• 제목/요약/키워드: pulse cleaning

검색결과 52건 처리시간 0.027초

카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구 (Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System)

  • 박승욱;하현철;김성준
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

파장이 다른 레이저의 임플란트 세정 효과에 관한 연구 (Study on Implant Cleaning Effect of Lasers of Different Wavelengths)

  • 박은경;양윤석;이가람;유영태
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.643-651
    • /
    • 2013
  • This study applied a laser cleaning method (dry cleaning) that is used for cleaning semiconductor elements to dental implant cleaning. The lasers used in this study were pulsed fiber lasers with wavelengths of 1,064 and 532 nm. The peak output, energy per pulse, energy density per pulse, time of pulse experiment, and number of pulse experiments served as process variables for this study, and the variables were changed for each experiment. As a result, a laser with a wavelength of 532 nm showed much higher cleaning efficiency than its 1,064 nm counterpart. As the wavelength range decreased, the quantized energy increased and the reflection rate of the titanium used for the implant decreased; consequently, the energy absorption rate increased. Therefore, it is proposed that the energy density by wavelength has a greater influence on cleaning than does the output size.

세라믹필터 역세정을 위한 노즐 사이즈 최적화 (The optimization of nozzle size for pulse cleaning of ceramic filter)

  • 최주홍;김진형;지화창;우량;사공경민;김영애
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.796-799
    • /
    • 2007
  • In the bench scale test unit consisting of four commercial filter elements, the traces of the transient pressure around the nozzle and overpressure in the filter cavity were measured to estimate the effect of nozzle on pulse cleaning. For the given pulse cleaning system, the convergent nozzle displayed better performance than the straight one. The optimum ratio of outlet to inside diameter of convergent nozzle was determined, which minimized the pulse gas consumption and maximized the entrainment effect. The angle and height of nozzle convergent part was also optimum operational condition, which is meaningful to the industrial applying.

  • PDF

사각형 여과집진기 충격기류 시스템의 최적탈진조건에 관한 실험적 연구 (Experimental study on the optimum pulse jet cleaning conditions of a rectangular bag-filter system)

  • 박승욱;김태형;이효우;하현철;정재훈
    • 한국산업보건학회지
    • /
    • 제18권3호
    • /
    • pp.189-203
    • /
    • 2008
  • Cylindrical bag filter system with pulse jet cleaning has been the most common device to control particle laden exhaust gas from the various industrial processes. But, it has many shortcomings due to particle reattachment and frequent bag rupture. In recent years, rectangular type bag filter system has been developed to overcome the problems associated with the cylindrical system. However, not many studies about the rectangular system were not done, compared to the cylindrical system. In this study, the optimum pulse jet cleaning conditions were thus tested by the series of experiments. The factors tested in this study are pulse distance, pulse pressure, pulse duration, the number of holes for pulsing and bag materials. A single bag ($1,500mmL{\times}50mmW{\times}300mmH$) system and a multi-bags (3 bags in a row) were tested separately. The highest removal efficiency with a single bag system was found at the conditions with pulse distance of 10cm, pulse pressure of $3kg/cm^2$, pulse duration of 0.3s, pulse jet number of 6 and Polyester bag. With the multi-bags system, the best cleaning conditions were found at the bag interval of 20cm with the simultaneous pulsing and the bag interval of 15cm with the serial pulsing.

밧데리 전원을 이용한 고압 펄스 전원 장치 개발 (Development of a High Voltage Pulse Power Supply with Battery Source)

  • 강유리
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2000
  • With the increasing demands for clean environment development of air cleaning systems has been received increasing attention. Pulse power systems are widely used for air cleaning in the industrial applications. High voltage pulse power supply affects the performance of the overall environmental system. In this study high voltage micro pulse power supply for removing NOx in diesel engines is developed. The ratings of the pulse voltage is 20kV. The pulse width is 10usec and max. pulse repetition ratio is 1kHz.

  • PDF

고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구 (A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration)

  • 김장우;정진도;김은권
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

세라믹필터 집진장치의 역세정 시스템 설계를 위한 유동해석 (A Numerical Analysis of Pulse-Jet Cleaning Characteristics for Ceramic Filter System Design)

  • 정재화;서석빈;김시문;안달홍;김종진
    • 에너지공학
    • /
    • 제12권3호
    • /
    • pp.197-206
    • /
    • 2003
  • 본 연구에서는 다공성 세라믹 필터를 사용하는 집진장치에서 역세정 과정의 유동특성을 규명하고, 역세정 시스템 설계에 적용하기 위한 전산해석을 수행하였다. 주요 연구내용으로는 역세정 과정에서 중요한 변수인 노즐 직경, 노즐 팁의 위치, 다공성 세라믹 캔들필터의 투과율, 디퓨저 형상, 역세정 압력 등이 집진장치 내부에서의 속도분포, 압력분포 등 역세정 유동특성에 미치는 영향을 상세히 계산하여 역세정 시스템의 사양 설계에 활용할 수 있도록 하였다. 전산해석에는 상용의 FLUENT code를 사용하여 에너지 보존식을 포함한 압축성 축대칭 Navier-Stokes 방정식을 유한체적법 (Finite volume method)으로 해석하였다.

LCD 세정용 상압 플라즈마 전원장치 (Power Supply for LCO Cleaning Plasma)

  • 조형기;김규식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.282-284
    • /
    • 2006
  • UV lamp systems have been used for cleaning of display pannels of TFT LCD or Plasma Display Pannel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques be developed and improved. In this paper, 3kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, bi-directional high voltage pulse switching circuits are used to generate the high voltage plasma.

  • PDF