• Title/Summary/Keyword: protection of design

Search Result 2,368, Processing Time 0.03 seconds

Numerical analysis results of the cathodic protection for the underground steel pipe by anode installation method

  • Jeong, Jin-A;Choo, Yeon-Gil;Jin, Chung-Kuk;Park, Kyeong-Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1212-1216
    • /
    • 2014
  • This study aims to find out the best anode location for buried pipelines. Numerical simulation program known as CATPRO (Elsyca, Belgium) were used for confirming the best location of anodes and the effects of impressed current cathodic protection system. Applied conditions for numerical simulation were similar to on-site environmental conditions for optimal application of cathodic protection system. Used criterion of cathodic protection was NACE SP 0169, which describes that minimum requirement for cathodic protection is -850mV vs. CSE. Various layouts for anodes' installation were applied, which were distance between anodes, anode installation location, and applied current. The areas where cathodic protection potential was lower than -850mV vs. CSE was limited up to 50m from anode installation locations. It was founded numerical analysis obtain cost-effective and efficient cathodic protection methods before design and application the impressed cathodic protection system to on-site environment.

A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities (대규모 위락시설의 피난안전성능 평가에 관한 연구)

  • Park, Bong-Rae;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.165-173
    • /
    • 2009
  • As the Performance Based Fire Protection Design is legislated, studies on a fire and evacuation are actively in progress. The Performance Based Fire Protection Design should be developed toward enlarging the Life safety. In addition, the Performance Based Fire Protection Design shall not merely review the aspects of fire fighting but it shall also include regulations pertaining to evacuation stipulated in laws and regulations for buildings. This study performed an evacuation time prediction based on OO Night Club, one of the multiplex use facilities located in Gwang-ju Metropolitan City in order to suggest as a referential data for the Performance Based Fire Protection Design implementation. To do this, I investigated domestic and foreign regulations and research papers related to evacuation and went to visit the actual site and collected materials. The collected data was then used as ones to input in Simulex, an evacuation program to measure evacuation time. The collected data was then used as data to input in Simulex, an evacuation program to measure evacuation time. Through this particular research and results, the study was able to suggest a few concerning areas.

Design and Management of Survivable Network: Concepts and Trends

  • Song, Myeong-Kyu
    • International Journal of Contents
    • /
    • v.5 no.2
    • /
    • pp.43-52
    • /
    • 2009
  • The article first presents a broad overview of the design and management for survivable network. We review the concept of network survivability, various protection and restoration schemes. Also we introduce design architectures of Quantitative model and a Survivable Ad hoc and Mesh Network Architecture. In the other side of study like these(traditional engineering approach), there is the concept of the survivable network systems based on an immune approach. There is one sample of the dynamic multi-routing algorithms in this paper.

The Analysis of Registration of Design Rights in Korean Apparel Industry -Design Rights Registered in Apparel (Classification B1)-

  • Kim, Yong-Ju
    • Proceedings of the Korea Society of Costume Conference
    • /
    • 2003.10a
    • /
    • pp.75-75
    • /
    • 2003
  • The distinctive design of apparel product is the crucial factor that provides the powerful competitive advantage and customer satisfaction. However, knock-offs or copycats easily copy the design of apparel product and its problem tends to be assented in real world. Design right is one of intellectual property rights that would be produced by intellectual activity and the appropriate means to establish the exclusive rights to the design should be established. Legal protection to the design right is the system that can prelude copycats from eroding an exclusive position in the market place. The present study was to analyze the trend of registration of design rights in apparel products and to point out problems of current protection law to design.

  • PDF

A Trend Analysis and Technology Application of Defense Technology Protection (방위산업 기술보호 동향분석 및 기법적용)

  • Lee, Hyo Keun;Lee, Woon Soon;Oh, Yoo Jin;Park, ShinSuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.579-586
    • /
    • 2017
  • The defense industry has become a global industry, and military technology is actively being traded between countries to increase their military capabilities. The Republic of Korea has been ranked one of the top 10 countries for exports of military technology. To maintain competitive advantages in the global defense industry, it is essential to protect key technologies employed by exported weapon systems. Various techniques have been developed for protection of confidential technologies in weapon systems, and the U.S. DoD has been leading the development of the protection techniques. This paper reviews current anti-tampering techniques that prevent leakage of key technology from weapon exportation or pillage. Based on the protection techniques employed by the U.S. DoD Anti-Tamper Executive Agent, this paper suggests novel design methods for protection of confidential technologies. The proposed design methods were tested on an actual weapon system.

Study on Propriety Evaluation for Protection of Rock Revetment (석축호안 보호공의 적정성 평가에 대한 연구)

  • Park, Moo-Jong;Choi, Sung-Wook;Baek, Chun-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.111-117
    • /
    • 2008
  • Recent climate changes have increased flood damage on bank and revetment. However design standard for revetment that is the one of the most important facility for flood protection is not enough in Korea. In this study, destruction of rock revetment in Guryecity caused by the flood on Aug 2007 was inquired by analysis using 2D hydraulic simulation model SMS and the propriety of established plan for protection of rock revetment was evaluated. For this purpose, the ranges of protection facility for revetment was calculated by two methods. The one is normal method to calculate range of pier scour protection facility, and the other is a method of the standard for river design in Korea. The results of both methods are compared to evaluate the established plan.

The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field (피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용)

  • Song, Gil-Mok;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

SHIELD DESIGN OF CONCRETE WALL BETWEEN DECAY TANK ROOM AND PRIMARY PUMP ROOM IN TRIGA FACILITY

  • Khan, M J H;Rahman, M;Ahmed, F U;Bhuiyan, S I;Haque, A;Zulquarnain, A
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.190-193
    • /
    • 2007
  • The objective of this study is to recommend the radiation protection design parameters from the shielding point of view for concrete wall between the decay tank room and the primary pump room in TRIGA Mark-II Research Reactor Facility. The shield design for this concrete wall has been performed with the help of Point-kernel Shielding Code Micro-Shield 5.05 and this design was also validated based on the measured dose rate values with Radiation Survey Meter (G-M Counter) considering the ICRP-60 (1990) recommendations for occupational dose rate limit ($10{\mu}Sv/hr$). The recommended shield design parameters are: (i) thickness of 114.3 cm Ilmenite-Magnetite Concrete (IMC) or 129.54 cm Ordinary Reinforced Concrete (ORC) for concrete wall A (ii) thickness of 66.04 cm Ilmenite-Magnetite Concrete (IMC) or 78.74 cm Ordinary Reinforced Concrete (ORC) for concrete wall B and (iii) door thickness of 3.175 cm Mild Steel (MS) on the entrance of decay tank room. In shielding efficiency analysis, the use of I-M concrete in the design of this concrete wall shows that it reduced the dose rate by a factor of at least 3.52 times approximately compared to ordinary reinforced concrete.

Optimizing the Novel Formulation of Liposome-Polycation-DNA Complexes (LPD) by Central Composite Design

  • Sun, Xun;Zhang, Zhirong
    • Archives of Pharmacal Research
    • /
    • v.27 no.7
    • /
    • pp.797-805
    • /
    • 2004
  • LPD vectors are non-viral vehicles for gene delivery comprised of polycation-condensed plasmid DNA and liposomes. Here, we described a novel anionic LPD formulation containing protamine-DNA complexes and pH sensitive liposomes composed of DOPE and cholesteryl hemisuccinate (Chems). Central composite design (CCD) was employed to optimize stable LPD formulation with small particle size. A three factor, five-level CCD design was used for the optimization procedure, with the weight ratio of protamine/DNA ($X_1$), the weight ratio of Chems/DNA ($X_2$) and the molar ratio of Chems/DOPE in the anionic liposomes ($X_3$) as the independent variables. LPD size ($Y_1$) and LPD protection efficiency against nuclease ($Y_2$) were response variables. Zeta potential determination was utilized to define the experimental design region. Based on experimental design, responses for the 15 formulations were obtained. Mathematical equations and response surface plots were used to relate the dependent and independent variables. The mathematical model predicted optimized $X_1-X_3$ levels that achieve the desired particle size and the protection efficiency against nuclease. According to these levels, an optimized LPD formulation was prepared, resulting in a particle size of 185.3 nm and protection efficiency of 80.22%.