• Title/Summary/Keyword: protection panel

Search Result 176, Processing Time 0.032 seconds

Basic Study on Fiber Composite Panel Production for Impact·Blast Resistant (방호·방폭 보강용 복합섬유 패널 제작을 위한 기초연구)

  • Kim, Woonhak;Kang, Seokwon;Yun, Seunggyu
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.235-243
    • /
    • 2015
  • The methods to improve the protection and explosion-proof performance of concrete structures include the backside reinforcement or concrete material property improvement and the addition of structural members or supports to increase the resistance performance, but they are inefficient in terms of economics and structural characteristics. This study is about the basic study on the fiber composite panel cover, and the nano-composite material and adhesive as the filler, to maximize the specific performance of each layer and the protection and explosion-proof performance as the composite panel component by improving the tensile strength, light weight, adhesion and fire-proof performances. The fiber composite panel cover (aramid-polyester ratios of 6:4 and 6.5:3.5) had a 2,348 MPa maximum tensile strength and a 1.8% maximum elongation. The filler that contained the nano-composite material and adhesive had a 4 MPa maximum tensile shear adhesive strength. In addition, the nano-composite filler was 30% lighter than the normal portland cement

Precision analysis on the ISO 13784-1's Round Robin scenarios (ISO 13784-1 RRT 결과의 정밀도 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.333-336
    • /
    • 2012
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equlity of distribution also analyzed on the point of statistical view based on ISO.

  • PDF

Analysis on International Round Robin Test's Result by ISO 13784-1 Standard (ISO 13784-1 시험 방법에 의한 국제 상호비교 평가 분석)

  • Park, Kye-Won;Jeong, Jae-Gun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.201-204
    • /
    • 2011
  • ISO 13784-1 sandwich panel tests were conducted by FILK, KICT in Korea, SP in Sweden and CSIRO in Australia. Sandwich panels composed of steel sheets, EPS and glass wool supplied by FILK were tested. Mainly heat release rate was compared and equality of distribution also analyzed on the point of statistical view based on ISO.

  • PDF

The Accident Analysis Caused by Dust of Electrical Installation in Vulnerable Area (전기설비 취약지역에서의 분진에 의한 사고영향 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Jong-Min
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.345-348
    • /
    • 2008
  • In this paper, we investigated a dust pollution and spot survey of electrical installation in vulnerable area. From the survey results, we know that the dust was easily accumulated in cabinet panel because the cabinet panel cover was opened and the management of installation was not good. Although the dust pollution was not difference, the possibility of accident become increased by dust in salt area. Thus, it is necessary to variation of cabinet panel shape to prevention of electrical disaster in dust occurrence and another protection devices.

  • PDF

A Study on the Discharge Characteristics and Formation of MgO Protection Layer for PDP by Reactive Sputtering (반응성 스파트링에 의한 PDP용 MgO 보호층 형성과 그 방전특성에 관한 연구)

  • 하홍주;이우근;남상옥;박영찬;조정수;박정후
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.357-360
    • /
    • 1996
  • MgO protection layer in ac PDP(plasma display panel) prevents the dielectric layer from ion bombarding in discharge plasma. The MgO layer also has the additional important role in lowering the firing voltage due to a large secondary electron emission coefficient. Until now, the MgO protection layer is mainly prepared by E-beam evaporation. In this study, MgO protection layer is prepared on dielectric layer of ac PDP cell by reactive R.F magnetron sputtering with Mg target under various conditions of oxygen partial pressure. Discharge characteristics of PDP is also studied as a parameter of MgO preparation conditions. The sputtered MgO shows the better discharge characteristics compared with MgO deposited by E-beam evaporator.

  • PDF

Effects of Intellectual Property Rights Protection on Services Export Diversification in Developing Countries

  • SENA KIMM GNANGNON
    • KDI Journal of Economic Policy
    • /
    • v.46 no.1
    • /
    • pp.53-89
    • /
    • 2024
  • The effects of the betterment of enforced intellectual property rights (IPRs) provisions on services export diversification are investigated. The analysis used an unbalanced panel dataset of 76 developing countries over the period of 1970-2014. The empirical analysis is based on the feasible generalized least squares estimator. It suggests that the implementation of weaker IPR protection fosters services export diversification in less developed countries (i.e., those whose real per capita incomes are less than US$US$ 1458.60), including those with a low level of export product upgrading. Conversely, in relatively advanced developing countries (countries whose real per capita income exceeds US$ 3356.80), including those with high levels of export product upgrading, the implementation of stronger IPR laws induces greater services export diversification. Finally, the analysis revealed the existence of a non-linear relationship between IPR protection and services export diversification. The implementation of stronger intellectual property laws spurs services export diversification in countries with high degree of IPR protection, especially when IPR protection exceeds a certain level, recorded here as having a score of 1.197. In contrast, in countries with weaker IPR protection, in particular those with IPR protection levels that score less than 0.915, it is rather the implementation of weaker intellectual property laws that promotes services export diversification.

Understanding and Attitude to Sustainable Development of College Students for a Nuclear Power Plant Construction in Education for Sustainable Development through Panel Discussion (패널토론을 적용한 지속가능발전교육에서 대학생의 원자력발전소 건립에 대한 지속가능발전 인식과 태도)

  • MOON, Sungchae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1236-1251
    • /
    • 2015
  • This study examined understanding and attitude of sustainable development(SD) of 38 college students in a nuclear power plant construction after education for sustainable development(ESD) through panel discussion. The results were as follows: First, after lesson 66% of students were expected that SD is possible if scientific technology is developed and a frugal life for the protection of environment is carried out. However, the remaining students regarded SD as an ideal concept, because they thought it is not possible to pursue environmental sustainability and socio-economic development simultaneously. Second, students' opinions in the evaluation of constructing a nuclear power plant in three aspects(environment, society and economy) before and after panel discussion were changed as follows; 1) After panel discussion, the objectors increased to 21% in economic evaluation, while the supporters increased to 11% in environmental evaluation. 2) Students majoring in engineering or natural sciences changed their opinions to agree in environmental evaluation because they considered a nuclear power plant safe and eco-energy. However students majoring in social science/business or liberal arts/arts changed their opinions to disagree in economic evaluation because they considered a nuclear power plant as high-cost energy when assessing danger-accidents cost, public consensus cost, operation and maintenance cost, and waste disposal cost. 3) This change of decision-making in students majoring in social science/business or liberal arts/arts after panel discussion was statistically significant(p<0.05). Implications of panel discussion as a teaching and learning method in ESD are also discussed.

Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel (리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

Top gate ZnO-TFT driving AM-OLED fabricated on a plastic substrate

  • Hwang, Chi-Sun;Kopark, Sang-Hee;Byun, Chun-Won;Ryu, Min-Ki;Yang, Shin-Hyuk;Lee, Jeong-Ik;Chung, Sung-Mook;Kim, Gi-Heon;Kang, Seung-Youl;Chu, Hye-Yong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1466-1469
    • /
    • 2008
  • We have fabricated 2.5 inch QQCIF AM-OLED panel driven by ZnO-TFT on a plastic substrate for the first time. The number of photo mask for the whole panel process was 5 and the TFT structure was top gate with active protection layer as a first gate insulator. Optimizing the process for the substrate buffer layer, active layer, ZnO protection layer, and gate insulator was key factor to achieve the TFT performance enough to drive OLED. The ZnO TFT has mobility of $5.4\;cm^2/V.s$, turn on voltage of -6.8 V, sub-threshold swing of 0.39 V/decade, and on/off ratio of $1.7{\times}10^9$. Although whole process temperature is below $150^{\circ}C$ to be suitable for the plastic substrate, performance of ZnO TFT was comparable to that fabricated at higher temperature on the glass.

  • PDF