• Title/Summary/Keyword: protocol inspection

Search Result 65, Processing Time 0.028 seconds

Analysis of Disinfection Practices in Foodservice Operations According to the Application of Hazard Analysis and Critical Control Point (식품안전관리인증기준 적용 여부에 따른 급식시설의 소독 실태 분석)

  • Park, Min-Seo;Lee, Hye-Yeon;Bae, Hyun-Joo
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.103-110
    • /
    • 2021
  • This study was conducted to compare and evaluate the difference in washing and disinfection when the Hazard Analysis and Critical Control Point (HACCP) protocol was applied to foodservice operations. The results of the survey were as follows: Among the 116 foodservice operations surveyed, 67.2% were HACCP-compliant and 32.8% were not HACCP-compliant. Also, 62.9% served meals once daily, and 79.3% conducted food safety education once a month. Compared to HACCP non-compliant foodservice operations, the disinfection performance of HACCP-compliant operations was significantly better concerning worktables (p<0.001), food inspection tables (p<0.001), preparation tables for distribution (p<0.01), serving tables (p<0.01), overflow and trenches(p<0.05), sinks (p<0.05), and insect attracting lamps (p<0.01). Similarly, the disinfection performance of HACCP-compliant foodservice operations was significantly better for 18 cooking utensils and personal tools such as food slicers (p<0.001), multiple cooking machines (p<0.05), tray carts (p<0.001), stainless steel tools (p<0.001), rubber gloves (p<0.05). Worktables (45.1%), serving tables (29.6%), sinks (37.0%), and scales (21.6%) were most often disinfected 'at the end of each task', while food inspection tables (36.5%), food preparation tables for distribution (31.2%), dish machines (34.2%), overflow and trenches (25.7%), and floors (25.8%) were most often disinfected 'once a day'. All cooking utensils were most often disinfected 'at the end of each task'. 'Chemical disinfection' was most frequently used in all foodservice facilities. To improve the food safety management of foodservice operations, it is necessary to apply the HACCP protocol and comply with the washing and disinfection manual.

An Evaluation of Usefulness of FEES Method using Full HD Video that Improves Diagnostic Value of VFSS (Full HD 동영상을 이용한 FEES법이 VFSS의 진단적 가치를 향상 시키는 유용성에 대한 평가)

  • Kim, Young-Ran;Kim, Young-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.678-685
    • /
    • 2016
  • Deglutition inspection has been the gold standard for inspection of dysphagia using a penetration device of the division of radiology to date. However, inspection using an endoscope has facilitated diagnosis of dysphagia in recent days. In this study, we compared the results of VFSS alone with those of VFSS combined with FEES to determine if the detection rate of penetration, aspiration, and pharyngeal residue increased. This study evaluated at 130 persons who underwent both VFSS and FEES from December 2013 through March 2014, and used VFSS (FELAVISION, SHIMADZU) and FESS (EVIU LUCERA CV-260SL, OLYMPUS) as devices. After preparing barium diluted solution, yogurt that diluted barium and rice that diluted barium in 2.5 ml, 5 ml, 10 ml by modifying Logemann's protocol in part, and having subjects take the solution, this study confirmed pharyngeal residue, penetration, aspiration etc. VFFS and FEES using full HD video revealed aspiration in 36 of the 130 patients in both inspections. Additionally, aspiration was discovered in 36 patients upon VFFS, but in 41 upon FESS. Although FEES was more sensitive at diagnosing dysphagia, the two inspection methods are complementary, so diagnostic value will be greatly improved when the endoscope operating method and accurate fluoroscopic inspection are combined.

Software Design of Packet Analyzer based on Byte-Filtered Packet Inspection Mechanism for UW-ASN

  • Muminov, Sardorbek;Yun, Nam-Yeol;Park, Soo-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.12
    • /
    • pp.1572-1582
    • /
    • 2011
  • The rapid growth of UnderWater Acoustic Sensor Networks (UW-ASNs) has led researchers to enhance underwater MAC protocols against limitations existing in underwater environment. We propose the customized robust real-time packet inspection mechanism with addressing the problem of the search for the data packet loss and network performance quality analysis in UW-ASNs, and describe our experiences using this approach. The goal of this work is to provide a framework to assess the network real-time performance quality. We propose a customized and adaptive mechanism to detect, monitor and analyze the data packets according to the MAC protocol standards in UW-ASNs. The packet analyzing method and software we propose is easy to implement, maintain, update and enhance. We take input stream as real data packets from sniffer node in capture mode and perform fully analysis. We were interested in developing software and hardware designed tool with the same capabilities which almost all terrestrial network packet sniffers have. Experimental results confirm that the best way to achieve maximum performance requires the most adaptive algorithm. In this paper, we present and offer the proposed packet analyzer, which can be effectively used for implementing underwater MAC protocols.

Development of Confocal Imaging System for Wafer Inspection (개발 웨이퍼 검사위한 Confocal 이미징 시스템의 개발)

  • Ko, Kuk-Won;Nguyen, Cong Dai;Koh, Kyung-Cheol
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.108-112
    • /
    • 2010
  • Confocal Imaging System is an essential machine for a wide range of inspection wafer. For concurrent and fast acquiring the image data of four channels, the new image acquisition system used the protocol of camera-link standard with the full mode of configuration in interconnection with a frame grabber integrated in a computer, which is popularly used for many cameras, so the programming environment of image processing is optional such as Visual C++, Matlab. In addition, many conventional methods were coordinately used for contribution to build the high quality of images for precise processing analog signals of PhotoMutiplier Tubes(PMTs), accurate control of scanning device, sensitivity of PMTs, and laser source. The prototype of new image acquisition system, could meet the goal of development, it is used in LSCM for high content screening to investigation the processes of elements of living specimens at the same time by simultaneous grab image data on 4 PMTs channels.

  • PDF

A Designing Method of Digital Forensic Snort Application Model (Snort 침입탐지 구조를 활용한 디지털 Forensic 응용모델 설계방법)

  • Noh, Si-Choon
    • Convergence Security Journal
    • /
    • v.10 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • Snort is an open source network intrusion prevention and detection system (IDS/IPS) developed by Sourcefire. Combining the benefits of signature, protocol and anomaly-based inspection, Snort is the most widely deployed IDS/IPS technology worldwide. With millions of downloads and approximately 300,000 registered users. Snort identifies network indicators by inspecting network packets in transmission. A process on a host's machine usually generates these network indicators. This means whatever the snort signature matches the packet, that same signature must be in memory for some period (possibly micro seconds) of time. Finally, investigate some security issues that you should consider when running a Snort system. Paper coverage includes: How an IDS Works, Where Snort fits, Snort system requirements, Exploring Snort's features, Using Snort on your network, Snort and your network architecture, security considerations with snort under digital forensic windows environment.

A Study on Design of Real-time Big Data Collection and Analysis System based on OPC-UA for Smart Manufacturing of Machine Working

  • Kim, Jaepyo;Kim, Youngjoo;Kim, Seungcheon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.121-128
    • /
    • 2021
  • In order to design a real time big data collection and analysis system of manufacturing data in a smart factory, it is important to establish an appropriate wired/wireless communication system and protocol. This paper introduces the latest communication protocol, OPC-UA (Open Platform Communication Unified Architecture) based client/server function, applied user interface technology to configure a network for real-time data collection through IoT Integration. Then, Database is designed in MES (Manufacturing Execution System) based on the analysis table that reflects the user's requirements among the data extracted from the new cutting process automation process, bush inner diameter indentation measurement system and tool monitoring/inspection system. In summary, big data analysis system introduced in this paper performs SPC (statistical Process Control) analysis and visualization analysis with interface of OPC-UA-based wired/wireless communication. Through AI learning modeling with XGBoost (eXtream Gradient Boosting) and LR (Linear Regression) algorithm, quality and visualization analysis is carried out the storage and connection to the cloud.

Analysis of Spiramycin in Fish Using High Performance Liquid Chromatography (HPLC를 이용한 어류 중의 Spiramycin 분석)

  • Lee Tae-Seek;Lee Hee-Jung;Jo Mi-Ra;Byun Han-Seok;Son Kwang-Tae;Park Mi-Jung;Yi Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.2
    • /
    • pp.78-84
    • /
    • 2006
  • A high performance liquid chromatography assay method for spiramycin in fish muscle was developed. The developed method was evaluated and validated by monitoring spiramycin in olive flounder (Paralichthys olivaceus), black rock fish (Sebastes schlegeli) and in live conger eel (Anguilla japonica) in fish farms and distribution centers. Using the developed method, the recovery rate was up to 82.4-88.8%, which was higher than that of conventional methods (77.6-87.1%). In particular, the proposed sample treatment protocol was suitable for use with fish samples to remove low molecular weight materials and pigments that could interfere an accurate analysis. The prepared stock solution was very stable, and it remained chemically stable for 5 weeks at $4^{\circ}C$. The performance limit of the developed method for spiramycin acid in fish muscle was 0.05 ppm. One hundred thirty-four fish samples including olive flounder, black rock fish and live conger eel were analyzed to evaluate the overall efficiency of the modified method and to monitor the actual condition of spiramycin usage in fish farms. Olive flounder and black rock fish were collected from fish farms in coastal areas of Korea, and live conger eels were purchased from a fish market in the Busan area from September 2001 to March 2002. According to the overall performance of the developed method, it was considered suitable for the monitoring of spiramycin in fish muscle. The suggested method of analysis for spiramycin in fish muscle is registered in the Korean Official Methods of Food Analysis and is currently tieing utilized for fishery products inspection by the Korea Food and Drug Administration and the National Fisheries Products Quality Inspection Service.

VLSI Design for Automatic Magnetizing and Inspection System (자동착자 및 검사자동화 시스템을 위한 집적회로 설계)

  • Im, Tae-Yeong;Lee, Cheon-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.7
    • /
    • pp.1929-1940
    • /
    • 1999
  • In this paper a VLSI design for the automatic magnetizing and inspection system has been presented. This is a design of a peripheral controller, which magnetizes CRTs and computer monitors and controls the automatic inspection system. We implemented a programmable peripheral interface(PPI) circuit of the control and protocol module for the magnetizer controller by using a 0.8um CMOS SOG technology of ETRI. Most of the PPI functions have been confirmed. In the conventional method, the propagation/ramp delay model was used to predict the delay of cells, but used to model on only a single cell. Later, a modified "linear delay predict model" was suggested in the LODECAP(LOgic DEsign CAPture) by adding some factors to the prior model. But this has not a full model on the delay chain. In this paper a new " delay predict equation" for the design of the timing control block in PPI system has been suggested. We have described the detail method on a design of delay chain block according to the extracted equation and applied this method to the timing control block design. And we had descriptions on the other blocks of this system.

  • PDF

Implementation of Real-time Monitoring System for Marine Elevator using Smart Sensors (스마트 센서를 이용한 선박용 승강기 실시간 모니터링 시스템의 구현)

  • Lee, WooJin;Yim, JaeHong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.405-410
    • /
    • 2016
  • Elevator industry is a field that is mechanical, electrical and electronic technology and constantly requires inspection and maintenance considering various applications and various types. Recently, various elevator control and monitoring technologies with IT are developing for elevators on land. But technologies with IT have been hardly done in marine elevator that is consistently assured safety and reliability of life cycle for its parts in poor environment. In this paper, we implemented embedded main controller, floor controller and car controller that meet the requirements and use NMEA network protocol by analyzing home and abroad integrated elevator operation and management systems. Especially, we secured reliability of maintenance by real-time fault diagnosis and control that was implemented with limit switch, gyro sensor, temperature/humidity/barometric pressure sensor and fire detection sensor thinking over the environmental conditions of terrestrial and marine elevator.

Implementation of an Integrated Monitoring System for Industrial Equipments with Different Network Protocols using ETOS-l00A (범용 게이트웨이 시스템(ETOS-l00A)을 이용한 이기종 통신 산업기기의 통합 모니터링 시스템 구축)

  • 정장식;안현식
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2537-2540
    • /
    • 2003
  • In this paper, an integrated monitoring system is implemented for industrial equipments which use different types of network protocols to communicate with other equipments. Dedicated gateway systems mate it difficult to modify or to add contents of network systems for communication with other systems. We suggest an integration method of effectively utilizing the general purpose gateway system (ETOS-l00A) which converts various types of protocols into TCP/IP protocol. To demonstrate the validity of the proposed integrated monitoring system, PLC-based automated inspection system is considered and the monitoring system is implemented using Visual Basic and HMI software.

  • PDF