• Title/Summary/Keyword: pullout load

Search Result 134, Processing Time 0.025 seconds

Bond Performance of Steel to Concrete subjected to Cyclic Loading (반복하중시 철근의 마디형태에 따른 부착특성)

  • 이재열;이웅세;최완철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.545-550
    • /
    • 2000
  • Bond between reinforcing bars and the surrounding concrete is supposed to safely transfer load in the design process of reinforced concrete structures. Bar with high relative rib area will be studied further not only static load but also dynamic loading conditions to sustain better performance of bond for reinforced concrete structures under earthquake. To determine the bond behavior of high ribbed bars in beam and column joints under repeated loads, 31 pullout specimens were tested. Bond strength increases as relative rib area increases. Also the effect of relative rib area on bond is larger in cyclic loading than in monotonic loading.

  • PDF

Pullout Capacity of Ground Anchors in Weathered Soil (풍화토 지반에 설치된 앵커의 인발 특성)

  • 김낙경
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.231-239
    • /
    • 2001
  • 건설 현장에서 널리 사용되고 있는 그라운드 앵커의 거동 특성을 연구하기 위하여 계측기를 부착한 일곱 개의 그라운드 앵커를 국내에 널리 분포되어 있는 화강 풍화토 지반인 $\bigcirc$$\bigcirc$$\bigcirc$대학교 지반 시험장에 설치하여 인발 시험을 수행하였다. 저압 그라우트 인장형 앵커 3개와 압축형 앵커 4개를 시험하였고, 시험은 AASHTO 규정에 의거한 인발시험, 크리프시험, 장기거동시험을 수행하였다. 시험 결과로부터 화강 풍화토 지반에 설치된 저압그라우트 직선형 앵커의 지반과의 마찰계수, 크리프 변형율, 하중감소 특성을 평가하였다.

  • PDF

Expansion Ratio of Pulse Power Underreamed Anchor (펄스방전 그라운드 앵커의 확공 특성에 관한 연구)

  • Kim, Nak-Kyung;Ju, Yonh-Sun;Kim, Sung-Kyu;Seo, Hyo-Kyun;Kim, Sun-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.1107-1112
    • /
    • 2009
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this study, a series of field test were carried out in order to find expansion rate related in number of pulse charge. and Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to define a relation between expansion rate and ultimate pullout load.

  • PDF

Study on Pullout Behavior and Determination of Ultimate Uplift Capacity of Pile Driven in Small Pressured Chamber (소형 압력 토조내에 타입된 말뚝의 인발 거동과 극한 인발 지지력 결정에 관한 연구)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-28
    • /
    • 1995
  • Based on the various test data acquired in the field, the large pressure chamber and the small pressure chamber, uplift behaviors and method of determining the ultimate uplift capacity of pile driven in small pressure chamber were studied. After uplift pile experienced 2 or 3 sudden slip due to increase of uplift load, complete pullout failure was occurred. Thus, it appears that the ultimate uplift capacity could be identified as the load at displacement where first slip occurs. The ultimate uplift capacity might be determined in every test and the disturbance after first uplift test could be recovered by adding one blow of the drop hammer, which had to depend on the model pile capacity.

  • PDF

A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip (가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구)

  • Lee, Sang-Min;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.1
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

Performance Evaluation of Rockfall Prevention Net Using Laboratory Pullout Test (실내인발시험을 이용한 낙석방지망 성능평가)

  • Kim, TaeSik;Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.11-16
    • /
    • 2020
  • It is necessary to assess the proper performance of the existing rockfall prevention net in order to minimize the damage to human lives and property in the event of rockfall. However, there is no standard for performance evaluation of rockfall prevention net in Korea, and only the design of rockfall prevention net exists by calculating energy that can be absorbed energy. Therefore, laboratory pullout test was conducted for the performance evaluation of the rockfall prevention net, cuts and load-displacement characteristics of the PVC coating net used in the laboratory pullout test are determined to identify the performance of the rockfall prevention net.

Effect of Mineral Admixture on Bond Properties between Polyolefin Based Synthetic Fiber and Cement Mortar (폴리올레핀계 합성 섬유와 시멘트 모르타르와의 부착 특성에 미치는 광물질 혼화재의 효과)

  • Lee, Jin-Hyeong;Park, Chan-Gi
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.339-346
    • /
    • 2011
  • The effects of mineral admixtures on the bonding properties of cement mortar to polyolefin based synthetic fiber were evaluated. The mineral admixtures consisted of 0%, 5%, 10%, and 15% fly ash, blast furnace slag, and metakaolin in cement. Bond interactions between the cement mortar and the polyolefin based synthetic fiber were determined by Dog-bone bond tests. Bond tests of the polyolefin based synthetic fiber showed an increase in pullout load with the strength of the cement mortar. Also, the interface toughness of polyolefin based synthetic fiber in cement mortar increased as the fly ash, blast furnace slag, and metakaolin contents increased. The microstructure of polyolefin based synthetic fiber surface was examined after the pullout test to analyze the frictional resistant force according to the replacement ratio of fly ash, blast furnace slag, and metakaolin during the pullout process of polyolefin based synthetic fiber in cement mortar. The scratched of polyolefin based synthetic fibers increased with the replacement ratio of fly ash, blast furnace slag, and metakaolin. Also, the interface toughness was enhanced by adhesion forces induced by the fly ash, blast furnace slag, and metakaolin.

Load Transfer Mechanism of Hybrid Model of Soil-nailing and Compression Anchor (쏘일네일링과 앵커가 결합된 하이브리드 공법의 하중전이 메커니즘)

  • Seo, Hyung-Joon;Kim, Hyun-Rae;Han, Shin-In;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • The load transfer mechanism of hybrid model of soil-nailing and compression anchor is studied in this paper. The hybrid model is composed of an anchor bar (installed at the tip) with two PC strands and a steel bar. It can make active behavior of skin friction by applying the pre-stress. In this paper, the load transfer mechanisms of soil-nailings, compression anchors, and hybrid models, respectively, are obtained from skin friction theory and load transfer theory. Field pullout tests are performed to identify the load transfer mechanism and experimental results are compared with analytical solution. In case of soil-nailings, the tension load is transferred from face to tip, however, in case of compression anchors, the compression load is transferred from tip to face. The experimental behavior of the hybrid model is similar to that of compression anchor when only pre-stress is applied. If the pullout test is performed by simultaneously pulling out the anchor and the nail, the compression load is dominant at the tip and tension load is dominant at the face. The load transfer mechanism of the hybrid model shows the combined behavior of soil-nailings with compression anchors.

Creep of Plate Anchors Embedded in Bentonite (Bentonite에 근입된 앵커의 Creep 특성)

  • Shin, B.W.;Lee, J.D.;Shin, J.H.;Lee, B.J.
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.3-8
    • /
    • 1995
  • Anchors find their use in providing tie-back resistance for submerged footings, transmission towers, tunnels and ocean structures. Laboratory model teats were performed for the short-term net ultimate uplift capacity of a circular anchors with respect to various embedment depths and moisture content in saturated bentonite. The tests have been conducted with the anchor at two different moisture contents. Based an the model test results, empirical relationships between the net load, rate of strain, and time have been developed. Test results are as follows. 1) In creep tests for load versus ultimate uplift capacity, the displacement of plate anchors rapidly increases during the primary stage but thereafter becomes constant over a period of time. 2) Displacement increased with the increase of the sustain load and embedded ratio in soil. 3) If the load is less than or equal to 75% of the short-term ultimate uplift capacity, a complete pullout does not occur due to creep.

  • PDF

Reinforcement Bulb Body Pull-out Resistance Force Behavior Characteristics according to Ground Conditions (지반조건에 따른 보강구근체 인발저항력 거동 특성)

  • An, JunYoung;Shim, JeongHoon;Jeong, JiSu;Lee, SeungHo
    • The Journal of Engineering Geology
    • /
    • v.27 no.1
    • /
    • pp.41-49
    • /
    • 2017
  • In this study, we tried to confirm the influence range in the ground due to Bulbed, Reinforcement change and ground conditions change through numerical analysis. By checking the increase width of the reinforcement effect accompanying the increase of Bulbed, grasping the trend accompanying the change of the ground conditions and deciding soil nail Reinforcement and Bulbed, so that economical construction will be carried out It can be judged that it can be utilized as basic material. In this paper, we analyzed the Displacement due to positional load of reinforcement by utilizing MIDAS GTS NX which is a universal numerical analysis program. In addition, it is necessary to ensure the diameter star economy of Bulbed size and Reinforcement by comparing / analyzing whether the Bulbed relaxation region of Reinforcement represents arbitrary characteristics in the ground in Sandy soil, Weathered granite soil ground due to soil nail pullout load Numerical analysis was conducted to select criteria that can be done.