• Title/Summary/Keyword: pulse 시간

Search Result 1,004, Processing Time 0.021 seconds

Studies on the Mathematical Modelling of the Pulse-CVI for the Infiltration of Siliconcarbide from Methyltrichlorosilane (메틸삼염화규소로부터 탄화규소 침착의 Pulse-CVI에 대한 수치모사 연구)

  • Kim, In-Goo;Kim, Min-Ki;Chung, Gui-Yung
    • Composites Research
    • /
    • v.18 no.5
    • /
    • pp.27-33
    • /
    • 2005
  • In this research, the mathematical modelling of the pulse-CVI (Chemical Vapor Infiltration) for the preparation of siliconcarbide/carbon composite. Each pulse consists with the gas injection time, the reaction time and the evacuation time. Effects of the reaction time and the evacuation time were studied. Additionally, the effects of the reactant concentration and the pressure were observed. The benefits of the pulse-CVI such as the uniform infiltration of siliconcarbide into the carbon preform and the short reaction time were certified.

The New Type Pulse Generator Adopted Cascading Technique (소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성)

  • Kyung-Ae Shin;Whi-Young kim;Myeong-Soon Kim
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.3
    • /
    • pp.363-368
    • /
    • 2001
  • This paper introduced cascading technique as a new technology composed of two pulse transformers and presented the experimental data and results. To obtain the stable pulse voltage adopted cascading technique, we designed and tested a compact pulse generator by adjusting the load resistors and input voltage. Adopting cascading technique to load, we found that average cascading voltage was about 62$\%$ of theoretical value. Cascading ratio was calculated at almost 19 compared with non cascading voltage.

  • PDF

Pulse Protocol-based Hybrid Reader Anti-collision Algorithm using Slot-occupied Probability under Dense Reader Environment (밀집 리더 환경 하에서 슬롯 점유확률을 이용한 Pulse Protocol 기반의 Hybrid 리더 충돌방지 알고리즘)

  • Song, In-Chan;Fan, Xiao;Yoon, Hee-Seok;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.10A
    • /
    • pp.987-996
    • /
    • 2008
  • In this paper, the conventional anti-collision algorithms, such as Channel Monitoring algorithm and Pulse Protocol algorithm are analyzed. To decrease tag identification time, and increase system throughput and efficiency, we propose a new reader anti-collision algorithm, Pulse Protocol-based Hybrid Reader Anti-collision Algorithm, using Slot-occupied Probability under dense reader environment. The proposed algorithm uses Slot-occupied Probability to improve the performance of Pulse Protocol Algorithm. That is, A reader checks Slot-occupied Probability after generating random backoff time. If Slot-occupied Probability is greater than 0, it uses another new random backoff time to avoid reader collision. We also compare the performance of the proposed algorithm with those of Channel Monitoring and Pulse Protocol algorithms in respect of identification time system throughput, and system efficiency. Simulation results show that the proposed algorithm has an increment of 5% of identification time and system throughput as increasing the number of readers.

Error Analysis of Reaction Wheel Speed Detection Methods Due to Non-uniformity of Tacho Pulse Duration (타코 펄스 불균일성이 존재하는 반작용휠의 속도측정 방법 오차 분석)

  • Oh, Shi-Hwan;Yong, Ki-Lyuk
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.92-97
    • /
    • 2009
  • Two conventional speed detection methods (Elapsed-time method and Pulse-count method) are analyzed and compared for a high speed motor with digital tacho pulse with non-uniformity. In general, the elapsed-time method usually has better performance than a pulse-count method in case sufficiently high speed clock is used to measure the time difference. But if a tacho pulse non-uniformity exists in the reaction wheel - most of reaction wheel has a certain amount of non-uniformity - the accuracy of the elapsed-time method is degraded significantly. Thus the performance degradation is analyzed with respect to the level of non-uniformity of tacho pulse distribution and an allowable bound is suggested.

  • PDF

Relationship between sleep duration and pulse pressure in Korean adults: Focusing on the data of the 7th National Health and Nutrition Survey (한국 성인의 수면시간과 맥압과의 관련성: 국민건강영양조사 제7기 자료를 중심으로)

  • Jung, Eun-Young
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.411-418
    • /
    • 2022
  • The purpose of this study is to investigate the relationship between sleep time and pulse pressure in Korean adults, and the research method used data from the 7th period (2016-2018) of the National Health and Nutrition Examination Survey. Subjects were 5,707 persons aged 20 years or older, and for frequency and percentage continuous data, mean and standard deviation, cross analysis and independent t-test, and stepwise logistic regression analysis for high pulse pressure were performed. SPSS WIN 18.0 version statistical program was used. was used. As a result of the study, the prevalence of hypertension was higher in the overall population (OR=1.344, 95% CI=1.002-1.803) and in women (OR=1.624, 95% CI=1.112-2.371) when sleeping for more than 9 hours compared to less than 6 hours. high, but not significant in males (OR=1.012, 95% CI=0.631-1.550). Therefore, considering the effects of inappropriate sleep time on health, public health education and management are necessary. Further research on the relationship between sleep time and pulse pressure will be needed.

Measurement and Analysis of Pulse Wave using Clip Type Pulsimeter Equipped with a Permanent Magnet and a Hall Device (영구자석과 홀소자로 구비된 집게형 맥진기를 이용한 맥진파형 측정과 분석)

  • Son, Il-Ho;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.3
    • /
    • pp.104-107
    • /
    • 2011
  • We measured signals at the "Guan" region of a radially arterial pulse using the prototype of a clamping pulsimeter equipped with a Hall effect device, which is passed signals through the voltage detecting hard ware system. The important four different measuring times of the period, systolic, reflective, and notch peaks for a temporally pulse signal are obtained and compared each other from the analysis for an arbitrary pulse wave of one position of small size permanent magnet. It is possible to measure the reproducible pulse rate and blood pressure by using the cuffless clip type pulsimeter without an unpleasant oppressive feeling due to the use of pressurization.

Basic and Advanced MR Pulse Sequence - Fundamental Understanding-

  • 장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.15-29
    • /
    • 2002
  • MRI에서 펄스 시퀀스(pulse sequence)란 고주파 RF(radiofrequency) 펄스 및 경사자장(gradient) 펄스를 가하고 MR 신호를 획득하는 순서를 시간대별로 도식화 한 pulse diagram을 이야기한다. 이러한 pulse sequence는 실제로 영상을 획득하기 위한 RF amplifier, gradient amplifier 등의 하드웨어를 순차적(sequential)으로 구동하는 역할을 한다. 따라서 이러한 pulse sequence는 현재 임상적으로 사용되는 다양한 영상기법들을 이해하는데 필수적이다.

  • PDF

Mobile PULSE : A Routing Protocol Considering the Power and the Route Recovery Time in Sensor Networks with A Mobile Sink Node (모바일 PULSE : 모바일 싱크 노드를 가진 센서 네트워크에서의 경로 복구 시간과 전력 소모량을 고려한 라우팅 프로토콜)

  • Lee, Chi-Young;Lee, Shin-Hyoung;Yoo, Chuck
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.2B
    • /
    • pp.151-161
    • /
    • 2009
  • The PULSE protocol can greatly reduce power consumption using a node's sleep state. But this protocol does not consider movement of a sink node in a sensor network. In the mobile sensor network a routing protocol must recover path error by movement of a sink node as quickly as possible. Therefore we have to achieve fast path recovery and power saving to support movement of a sink node in a sensor network. This paper proposes the Mobile PULSE protocol which is a improved routing protocol for a mobile sink node. And we evaluate Mobile PULSE and show that the Mobile PULSE reduces the recovery time about 40% compared with original PULSE protocol. Mobile PULSE increases energy consumption than PULSE as a maximum of 0.8%, which means Mobile PULSE is similar to PULSE in energy consumption. This paper shows mobile PULSE's capability in the mobile sensor network through evaluation of path recovery time and power consumption.

Direct blast detection algorithm for asynchronous bistatic sonar systems (비동기 양상태 소나 시스템을 위한 직접파 탐지 기법)

  • Jeong, Euicheol;Ahn, Jae-Kyun;Kim, Juho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.139-146
    • /
    • 2018
  • Monostatic sonar systems localize targets using the time information of pulse transmission and receipt. Whereas, in asynchronous bistatic sonar systems, receivers need to detect direct blast to localize targets, since a source doesn't share pulse information with receivers. In this paper, we propose a direct blast detection algorithm, which estimates PRI (Pulse Repetition Interval) of direct blast and adaptive thresholds. Experimental results show the proposed algorithm has robust direct blast detection performance in the environment where strong background noise and target signal exist.

Higher-order soilton puliton pulse generation and compression in dispersion decreasing fiber for optical time division multiplexing system source applications (분산감소광섬유에서의 고차 솔리통 펄스 생성 및 압축을 통한 광시간분할다중시스템 광원의 제작에 대한 연구)

  • 이덕기;김나영;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.102-107
    • /
    • 2000
  • We propose a new scheme for generating a pedestal-free, femtosecond soliton pulse train by utilizing quasI-adiabatic high order soliton pulse evolution in dispersion decreasing fiber in conjunction with the intermediate pedestal suppression stage. Compression factor over 280 was achieved from lOGHz sinusoidal input, to 176 is soliton pulse train. train.

  • PDF