• 제목/요약/키워드: pull-in instability

검색결과 15건 처리시간 0.021초

Pull-in instability of electrically actuated poly-SiGe graded micro-beams

  • Jia, Xiao L.;Zhang, Shi M.;Yang, Jie;Kitipornchai, Sritawat
    • Coupled systems mechanics
    • /
    • 제2권3호
    • /
    • pp.215-230
    • /
    • 2013
  • This paper investigates the pull-in instability of functionally graded poly-SiGe micro-beams under the combined electrostatic and intermolecular forces and temperature change. The exponential distribution model and Voigt model are used to analyze the functionally graded materials (FGMs). Principle of virtual work is used to derive the nonlinear governing differential equation which is then solved using differential quadrature method (DQM). A parametric study is conducted to show the significant effects of material composition, geometric nonlinearity, temperature change and intermolecular Casimir force.

A semi-analytical study on the nonlinear pull-in instability of FGM nanoactuators

  • Attia, Mohamed A.;Abo-Bakr, Rasha M.
    • Structural Engineering and Mechanics
    • /
    • 제76권4호
    • /
    • pp.451-463
    • /
    • 2020
  • In this paper, a new semi-analytical solution for estimating the pull-in parameters of electrically actuated functionally graded (FG) nanobeams is proposed. All the bulk and surface material properties of the FG nanoactuator vary continuously in thickness direction according to power law distribution. Here, the modified couple stress theory (MCST) and Gurtin-Murdoch surface elasticity theory (SET) are jointly employed to capture the size effects of the nanoscale beam in the context of Euler-Bernoulli beam theory. According to the MCST and SET and accounting for the mid-plane stretching, axial residual stress, electrostatic actuation, fringing field, and dispersion (Casimir or/and van der Waals) forces, the nonlinear nonclassical equation of motion and boundary conditions are obtained derived using Hamilton principle. The proposed semi-analytical solution is derived by employing Galerkin method in conjunction with the Particle Swarm Optimization (PSO) method. The proposed solution approach is validated with the available literature. The freestanding behavior of nanoactuators is also investigated. A parametric study is conducted to illustrate the effects of different material and geometrical parameters on the pull-in response of cantilever and doubly-clamped FG nanoactuators. This model and proposed solution are helpful especially in mechanical design of micro/nanoactuators made of FGMs.

경골극 골절의 관절경적 치료 후 슬관절의 전방 불안정성 (Anterior Instability of the Knee after Arthroscopic Treatment for Tibial Spine Fractures)

  • 최종혁;김성환;주종환;김형식
    • 대한관절경학회지
    • /
    • 제10권1호
    • /
    • pp.26-32
    • /
    • 2006
  • 목적: 경골극 골절에서 관절경을 이용한 골편의 정복 및 고정 후 골절편의 정복 정도와 전방 불안정성에 대한 결과를 알아보고자 하였다. 대상 및 방법: 경골극 골절로 관절경적 치료를 받은 32예를 대상으로 하였으며 평균 추시 기간은 18개월(12개월-48개월)이었다. 수술 후 평가는 Lachman 검사 및 회전 불안정성 검사와 KT-2000 관절측정기를 이용한 건측과의 전방전위차이(SSD)를 측정하였다. 방사선 사진 상 골편의 완전 정복, 전방 거상 및 정복 실패로 나누었고, 골편의 정복 정도에 따른 전방 불안정성 정도를 조사하였다. 결과: 골편의 완전 정복, 전방 거상, 정복 실패는 각각 23예(71%), 8예(25%), 1예(4%)였고 pull-out 방법 28예 중 8예(29%)에서 전방 거상이 있었다. 완전 정복군과 전방 거상군의 SSD는 각각 2.0 mm와 2.8mm로 의미 있는 차이는 없었으나 Lachman 0등급 비율(P=0.021)과 3 mm 미만의 SSD의 비율(P=0.048)은 의미 있게 정복군이 높았다. 결론: 심하게 전위된 골절일수록 골편의 정확한 정복이 술 후 전방 동요를 줄이는데 중요할 것으로 생각되며, 봉합사를 이용한 pull-out 방법에 의한 고정은 수술 후 골편 전방부의 거상을 유발할 수 있으므로 세심한 주의가 필요 할 것으로 생각된다.

  • PDF

열가소성 폴리머 필름의 마이크로 점착 거동에 대한 온도의 영향 (Effect of Temperature on the Micro-scale Adhesion Behavior of Thermoplastic Polymer Film)

  • 김광섭;허정철;김경웅
    • Tribology and Lubricants
    • /
    • 제25권2호
    • /
    • pp.86-95
    • /
    • 2009
  • Adhesion tests were carried out in order to investigate the effect of temperature on the adhesion behavior between a PMMA film and a fused silica lens in the micro scale. For the tests, a microtribometer system was specially designed and constructed. The pull-off forces on the PMMA film were measured under atmospheric condition as the temperature of the PMMA film was increased from 300 K to 443 K and decreased to 300 K. The contact area between the PMMA film and the lens was observed during the test. The adhesion behavior was changed with the change of the PMMA surface state as the temperature increased. In glassy state below 363 K, the pull-off force did not change with the increase of temperature. In rubbery state from 383 K to 413 K, the pull-off force increased greatly as the temperature increased. In addition, the area of contact was enlarged. In viscous state above 423 K, the fingering instability was observed in the area of contact when the PMMA film contacted with the lens. It was also found that the adhesion behavior can be varied with the thermal history of the PMMA film. The residual solvent in the PMMA film could emerge to the PMMA surface due to the heating and reduced the pull-off force.

Interfacial instability of Boger fluid in the pull-off test between two circular plates

  • Kang Hyoung Mi;Kim Chongyoup
    • Korea-Australia Rheology Journal
    • /
    • 제16권4호
    • /
    • pp.219-226
    • /
    • 2004
  • In this study the deformation of liquid-air interface of Newtonian or Boger fluids filled between two par­allel-plates geometry was investigated when two surfaces were separated at a constant speed. The interface between the fluid and air showed either stable or unstable deformation depending on experimental con­ditions. Repeated experiments for a wide range of experimental conditions revealed that the deformation mode could be classified into three types: 'stable region', 'fingering' and 'cavitation'. The experimental condition for the mode of deformation was plotted in a capillary number vs. Deborah number phase plane. It has been found that the elasticity of Boger fluids destabilize the interface deformation. On the other hand, the elasticity suppresses the formation and growth of cavities.

Dynamical behaviour of electrically actuated microcantilevers

  • Farokhi, Hamed;Ghayesh, Mergen H.
    • Coupled systems mechanics
    • /
    • 제4권3호
    • /
    • pp.251-262
    • /
    • 2015
  • The current paper aims at investigating the nonlinear dynamical behaviour of an electrically actuated microcantilever. The microcantilever is excited by a combination of AC and DC voltages. The nonlinear equation of motion of the microcantilever is obtained by means of force and moment balances. A high-dimensional Galerkin scheme is then applied to reduce the equation of motion to a discrete model. A numerical technique, based on the pseudo-arclength continuation method, is used to solve the discretized model. The electrostatic deflection of the microcantilever and static pull-in instabilities, due to the DC voltage, are analyzed by plotting the so-called DC voltage-deflection curves. At the simultaneous presence of the DC and AC voltages, the nonlinear dynamical behaviour of the microcantilever is analyzed by plotting frequency-response and force-response curves.

통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계 (High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy)

  • 박철원;원철희
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

역도 인상동작 불안정성 수준에 따른 발바닥 체성감각요인 분석 (Factor Analysis of the Somatosensory for Foot according to the Instability Level of Snatch Lifting)

  • Moon, Young Jin
    • 한국운동역학회지
    • /
    • 제30권1호
    • /
    • pp.7-16
    • /
    • 2020
  • Objective: It is to find factors related to stability through analysis of plantar pressure factors according to the level of instability when performing Snatch. Method: Foot pressure analysis was performed while 10 weightlifters performed 80% of the highest level of Snatch, and motion was classified and analyzed in 3 grades according to the level of instability. Results: First, in Bad Motion, the movement distance of the pressure center in the direction of ML and AP was larger significantly in Phase 2. Second, in Phase 2, the number of zero-crossing in the AP direction was larger statistically significantly in Good Motion. Third, in the bad motion in Phase 3, the number of zero-crossing in the ML direction showed a significantly larger value. Fourth, in Phase 4, it was found that the more stable the lock out motion, the greater the activity of foot controlling in the left and right directions. Fifth, Phase 3, the greater the Maximum/Mean foot pressure value, the more stable the pulling action. Sixth, in Phase 2, the foot pressure was concentrated with a wide distribution in the midfoot and rearfoot. Seventh, the triggering number of the forefoot region was small in the last pull phase. Eighth, the number of triggers in the toe area was significantly higher during Good Motion in Phase 4. Conclusion: Summarizing the factors of instability in Snatch, there was no significant difference in Phase 1 for each condition. In order to enhance the stability in Phase 2, the sensory control ability in the AP direction is required, and focusing the foot pressing motion with a wide distribution in the middle and rear parts increases the instability. In Phase 3, it was found that the more unstable, the more sensory control activity was performed in the ML direction, the stronger the forefoot pressing action should be performed for a stable Snatch. In Phase 4, It is important that the feet sensory control activity in ML directions and the control ability of the toes in order to have stable Lock out motion.

가스 하이드레이트 탄성파 자료에 대한 중합전 심도 구조보정 (Prestack depth migration for gas hydrate seismic data set)

  • 도안후이히엔;장성형;김영완;서상용
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.564-568
    • /
    • 2007
  • Gas hydrate has been attractive topic for two dedicates because it may cause the global warming, ocean hazards associated with the instability of marine slope due to the gas hydrate release as well as high potential of future energy resources. The study on gas hydrate in Ulleung basin has been performed since 1999 to explore the potential and distribution of gas hydrate offshore Korea. The numerous multi channel seismic data have been acquired and processed by Korea Institute of Geosciences and Mineral Resources (KIGAM). The results showed clearly the gas hydrate indicators such as pull up structure, bottom simulating reflector (BSR), seismic blanking zone. The prestack depth migration has been considered as fast and accurate technique to image the subsurface. In this paper, we will present both the conventional seismic data processing and apply Kirchhoff prestack depth migration for gas hydrate data set. The results will be applied for core sample collections and for proposal more detail 2D with long offset or 3D seismic exploration.

  • PDF

도관 나사못을 이용한 경골 과간 융기 골절의 관절경적 견인 봉합술 (Arthroscopic Pull-out Wire Fixation Using Cannulated Screw of Tibial Eminence Fractures)

  • 김종민;김형규;박병문;송경섭;정성훈;노행기;윤종주
    • 대한관절경학회지
    • /
    • 제13권3호
    • /
    • pp.254-258
    • /
    • 2009
  • 경골 과간 융기부 골절은 슬관절의 뒤틀림, 과도한 굴곡 및 신전, 내반 및 외반 손상으로 인한 견열 골절의 형태로 발생을 하며 정확한 해부학적 정복이 이루어지지 않을 경우 슬관절의 불안정성과 관절 운동 제한을 초래할 수 있다. 최근 관절경을 이용한 정복과 다양한 고정 방법이 시행되고 있으며, 저자들은 이 중 견인 봉합술을 시행함에 있어서 도관 나사못을 이용한 터널을 만들어 기존에 시행되어지던 술기에 비해 보다 쉽고 편리하게 내고정을 얻을 수 있었으며, 이에 수술방법의 소개와 증례를 보고하고자 한다.

  • PDF