• Title/Summary/Keyword: pulse analyzer

Search Result 153, Processing Time 0.025 seconds

Characteristics in W-EDM of Tungsten Carbide (초경합금의 와이어 방전가공에 의한 특성)

  • 맹민재
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.7-13
    • /
    • 2001
  • Wire electrical discharge machining experiments in conducted to investigate characteristics of acoustic emission (AE) and electrical discharge energy due to current peak (I$_{p}$), pulse on time($\tau$/on/). The AE signals are obtained with a sensor attached to workpiece side. Machining states are identified with scanning electron microscopy and residual stress analyzer. It is demonstrated that the residual stress provide reliable informations about the machining states. Moreover, machining states can be detected successfully using both the residual stress and AE count rate.e.

  • PDF

Pilot Study on Variation of Menstruating Women's Pulse Energy in Left and Right Chon, Kwan, Cheok (월경기 여성의 맥파 변화에 대한 예비 연구)

  • Lee, Ji-Yeon;Yoo, Jeong-Eun;Yun, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.140-149
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the change and correlation of pulse energy in Left and Right Chon, Kwan, Cheok during menstruation, especially around menstruation start date. Methods: The subjects of this experiment were 8 healthy women whose menstruation periods are regular. We measured 3D Blood Pressure Pulse Analyzer (3D-MAC) tests before and after menstruation start date. Results: The results were as follows 1. The pulse energy of the Right Chon was significantly decreased and Left Kwan was comparatively increased during the next day of menstruation start date than previous day. 2. There was a negative correlation between Left Kwan and Left Cheok, Right Chon and Right Kwan pulse energy during the previous and menstruation start date. The negative correlation disappeared between Right Chon and Right Kwan at the next day of menstruation start date. Conclusions: The results suggest that Chon, Kwan, Cheok pulse energy changes are related to menstruation and reflect physiological mechanism of menstruating women. Further study will be needed.

Design of Solid-State Transmitter and Receiver for Active Array Radar System (능동 배열 레이더 시스템 구현을 위한 반도체형 송수신기 설계)

  • Lee, Yu-Ri;Kim, Jong-Pil;Lee, Soo-Ho;Jeong, Myung-Deuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1335-1342
    • /
    • 2010
  • This paper presents design and measurement result of S-band, $\bigcirc$ kW solid-state transmitter and receiver for active array radar system. Transmitter characteristics show 63 dB gain, 200 usec pulse width(max.), 10 % duty(max.) and 63 dB pulse to pulse stability. Receiver characteristics show 23 dB gain and 3.2 dB noise figure. Receiving mode for pulse network analyzer is used for pulse to pulse stability measurement. Measurement results satisfies all specification.

A Study on Relationship between Hot Flush and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer in Women Who Complain of Perimenopausal and Postmenopausal Syndrome (갱년기증후군 환자의 안면홍조 증상과 맥 에너지와의 상관성 연구)

  • Bae, Ju-Eun;Lee, Hee-Yoon;Son, Bo-Gil;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.4
    • /
    • pp.1-12
    • /
    • 2016
  • Objectives: The purpose of this study is to analyze the correlation between the pulse energy and hot flush in women who complain of climacteric syndrome. Methods: We analyzed the values of pulse energy on 78 of perimenopausal and postmenopausal women. The symptoms of patients were assessed by Kupperman’s index (KI) and Menopause Rating Scale (MRS). Statistical analysis was performed by Spearman correlation coefficient and student T-test, using SPSS 18.0 for window program. Results: The results were as follows. 1. There were no statistically significant relation between pulse energy of left Cheok subtracted from left Chon and KI, MRS hot flush score. 2. When divided depending on MRS hot flush score, There were no statistically significant differences on pulse energy. Conclusions: The results suggest that there is no correlation between hot flush score and pulse energy.

Development of Software Interpolator for Two-Axis Contouring Control (2축 윤곽제어를 위한 소프트웨어 보간자 개발에 관한 연구)

  • 김교형;이기설
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.389-396
    • /
    • 1988
  • Microprocessor-based software DDA interpolator is developed and applied to two axis contouring control of X-Y table. Developed assembly program is composed of feedrate, linear and circular DDA interpolation routines. Reference-pulse type of open-loop stepping motor control system in which the micro-computer produces a sequence of reference pulses for each axis of motion is adopted. To test performance of the developed program, X-Y table drive system based on stepping motor and shaft encoder is designed. Conturing error of the system in linear and circular path is within .+-. 0.2mm under start stop pulse rate of stepping motor.

A study on the Optimum Conditions of Nd:YAG LBW for Zircaloy-4 End Cap Closure By Optical Fiber Transmission (광섬유전송에 의한 Zircaloy-4 봉단마개밀봉의 Nd:YAG LBW의 최적조건에 관한 연구)

  • 김수성;김웅기;이영호
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.85-95
    • /
    • 1997
  • This study is to investigate the optimum conditions of Nd:YAG laser beam welding for Zircaloy-4 end cap closure by optical fiber transmission. Laser welding parameters which affect the penetration depth and bead width were experimentally examined using the various beam radius by the beam quality analyzer, joint geometries of end cap and the laser parameters which mean pulse width, repetition rate and pulse energy. Also, an optimum welding speed and the effect of assistant gas with varying the flow rate of He were investigated. We found that the laser average power for the end cap welding will be 230W and rotation speed must not exceed 8 RPM, the best position of focus using optical fiber with 600.mu.m will be 2 to 3mm below the surface of the material.

  • PDF

Improvement and Limitations in the Sasang Constitution Diagnosis by the Instrument-based Pulse Diagnosis (맥진을 이용한 사상체질 판별 방법의 개선 및 의의)

  • Kim, Jae-Uk;Kim, Sung-Hun;Lee, Yu-Jung;Jeon, Young-Ju;Kim, Keun-Ho;Kim, Jong-Yoel
    • Korean Journal of Oriental Medicine
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2009
  • Recently, there have been emerging research activities in classifying the Sasang constitution objectively by machine-based methods. The concordance rate of the classification by the pulse wave features was, however, only around 50% up to now. In this paper, we introduce a novel classification algorithm that can promote the accuracy substantially at the expense of the non-classifiable subgroup as a byproduct. For instance, with the pulse wave features alone, we show that female/male subject group in their 20s can be classified into the Sasang constitution group with the concordance rate of 68.4%/65.5% for a subgroup of 57/29(31%/15%) subjects out of 184/195, by leaving the other subjects as the non-classifiable group. Next, we show that the pulse diagnosis has been used only as a supportive tool in determining one's constitution, and consequently the accuracy of the concordance ratio by the pulse wave features alone cannot exceed a finite value, which we estimate to be about 60%.

  • PDF

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects (당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Park, Su-Jeong;Kim, Kyung-Yo;Lee, Si-Woo;Kwon, Young-Mi;Kil, Eun-Young;Joo, Jong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.

Partial Discharge Electromagnetic Wave Penetration Characteristics Throughout Transformer Winding (전자기파 부분방전 신호의 권선 투과 특성)

  • Ju, Hyung-Jun;Han, Ki-Son;Yoon, Jin-Yul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.10
    • /
    • pp.809-813
    • /
    • 2010
  • Frequency domain measurement of propagation loss for ultra high frequency (UHF) partial discharge in the winding of power transformer using a spectrum analyzer and pulse generator is presented. We compared the performance of the method using a network analyzer with and without a winding. Using a network analyzer simplifies the measurement and offers better dynamic range and frequency range. It also provides precise propagation loss within the winding in frequency domain at UHF range. We applied this method to measure UHF propagation loss of transformer mock-up, modeled 154 kV 20 MVA power in KEPCO substation.

Development of the pulse analyzing system using FBG (FBG를 이용한 맥진 시스템 개발)

  • Jeon, Young-Ju;Lee, Jeon;Ryu, Hyun-Hee;Lee, Jae-Hoon;Lee, Si-Woo;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • This work reports the pulse diagnosis system using FBG sensors which can display pulse signals detected while oriental medical doctors are conducting pulse diagnoses and simultaneously pressing the sensors by three fingers. Each optical fiber has five FBG sensing units fabricated in 2 mm width and 2 mm inter-sensor spacing. Three optical fibers with the FBG units in the parallel line configuration are then placed on each finger-pressing region and thus overall 9 fibers are used for the pulse measurements on the so-called "chon", "gwan", and "ch대k". A fixture holding the optical fiber arrays is able to adjust the height of the FBG sensing units while placing the fibers on the wrist. The pulse signals detected by the FBG sensors from chon, kwan, and chuk have been analyzed using 4 channel spectrum analyzer connected to the optical fibers. The measured pulse signals exhibit variations due to the nonuniform pressure distributions applied. resulting in the differences in the detected pulse signals between fiber lines. However. this work is the first step towards objective and quantitative analyses of the pulse diagnosis in oriental medicine which has traditionally been performed on subjective basis. Future works will be devoted to improving sensor stability, developing the way applying pressure and algorithms reporting the objective classification of the pulse status from systemic measurements using the sensors instead of relying on the clinicians' diagnoses subjectively performed. A successful pulse diagnosis system emerging in the future is expected to contribute to education as well as promoting pulse diagnosis in oriental medicine to the scientific research area.

  • PDF