• Title/Summary/Keyword: pulse conditions

Search Result 757, Processing Time 0.028 seconds

Comparative Studies on the Concordance Rate of Pulse Condition Interpretation between Interpreters and Pulse Analyser (맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구)

  • Kang, Sei-Young;Jang, In-Soo;Kim, Lak-Hyung
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.91-99
    • /
    • 2011
  • Objectives : The purpose of our investigation is to determine degrees of concordance rate among interpreters. Furthermore, we have examined how much concordance rate to come out when beginners have been compared with the pulse analyzer. Methods : Thirty-nine volunteers were enrolled for this study. These subjects took a 5-minute rest in a sitting position as instructed by the protocol. As they were not allowed to move or speak, radial artery pulse conditions were measured on the lower arm of each subject by means of the pulse analyzer under investigation. Two Korean medical doctors, who did not know the status of default pulse conditions, were also instructed to intuitively choose the most corresponding one in comparison with 13 default pulse conditions. Subsequently, we investigated results between interpreters as well as results between interpreter and pulse analyzer. Results : The total concordance rate, with similar concordance rates being included, between interpreters, between interpreter A and pulse analyzer, and between interpreter B and pulse analyzer was 56.4%, 79.5%, and 71.8% respectively. In faint fine weak pulse(微細弱脈) case, interpreter A and B selected 6 and 7 cases respectively, matched the concordance rate 5, and corresponded separately with the pulse analyzer interpreting 8 cases. Conclusions : In case of skipping pulse 2(促2脈), short pulse(短脈), faint fine weak pulse(微細弱脈), the concordance between interpreters also matches with results drawn from the pulse analyzer. The concordance rate goes higher in proportion with such smaller pulse conditions as faint fine weak pulse(微細弱脈) and short pulse(短脈).

Influence of extreme curing conditions on compressive strength and pulse velocity of lightweight pumice concrete

  • Anwar Hossain, Khandaker M.
    • Computers and Concrete
    • /
    • v.6 no.6
    • /
    • pp.437-450
    • /
    • 2009
  • The effect of six different curing conditions on compressive strength and ultrasonic pulse velocity (UPV) of volcanic pumice concrete (VPC) and normal concrete (NC) has been studied. The curing conditions include water, air, low temperature ($4^{\circ}C$) and different elevated temperatures of up to $110^{\circ}C$. The curing age varies from 3 days to 91 days. The development in the pulse velocity and the compressive strength is found to be higher in full water curing than the other curing conditions. The reduction of pulse velocity and compressive strength is more in high temperature curing conditions and also more in VPC compared to NC. Curing conditions affect the relationship between pulse velocity and compressive strength of both VPC and NC.

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler (동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

A Study on Pulse Condition of Sameumsamyang(三陰三陽) in "Hwangjenaegyeong(黃帝內經)" ("황제내경(黃帝內經)"의 삼음삼양(三陰三陽) 맥상(脈象)에 대한 소고(小考))

  • Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.21 no.3
    • /
    • pp.119-125
    • /
    • 2008
  • Among the various pulse diagnosis contents in "Hwangjenaegyeong(黃帝內經)", we researched the pulse conditions that are belonged to Sameumsamyang(三陰三陽), and made a comparative study with pulse conditions of five organs[五臟], that of six meridians in "Sanghallon(傷寒論)". So from now on, this study would make help to understand standard pulse condition of Sameumsamyang(三陰三陽) diseases for clinical application. In "Hwangjenaegyeong(黃帝內經)", pulse condition of Taeyang(太陽) is expressed to be floating, Yangmyeong(陽明)'s condition to be strong but with a little bit weakness, Soyang(少陽)'s condition to be intermediate between Eum(陰) and Yang(陽), Taeeum(太陰)'s condition to be low and soft, So-eum(少陰)'s condition to be low and weak with some occasional upward tendency, Gweoleum(厥陰)'s condition to be mixed state of Eum and Yang.

  • PDF

The Effect of Pulse Plating on the Current Efficiency in Trivalent Chromium Bath (3가크롬 도금욕에서 펄스도금조건이 전류효율에 미치는 영향)

  • 황경진;안종관;이만승;오영주
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.2
    • /
    • pp.161-167
    • /
    • 2003
  • In order to investigate the effects of pulse plating conditions on the electrodeposition of trivalent chromium, electroplating experiments from bath with low concentration of trivalent chromium were performed. The variation of current efficiency of chromium electroplating with the electroplating conditions was explained. The maximum current efficiency of pulse plating is 6.4 times as high as that of direct plating at the same mean current density The nodular size increased with pulse plating time and the pulse frequency.

Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system (사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Kim, Tae Hyeung;Li, Xiao Yu;Ha, Hyun Chul;Jung, Jae Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

The Relationship between Welding Conditions and Ultrasonic Reflection Coefficients of Dissimilar Metals Friction Welded Joints (이종재 막찰용접 이음부에서의 초음파 반사계수와 용접조건과의 관계)

  • 오세규;김동조;한상덕
    • Journal of Ocean Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.138-143
    • /
    • 1987
  • Friction welding has emerged as a reliable process for high-production commercial applications with significant economic and technical advantages. But nondestructive test in friction weld was not clearly developed. Therefore the experimental verification is necessary in order to understand the characteristcs of the pulse echo effects according to various change in welding conditions. This paper presents an attempt to determine the relationship between the varios welding conditions and the coefficients of reflection using the ultrasonic pulse echo method in dissibilar metals friction weld. The new approach of calculating the coefficients of reflection based on measured amplitudes of the echoes is applied in this paper. These coefficients provides a single quantitative measurement which involves both acoustic energy reflected at the welded interface as well as transmitted across the interface. As a result, it was known that the quantitave relationship between welding conditions and the coefficients of reflection using the ultrasonic pulse echo exists in dissimilar metals friction weld.

  • PDF

Delphi Study for Developing Consensus of Physical Attribute in Pressure Pulse Waveform (맥상파 물리량 속성 총의형성을 위한 델파이 연구)

  • Lee, Haebeom;Kim, Hyunho;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.18 no.3
    • /
    • pp.137-148
    • /
    • 2014
  • Objectives This study was conducted to derive consensus about physical attributes in pressure pulse waveform and pulse conditions by Delphi study. Methods Delphi research was conducted for 2 rounds via e-mail. 8 Professors who lecture on a diagnostics of K. M. from the society of Korean medicine diagnostics were participated in this survey. They were asked for answering about series of definition for a physical attribute in pressure pulse waveform and combination for physical attributes of pulse conditions. Results 4 survey items were decided to have high validity and 9 survey items were decided to come to consensus about a physical attribute in pressure pulse waveform. 6 pulse condition were decided to come to consensus. Conclusion Using Delphi method, physical attributes in pressure pulse waveform and combinations of physical attribute in pulse condition come to consensus.