• 제목/요약/키워드: protection switching time

검색결과 35건 처리시간 0.021초

형광램프용 전자식 스타터의 개발 (Development of an Electronic Starter for Fluorescent Lamps)

  • 정영춘;곽재영;여인선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1996년도 추계학술발표회논문집
    • /
    • pp.49-52
    • /
    • 1996
  • This paper reports the development of an electronic starter for fluorescent lamps, which is so smartly designed that can be used directly in existing installations. The key point of the design lies in the protection of lamp filaments by sufficient preheating and at the same time in the control of time constant for start-up circuit. The starter is consisted of three system parts: a rectifier pact, a switching part. and a gate control part. The characteristics of the developed electronic starter is compared with those of a conventional glow starter. As a result, blackening of lamps is almost reduced due to the stable and idealized start-up characteristics. And, furthermore, it is shown that its slaving time is shortened at about half the level of the conventional one and the starting power is also reduced.

  • PDF

$SF_6$ 가스중 V-t절연파괴특성 (Voltage Time characteristic of electrical breakdown in $SF_6$)

  • 서길수;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

Identification of Inrush and Internal Fault in Indirect Symmetrical Phase Shift Transformer Using Wavelet Transform

  • Bhasker, Shailendra Kumar;Tripathy, Manoj;Kumar, Vishal
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1697-1708
    • /
    • 2017
  • This paper proposes an algorithm for the differential protection of an Indirect Symmetrical Phase Shift Transformer (ISPST) by considering the different behaviors of the compensated differential current under internal fault and magnetizing inrush conditions. In this algorithm, a criterion function is defined which is based on the difference of amplitude of the wavelet transformation over a specific frequency band. The function has been used for the discrimination between three phase magnetizing inrush and internal fault condition and requires less than a quarter cycle after disturbance. This method is independent of any coefficient or threshold values of wavelet transformation. The merit of this algorithm is demonstrated by the simulation of different faults in series and excitation unit and magnetizing inrush with varying switching conditions on ISPST using PSCAD/EMTDC. Due to unavailability of in-field large interconnected transformers for such a large number of destructive tests, the results are further verified by Real Time Digital Simulator (RSCAD/RTDS). The proposed algorithm has been compared with the conventional harmonic restraint based method that justifies the application of wavelet transform for differential protection of ISPST. The proposed algorithm has also been verified for different rating of ISPSTs and satisfactory results were obtained.

항공 데이터버스용 링크 우회방식을 가진 고장감내 이더넷 시스템의 성능 분석 (Performance of Fault-tolerant Ethernet System with Link-bypass scheme for Airbone Databus)

  • 송대연;윤종호;정한균;김승환
    • 대한전자공학회논문지TC
    • /
    • 제44권9호
    • /
    • pp.46-53
    • /
    • 2007
  • 일반적인 이더넷 브리지망에서의 링크장애복구는 Spanning Tree Protocol(STP) 또는 Rapid STP에 의존하여 왔다. 그러나, 이러한 STP는 기본적인 복구지연시간 때문에 항공기제어와 같은 실시간 서비스에 필요한 신속한 장애 복구기능을 제공하지 못한다. 본 논문에서는 BcN의 백본 장비간의 내고장성을 제공하는 ITU-T의 Automatic Protection Switching(APS)기술과 최근 A380에 항공기용 데이터버스로 기본 장착되고 있는 ARINC 664의 Avionic Full Duplex Switched Ethernet(AFDX)의 성능을 비교한 후, AFDX기술의 성능 향상을 위하여 기존 AFDX망을 메쉬 형태로 모든 스위치들을 연결하고, 링크 장애 발생 시 장애가 발생한 링크를 우회하여 데이터를 전송하여 고장 감내 기능을 향상시킬 수 있는 링크 우회 기법을 제안하였다. 제안된 방법의 성능을 비교 검증하기 위하여 NS-2를 사용하여 기존의 이더넷과 AFDX, APS 및 제안된 기법을 모의실험하였다. 이러한 AFDX기술은 항공기뿐만 아니라 일반적인 BcN 백본망이나 산업자동화 통신망에서도 적용될 수 있는 특징이 있을 것이다.

홍수 및 수질 오염 감시용 지능형 고속 광 통신 시스템 개발에 관한 연구 (The study on the development of intelligent optical communication system to monitor flood and water pollution)

  • 이진영
    • 디지털융복합연구
    • /
    • 제10권11호
    • /
    • pp.351-358
    • /
    • 2012
  • 본 연구는 강유역의 홍수 및 수질 오염을 보다 효율적으로 관리하기 위해 고품질의 영상정보를 고속으로 전달할 수 있는 광통신 장치로 기존의 장치에 비해 저렴하면서도 네트워크 광선로 및 장비상태를 실시간으로 모니터링이 가능한 시스템을 제안한다. 홍수 통제용으로 이용되는 통신장비는 주로 무인함체 내에 설치되어 있고 이는 장거리 구간의 강 하구에 위치한 홍수 통제소에서 운용하고 있기 때문에 광 케이블의 절단이나 노화 등에 의한 통신 장해 발생시 신속한 대처가 어려운 문제가 있다. 따라서, 본 연구에서는 광 선로를 이용하여 고품질의 영상정보를 고속으로 전달할 수 있으면서도 위와 같은 사고 발생시 1차적으로 이중화 광 케이블 보호절체 기능을 이용하여 문제를 해결하고, 실시간 모니터링 기능으로 발생 지점을 실시간으로 통보해줌으로써 보다 효율적인 관리가 가능한 시스템을 제안하였다. 또한, 제안된 시스템은 지능형 교통 시스템 등 다양한 분야에서 폭넓게 활용이 가능할 것으로 판단된다.

유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구 (A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage)

  • 정성교;이재경;김한도;최대길;강용철;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책 (The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection)

  • 안상필;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권11호
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

NGN에서 QoS 제공을 위한 GMPLS의 라우팅 및 시그널링 화장 연구 (A Study of Routing and Signaling Extensions of GMPLS for QoS Provision in NGN)

  • 장석기;박광채
    • 한국정보통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.925-933
    • /
    • 2003
  • 네트워크는 IP 계층과 광 계층이 수렴되는 광인터넷 네트워크로 진화할 것으로 예상되나, 현재의 기술수준으로 인해 과도적인 진화단계로서 GMPLS가 대두되었다. MPLS가 확장되고 일반화된 GMPLS는 패킷 교환 장치뿐만 아니라 시간, 파장 및 공간 영역에서 교환을 수행하는 장치까지 지원할 수 있도록 하고 있다. 이런 다양한 스위칭 타입에 공통적인 제어 평면을 구현하기 위해 GMPLS에서는 기존의 MPLS 신호 및 라우팅 프로토콜을 확장하게된다. 본 논문에서는 GMPLS 기술의 개요와 MPLS에서 링크의 상태 정보를 교환하기 위해 사용되었던 OSPF(Open shortest Path First) 프로토콜을 광 네트워크에서 다양한 링크 타입, 대역폭, 링크 보호 타입 등의 정보를 주고받기 위한 라우팅 확장 방안에 대하여 알아보고, 두 노드간의 수백, 수천개의 링크를 관리하는 복잡한 문제를 해결하기 위한 신호 프로토콜로 LMP라는 새로운 프로토콜의 정의를 기술한다. 그리고 MPLS에서 트래픽 엔지니어링을 위한 신호 프로토콜인 RSVP-TE를 GMPLS에 적용하기 위한 신호 프로토콜의 확장 방안과 수정된 RSVP 관련 메시지들을 검토분석 한다.

Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권1호
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

펄스모드 스위칭 직류전원 장치에 적합한 AC/DC 켄버터 (AC/DC Converter Suitable for a Pulsed Mode Switching DC Power Supply)

  • 문상호;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.378-381
    • /
    • 2002
  • This paper describes a novel multilevel ad/dc power converter suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis and simulations are carried out to investigate the operation and usefulness of the proposed scheme.

  • PDF