• 제목/요약/키워드: protection panel

검색결과 176건 처리시간 0.025초

Roof tile frangibility and puncture of metal window shutters

  • Laboy-Rodriguez, Sylvia T.;Smith, Daniel;Gurley, Kurtis R.;Masters, Forrest J.
    • Wind and Structures
    • /
    • 제17권2호
    • /
    • pp.185-202
    • /
    • 2013
  • The goal of this study was to investigate the vulnerability of roof tile systems and metal shutters to roof tile debris. Three phases addressed the performance of tile roof systems and metal shutters impacted by roof tile debris. The first phase experimentally evaluated the tile fragment size and quantity generated by a tile striking a tile roof system. The second phase experimentally quantified the puncture vulnerability of common metal panel shutter systems as a function of tile fragment impact speed. The third phase provided context for interpretation of the experimental results through the use of a tile trajectory model. The results provide supporting evidence that while metal panel window shutters provide significant protection against a prevalent form of windborne debris, these systems are vulnerable to tile fragment puncture in design level tropical cyclones. These findings correlate with field observations made after Hurricane Charley (2004).

Electro-optical Characteristics of the Degraded Functional Layer in an Alternating- Current Plasma Display Panel

  • Lee, Kyung Ae;Min, Booki;Son, Chang Gil;Byeon, Yong S.;Yoon, Sang Ho;Choi, Eun Ha
    • Applied Science and Convergence Technology
    • /
    • 제24권6호
    • /
    • pp.232-236
    • /
    • 2015
  • The electro-optical characteristics of several functional layers over the MgO protective layer were studied during the continuous discharge of an AC-PDP. In order to observe the degradation of each functional layer on the MgO protection layer, we measured the surface morphology, cathodoluminescence (CL) spectrum, the secondary electron emission coefficient (${\gamma}$) and the discharge characteristics after 500 hours of discharge during the operation of the AC-PDP.

Numerical formulation of P-I diagrams for blast damage prediction and safety assessment of RC panels

  • Mussa, Mohamed H.;Mutalib, Azrul A.;Hao, Hong
    • Structural Engineering and Mechanics
    • /
    • 제75권5호
    • /
    • pp.607-620
    • /
    • 2020
  • A numerical study is carried out to assess the dynamic response and damage level of one- and two-way reinforced concrete (RC) panels subjected to explosive loads by using finite element LS-DYNA software. The precision of the numerical models is validated with the previous experimental test. The calibrated models are used to conduct a series of parametric studies to evaluate the effects of panel wall dimensions, concrete strength, and steel reinforcement ratio on the blast-resistant capacity of the panel under various magnitudes of blast load. The results are used to develop pressure-impulse (P-I) diagrams corresponding to the damage levels defined according to UFC-3-340-02 manual. Empirical equations are proposed to easily construct the P-I diagrams of RC panels that can be efficiently used to assess its safety level against blast loads.

투자자 보호제도가 은행들의 유동성위험에 영향을 미치는가? (Does Investor Protection Affect Bank Liquidity Risk?)

  • 이치선;김정심
    • 한국콘텐츠학회논문지
    • /
    • 제19권9호
    • /
    • pp.242-253
    • /
    • 2019
  • 2008년 글로벌 금융위기가 유동성위험에서 촉발되었으므로 금융위기 이후 유동성위험 관리방안에 대해 많은 연구들이 수행되었다. 그러나 투자자 보호 정도가 은행들의 유동성위험에 영향을 미치는지에 대해서는 전 세계적으로 아직 연구된 바가 없으므로 본 연구에서는 투자자 보호와 유동성위험과의 관계를 고찰하고 정책적 시사점을 도출하였다. 경제협력개발기구(OECD) 21개국 상업은행들을 대상으로 패널데이터를 구축하여 분석한 결과, 투자자에 대한 보호 수준이 높을수록 은행들의 유동성위험이 낮아짐을 발견하였다. 또한 투자자 보호의 이러한 긍정적 효과는 금융위기 기간 동안 더욱 강화되는 것으로 나타났다. 이는 금융위기 기간 동안 시행되는 강력한 경기부양책으로 인해 시장에 의한 규율이 약화된 상황에서 법적인 투자자 보호제도가 은행들의 건전성 제고에 기여할 수 있음을 시사한다.

중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구 (A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test)

  • 민세홍;김미숙
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

방사능 관련 일본산 수산물 수입 분쟁에 관한 SPS 협정 분석 (A Critical Analysis of the SPS Dispute over the Import Ban on Japanese Radioactive Seafood)

  • 윤정현;임송수
    • 무역학회지
    • /
    • 제44권4호
    • /
    • pp.19-34
    • /
    • 2019
  • This study investigates the WTO dispute over Japanese fishery products originated from Fukushima and another seven prefectures. Being subject to an import ban and additional radioactive test requirements, Japan complained that the Korean government's trade measures are inconsistent with the principles of the Agreement on Sanitary and Phytosanitary Measures. This paper considered the contrasting judicial decisions made by the Panel and Appellate Body and analyzed the debates with respect to their trade-discriminatory effects (Article 2.4), the relevance of appropriate level of protection (Article 5.6) and the precautionary approaches (Article 5.7). Consistent with the final rulings, this paper identifies the need for a broaden understanding of regional conditions and qualitative aspects of protection in risk analysis. Findings also suggest that Korea has diverted its fishery imports from Japan to other countries, while Japan has created export diversion from Korea to other destinations.

기업에서의 모성보호제도에 대한 연구 : 제도의 도입 및 현실과의 어긋남을 중심으로 (A Study on the Maternity Protection in Korean Companies : Focusing on the Adoption and Decoupling of Practices)

  • 구자숙
    • 한국조사연구학회지:조사연구
    • /
    • 제10권3호
    • /
    • pp.107-130
    • /
    • 2009
  • 본 연구는 최근 점차로 확산되고 있는 기업에서의 모성보호제도들에 대한 연구로서 기업들이 다양한 모성보호제도들을 도입하고 실행하는 데 영향을 미치는 요인들을 신제도주의적 관점에서 분석한다. 사업체패널 조사자료를 분석한 결과 공공부문에 속하거나, 해외 자본투자를 받은 기업들, 우수기업을 벤치마킹하는 기업들, 그리고 인적자원관리 전담부서가 있는 기업들이 모성보호제도의 도입 및 실행에 보다 적극적인 것으로 나타났다. 이러한 분석결과는 신제도주의에서 제시하는 정당성 획득을 위한 제도의 도입이 한국의 기업들이 모성보호제도를 도입하고 실행하는 데에도 중요하다는 함의를 갖는다. 저출산 및 성차별 문제를 해결하기 위해 모성보호제도를 확산시키는 데 있어 이러한 제도적 요인들에 대한 정부 및 관련 기관들의 고려가 중요하다는 것을 본 연구결과는 제시한다.

  • PDF

코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석 (Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection)

  • 김청균
    • 한국가스학회지
    • /
    • 제13권6호
    • /
    • pp.9-14
    • /
    • 2009
  • 본 연구에서는 LNG 저장탱크의 단열재 공간에 설치된 코너프로텍션에 작용하는 응력 및 변형거동 특성을 FEM으로 해석하였다. 제시된 코너프로텍션은 기존의 멤브레인식 LNG 저장탱크의 강도안 전성과 LNG 누출안전성을 증대시킬 수 있다. LNG 저장탱크 시스템에 작용하는 응력과 변위 거동량을 단열재 상자, 멤브레인 내부탱크, PC 외부탱크에 대하여 해석하였다. 유한요소법으로 계산한 해석결과에 의하면, 내부탱크와 외부탱크 사이에 코너프로텍션을 설치한 새로운 LNG 멤브레인 저장탱크의 응력과 변형 거동량은 기존의 LNG 저장탱크에 비하여 현저하게 줄어드는 경향을 보여주고 있다. 이러한 현상은 LNG 저장탱크 시스템의 강도 안전성이 코너프로텍션을 설치함에 따라서 강성도가 증가하기 때문인 것으로 설명될 수 있다.

  • PDF

반응성 R.F. 스퍼트링에 의한 AC PDP 용 MgO형성에 관한 연구 (The study on MgO formation for AC PDP prepared by R.F. reactive magnetron Sputtering)

  • 하홍주;이우근;남상옥;하석천;조정수;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1576-1578
    • /
    • 1996
  • MgO protection layer in ac PDP prevents the dielectric layer from sputtering of ion in discharge plasma in addition to the contribution to the memory function and also have the additional important roll in lowering the firing Voltage due to a large secondary electron emission yield(${\gamma}$). The methode of Sputtering are easy to apply on mass production and to enlarge the size of the panel and are known to have the superior Adhesion and Uniformity of thin film. MgO protection layer of $1000{\AA}$ on dielectric layer by Reactive R.F magnetron sputtering is formed. Discharge characteristics have done with the formation of protection layer.

  • PDF

경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성 연구 (Study on the Conduction Heat Transfer Characteristics According to the Heating Temperature of Lightweight Panel Wall material)

  • 박상민;이호성;최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.46-56
    • /
    • 2018
  • 본 논문은 경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성에 관한 연구이다. 경량칸막이 벽체재료로 사용되고 있는 대표적인 소재인 일반석고보드, 방화석고보드를 포함하여 합판, 대리석, 내열유리를 실험시료로 선정하였고, 수열온도를 $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$로 설정하였다. 그 후 벽체재료 하단부에 각각의 수열온도를 30분 동안 인가하여 상단부인 이면부로의 전도 열전달 특성을 분석하였다. 실험결과 수열온도가 최대 $600^{\circ}C$로 인가됨에 따라 최대 이면온도는 일반석고보드 $190^{\circ}C$, 방화석고보드 $198^{\circ}C$, 합판 $189^{\circ}C$, 대리석 $321^{\circ}C$, 내열유리 $418^{\circ}C$까지 측정되었다. 또한, 수열온도가 최대 $600^{\circ}C$로 인가됨에 따라 전도 열전달율의 최대 변화폭은 일반석고보드 85 W, 방화 석고보드 95 W, 합판 67 W, 대리석 1686 W, 내열유리 3196 W 까지 측정되었다. 추가적으로 전도 열전달의 위험성을 가시적으로 확인하기 위해 벽지의 탄화특성 측정결과 수열온도 $600^{\circ}C$의 경우 부착된 벽지의 최초연기발생은 일반석고 보드 1021 s, 방화석고보드 978 s, 합판 1395 s, 대리석 167 s, 내열유리 20 s에 나타났고, 최초탄화발생은 일반석고보드 1115 s, 방화석고보드 1089 s, 합판 1489 s, 대리석 192 s, 내열유리 36 s에 나타났다.