laboratory. We investigated internal discharge, surface discharge, corona discharge and non-defected state normal stator on pre-made stator winding by using UWB patch sensor.

  • PDF

Tracking Propagation Mechanism on the Surface of Polyvinyl-Chloride-Sheathed Flat Cord based on Electric Field Analysis and Gas Discharge Physics (전계해석과 기체방전 이론을 기반으로 한 Polyvinyl-Chloride-Sheathed Flat Cord 표면의 트래킹 진전 메커니즘)

  • Lim, Dong-Young;Park, Herie;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.30-38
    • /
    • 2019
  • Tracking, which is one of the main causes of electrical fires, is perceived as a physical phenomenon of electrical discharge. Hence tracking should be explained based on electric field analysis, conduction path by electron generation, and gas discharge physics. However, few papers have considered these details. This paper proposes a tracking mechanism including their effects on tracking progress. In order to prove this mechanism, a tracking experiment, an electric field analysis for the carbonization evolution model, and an explanation of the tracking process by gas discharge physics were conducted. From the tracking experiment, the current waveforms were measured at each stage of the tracking progress from corona discharge to tracking breakdown. The electric field analysis was carried out in order to determine the electric field on the surface of a dry-band and the high electric field region for electron generation during the generation and progress of carbonization. In this paper, the proposed tracking mechanism consisted of six stages including electron avalanche by corona discharge, accumulation of positive ions, expansion of electron avalanche, secondary electron emission avalanche, streamer, and tracking by conductive path. The pulse current waveforms measured in the tracking experiment can be explained by the proposed tracking mechanism. The results of this study will be used as the technical data to detect tracking phenomenon, which is the cause of electric fire, and to improve the proof tracking index.

Spectroscopic Study of the X-ray Dip at Pre-eclipse Phase of Hercules X-1

  • Choi, C.S.;Nagase, F.;Makino, F.;Dotani, T.;Min, K.W.
    • Bulletin of the Korean Space Science Society
    • /
    • 1992.10a
    • /
    • pp.21-21
    • /
    • 1992
  • The X-ray binary pulsar Her X-1 was observed with Ginga on 1988 August 28 during the orbital phase of 0.76 to 0.85 at the main-on phase of the 35 day cycle. During the observations the X-ray intensity varied by a factor of five or more on a time scale as short as 30 sec, due mostly to the soft X-ray absorption in the pre-eclipse phase. From the studies of pulse profiles and energy spectra, we revealed that there exists in the dipphase an unpulsed component which is "3% of the intensity at the non-absorbed high-level. We suggest that scattering of the source continuum by the optically thin hot corona is responsible for the unpoised component. In the spectral analysis, we find that the high-state non-absorbed spectra can be fitted by a power-law without absorption, and the spectra observed in the different abgorption states by two components of a power-law with the same photon index. An iron-K emission line is required in to the cases of fitting. The estimated equivalent width of the iron line varies from 0.18 to 0.51 key according to the change in the absorption column density along the line of sight. We suggest that the fluorescent iron line arises in a cool and relatively small region, like the Alfvensur face, and may be partially intercepted by the optically thick gas cloud passing across the line of sight.1 Korea Astronomy Observatorya The Institute of Space and Astronautical Science in Japan3 Korea Advanced Institute of Science and Technology

  • PDF

Epidemic acute interstitial pneumonia in children occurred during the early 2006s (2006년 초에 유행한 소아 급성 간질성폐렴)

  • Cheon, Chong Kun;Jin, Hyun-Seung;Kang, Eun Kyeong;Kim, Hyo Bin;Kim, Byoung-Joo;Yu, Jinho;Park, Seong Jong;Hong, Soo-Jong;Park, June Dong
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.383-390
    • /
    • 2008
  • Purpose : This study was aimed to analyze the clinical characteristics of patients with acute interstitial pneumonia who had presented similar clinical patterns from March to June, 2006 and to describe our experience of treatment and to identify risk factors associated with prognosis. Methods : The clinical characteristics, radiologic and histopathologic findings and response to steroids of 15 patients (non-survival group [n=7] and survival group [control, n=8]) with acute interstitial pneumonia were investigated through the review of medical records. Results : The mean age of the patients was 26 (range: 3-48) months. Cough, cyanosis and fever were frequent symptoms. The most frequent radiologic findings on admission were pneumomediastium and extensive ground glass opacity. Surgical lung biopsy was performed on 8/15 (53.3%) patients and diffuse alveolar damage was found. Mechanical ventilation was applied for 9/15 (60.0%) patients for 40 (range: 1-99) days. Five patients in survival group received steroid treatment and 7 patients in non-survivial group (P=0.20). One patient in survival group received steroid pulse treatment and 4 patients in non-survival group (P=0.12). Seven patients died all of respiratory failure. The survival rate was 53.4%. Conclusion : The patients with acute interstitial pneumonia which occurred on spring 2006 showed high mortality because of rapidly and extensively progressing pulmonary fibrosis and air leakage. Therefore, we should consider surgical lung biopsy and steroid application earlier. We should recognize this acute interstitial pneumonia occurring on spring in domestics and need to investigate the cause and treatment in large scale.