• Title/Summary/Keyword: protocol testing

Search Result 251, Processing Time 0.029 seconds

A FRF-based algorithm for damage detection using experimentally collected data

  • Garcia-Palencia, Antonio;Santini-Bell, Erin;Gul, Mustafa;Catbas, Necati
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.4
    • /
    • pp.399-418
    • /
    • 2015
  • Automated damage detection through Structural Health Monitoring (SHM) techniques has become an active area of research in the bridge engineering community but widespread implementation on in-service infrastructure still presents some challenges. In the meantime, visual inspection remains as the most common method for condition assessment even though collected information is highly subjective and certain types of damage can be overlooked by the inspector. In this article, a Frequency Response Functions-based model updating algorithm is evaluated using experimentally collected data from the University of Central Florida (UCF)-Benchmark Structure. A protocol for measurement selection and a regularization technique are presented in this work in order to provide the most well-conditioned model updating scenario for the target structure. The proposed technique is composed of two main stages. First, the initial finite element model (FEM) is calibrated through model updating so that it captures the dynamic signature of the UCF Benchmark Structure in its healthy condition. Second, based upon collected data from the damaged condition, the updating process is repeated on the baseline (healthy) FEM. The difference between the updated parameters from subsequent stages revealed both location and extent of damage in a "blind" scenario, without any previous information about type and location of damage.

Experimental characterization of timber framed masonry walls cyclic behaviour

  • Goncalves, Ana Maria;Ferreira, Joao Gomes;Guerreiro, Luis;Branco, Fernando
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.189-204
    • /
    • 2015
  • After the large destruction of Lisbon due to the 1755 earthquake, the city had to be almost completely rebuilt. In this context, an innovative structural solution was implemented in new buildings, comprising internal timber framed walls which, together with the floors timber elements, constituted a 3-D framing system, known as "cage", providing resistance and deformation capacity for seismic loading. The internal timber framed masonry walls, in elevated floors, are constituted by a timber frame with vertical and horizontal elements, braced with diagonal elements, known as Saint Andrew's crosses, with masonry infill. This paper describes an experimental campaign to assess the in-plane cyclic behaviour of those so called "frontal" walls. A total series of 4 tests were conducted in 4 real size walls. Two models consist of the simple timber frames without masonry infill, and the other two specimens have identical timber frames but present masonry infill. Experimental characterization of the in-plane behaviour was carried out by static cyclic shear testing with controlled displacements. The loading protocol used was the CUREE for ordinary ground motions. The hysteretic behaviour main parameters of such walls subjected to cyclic loading were computed namely the initial stiffness, ductility and energy dissipation capacity.

Literature Review of Nursing Intervention Studies for Patients Undergoing Percutaneous Coronary Intervention (경피적 관상동맥 중재술 환자에게 적용된 간호중재 연구 고찰)

  • Baek, Kyoung Hwa;Son, Youn-Jung
    • Perspectives in Nursing Science
    • /
    • v.12 no.2
    • /
    • pp.82-93
    • /
    • 2015
  • Purpose: This study aimed to provide a systematic review of the evidence from controlled trials regarding nursing intervention studies on patients undergoing percutaneous coronary intervention, a discussion of the methodological problems that limit current research, and suggestions regarding future directions for research. Methods: Using a predefined protocol, 27 electronic databases were searched, studies selected, relevant data extracted, and the methodological quality of the studies assessed. Results: Twenty-seven studies were found reporting complex, generally heterogeneous interventions. The studies reported positive results, including self-efficacy, knowledge, and self-care. There were 6 randomized controlled trials, 19 quasi-experimental studies, and 2 only research group studies. In addition to support components, the interventions included elements of teaching, counseling, and education. Nursing interventions are still in the developmental and testing phase. Conclusion: The review demonstrated that a great deal is known about nursing intervention, the impact on a range of outcomes, and methodology. Although some useful evidence was reported for all interventions, further research needs to be carried out.

Design and Implementation of Hadoop-based Big-data processing Platform for IoT Environment (사물인터넷 환경을 위한 하둡 기반 빅데이터 처리 플랫폼 설계 및 구현)

  • Heo, Seok-Yeol;Lee, Ho-Young;Lee, Wan-Jik
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.2
    • /
    • pp.194-202
    • /
    • 2019
  • In the information society represented by the Fourth Industrial Revolution, various types of data and information that are difficult to see are produced, processed, and processed and circulated to enhance the value of existing goods. The IoT(Internet of Things) paradigm will change the appearance of individual life, industry, disaster, safety and public service fields. In order to implement the IoT paradigm, several elements of technology are required. It is necessary that these various elements are efficiently connected to constitute one system as a whole. It is also necessary to collect, provide, transmit, store and analyze IoT data for implementation of IoT platform. We designed and implemented a big data processing IoT platform for IoT service implementation. Proposed platform system is consist of IoT sensing/control device, IoT message protocol, unstructured data server and big data analysis components. For platform testing, fixed IoT devices were implemented as solar power generation modules and mobile IoT devices as modules for table tennis stroke data measurement. The transmission part uses the HTTP and the CoAP, which are based on the Internet. The data server is composed of Hadoop and the big data is analyzed using R. Through the emprical test using fixed and mobile IoT devices we confirmed that proposed IoT platform system normally process and operate big data.

An Appraoch for Preserving Loaction Privacy using Location Based Services in Mobile Cloud Computing

  • Abbas, Fizza;Hussain, Rasheed;Son, Junggab;Oh, Heekuck
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.621-624
    • /
    • 2013
  • Mobile Cloud Computing is today's emerging technology. Customers enjoy the services and application from this combination of mobile technology and cloud computing. Beside all these benefits it also increases the concerns regarding privacy of users, while interacting with this new paradigm One of the services is Location based services, but to get their required services user has to give his/her current location to the LBS provider that is violation of location privacy of mobile client. Many approaches are in literature for preserve location privacy but some has computation restriction and some suffer from lack of privacy. In this paper we proposed a novel idea that not only efficient in its protocol but also completely preserves the user's privacy. The result shows that by sharing just service name and a large enough geographic area (e.g. a city) user gets required information from the server by doing little client side processing We perform experiments at client side by developing and testing an android based mobile client application to support our argument.

Commercial ECU-Based Test-Bed for LIN-CAN Co-Analysis and Proof on Ultrasonic Sensors through Physical Error Injection (실차기반 LIN-CAN 연계 통합 분석 테스트베드 개발과 초음파센서 물리적 오류주입 및 분석을 통한 효용성 검증)

  • Yoon-ji Kim;Ye-ji Koh;In-su Oh;Kang-bin Yim
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.325-336
    • /
    • 2023
  • With the development of autonomous driving technology, the number of external contact sensors mounted on vehicles is increasing, and the importance is also rising. The vehicular ultrasonic sensor uses the LIN protocol in the form of a bus topology and reports a status message about its surroundings through the vehicle's internal network. Since ultrasonic sensors are vulnerable to various threats due to poor security protocols, physical testing on actual vehicle is needed. Therefore, this paper developed a LIN-CAN co-analysis testbed with a jig for location-specific distance test to examine the operational relation between LIN and CAN caused by ultrasonic sensors.

Conformance Test Platform for the Protocol based on TTCN-3 (TTCN-3 기반 적합성 시험기 플랫폼)

  • Yong-Gi Jang;Byeong-Kwon Song;Yae-Eui Jeong;Gun-Woong Kim;Jin-chul Kim;Young-eok Kim
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.11a
    • /
    • pp.1232-1235
    • /
    • 2008
  • TTCN-3(Testing & Test Control Notation Version 3)은 국제 표준 테스팅 언어이다. TTCN-3는 다양한 통신 프로토콜이나 장치간의 연동성을 검증하기 위한 적합성 시험을 할 수 있고, 프로토콜이나 통신 장치가 표준에 적합하게 구현되었는지를 검증할 수 있다. 본 논문에서는 TTCN-3을 사용하여 종단과 종단간의 연결설정의 확립의 인증성 시험에 대한 프로토콜 장치간의 상호 여동성을 보장하기 위한 적합성 시험을 제안하고, 산호 연동성 시험과 장치에 구현된 프로토콜이 표준 구격에 적합한지를 시험하는 예를 시험한다.

Evaluation of Efficacy and Risk of Intradermal Skin Testing for Antibiotic Pharmacotherapy in Hospital of Korea (한국 병원의 항생제 치료를 위한 항생제피부반응시험에 대한 유효성 및 위험성 평가)

  • Kim, Kyeong Ha;Lee, Yun Jeong;Lim, Sung Cil
    • YAKHAK HOEJI
    • /
    • v.58 no.4
    • /
    • pp.229-244
    • /
    • 2014
  • Background: Antibiotic skin test(AST) is very useful for the diagnosis of drug allergies to prevent immediate allergic reactions. Although it is a safe and widespread method, it is performed very diversely by doctors and nurses without consistency and it also differs from countries and hospitals. This study aims to evaluate the current practice of AST by nurses in Korea and to compare it to the general guidelines. Methods: During January 1, 2013 to May 20, 2013, the study was conducted as questionnaires and case-based survey. The questionnaires were given to the nurses who were randomly selected in various University Hospitals (University Hospitals N=276, and Medical center N=19). The case-based surveys were given to the nurses who were conducting AST at various wards of a University Hospital (N=130). The analysis and evaluations of the responses were carried out. Results: The response rate for the questionnaires was 97.6% and 130 cases of the actual case-based surveys were collected. There were clear differences between the survey results and the general guidelines, such as the method of skin test (skin prick test was not conducted), the method of patient selection for AST, test drugs, concentration, volume and interpretation of AST. AST conducted by nurses was highly variable and inconsistent, even among nurses who worked in the same wards and hospitals. Manufactured standard concentration antibiotic solution of AST showed consistency of concentration to a certain degree. Conclusion: Although the general guidelines have been published by several countries including Korea, these are not a great help to nurses as they lack details for conducting AST, practical consideration for nurses in the clinical setting, propagation and education. Standardized guideline for nurses should be published and it should be a safe, clear, comfortable and easily accessible protocol. Futhermore, additional antibiotic solutions to standardize skin test should be developed and manufactured. Lastly, it would be the pharmacists role to compare their hospitals antibiotic skin test methods with the standard guidelines and develop a protocol within the hospital for patients' safety, and to strive to consistently implement it.

Constructing Software Structure Graph through Progressive Execution (점진적 실행을 통한 소프트웨어의 구조 그래프 생성)

  • Lee, Hye-Ryun;Shin, Seung-Hun;Choi, Kyung-Hee;Jung, Gi-Hyun;Park, Seung-Kyu
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.7
    • /
    • pp.111-123
    • /
    • 2013
  • To verify software vulnerability, the method of conjecturing software structure and then testing the software based on the conjectured structure has been highlighted. To utilize the method, an efficient way to conjecture software structure is required. The popular graph and tree methods such as DFG(Data Flow Graph), CFG(Control Flow Graph) and CFA(Control Flow Automata) have a serious drawback. That is, they cannot express software in a hierarchical fashion. In this paper, we propose a method to overcome the drawback. The proposed method applies various input data to a binary code, generate CFG's based on the code output and construct a HCFG (Hierarchical Control Flow Graph) to express the generated CFG's in a hierarchical structure. The components required for HCFG and progressive algorithm to construct HCFG are also proposed. The proposed method is verified through constructing the software architecture of an open SMTP(Simple Mail Transfer Protocol) server program. The structure generated by the proposed method and the real program structure are compared and analyzed.

Development of DAP(Dose Area Product) for Radiation Evaluation of Medical and Industrial X-ray generator (의료 및 산업용 X-선 발생장치의 선량평가를 위한 면적선량계(DAP) 개발)

  • Kwak, Dong-Hoon;Lee, Sang-Heon;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.495-498
    • /
    • 2018
  • In this paper, we propose an DAP system for dose evaluation of medical and industrial X-ray generator. Based on the DAP measurement technique using the Ion-Chamber, the proposed system can clearly measure the exposure radiation dose generated by the diagnostic X-ray apparatus. The hardware part of the DAP measures the amount of charge in the air that is captured by an X-ray. The high-speed processing algorithm part for cumulative radiation dose measurement through microcurrent measures the amount of charge captured by X-ray at a low implementation cost (power) with no input loss. The wired/wireless transmission/reception protocol part synchronized with the operation of the X-ray generator improves communication speed. The PC-based control program part for interlocking and aging measures the amount of X-ray generated in real time and enables measurement graphs and numerical value monitoring through PC GUI. As a result of evaluating the performance of the proposed system in an accredited testing laboratory, the measured values using DAP increased linearly in each energy band (30, 60, 100, 150 kV). In addition, since the standard deviation of the measured value at the point of 4 division was ${\pm}1.25%$, it was confirmed that the DAP showed uniform measurements regardless of location. It was confirmed that the normal operation was not less than ${\pm}4.2%$ of the international standard.