• Title/Summary/Keyword: prosthetic replacement

Search Result 219, Processing Time 0.04 seconds

Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings (대동맥판막치환술 후 발생한 판막하 판누스(Pannus): 시간에 따른 변화 및 심초음파 소견)

  • Mi Yeon Park;Hyun Jung Koo;Hojin Ha;Joon-Won Kang;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1151-1163
    • /
    • 2020
  • Purpose This study aimed to evaluate changes of subprosthetic pannus on cardiac CT and determine its relationship to echocardiographic findings in patients with mechanical aortic valve replacement (AVR). Materials and Methods Between April 2011 and November 2017, 17 AVR patients (56.8 ± 8.9 years, 12% male) who showed pannus formation on CT and had undergone both follow-up CT and echocardiography were included. The mean interval from AVR to the date of pannus detection was 10.5 ± 7.1 years. In the initial and follow-up CT and echocardiography, the pannus extent and echocardiographic parameters were compared using paired t-tests. The relationship between the opening angle of the prosthetic valve and the pannus extent was evaluated using Pearson correlation analysis. Results The pannus extent was significantly increased on CT (p < 0.05). The peak velocity (3.9 ± 0.8 m/s vs. 4.2 ± 0.8 m/s, p = 0.03) and mean pressure gradient (36.4 ± 15.5 mm Hg vs. 42.1 ± 15.8 mm Hg, p = 0.03) were significantly increased. The mean opening angles of the mechanical aortic leaflets were slightly decreased, but there was no statistical significance (73.1 ± 8.3° vs. 69.4 ± 12.1°, p = 0.12). The opening angle of the prosthetic leaflets was inversely correlated with the pannus extent (r = -0.57, p < 0.001). Conclusion The pannus extent increases over time, increasing transvalvular peak velocity and the pressure gradient. CT can be used to evaluate the pannus extent associated with hemodynamic changes that need to be managed by surgical intervention.

Homograft Aortic Root Replacement (동종이식편을 이용한 대동맥 근부 치환술)

  • Kim Jae Hyun;Oh Sam Sae;Lee Chang-Ha;Baek Man Jong;Kim Chong Whan;Na Chan-Young
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.197-203
    • /
    • 2005
  • Homograft aortic valve replacement (AVR) has many advantages such as excellent hemodynamic performance, faster left ventricular hypertrophy regression, resistance to infection and excellent freedom of thromboembolism. To find out the results of homograft AVR, we reviewed our surgical experiences. Material and Method: Eighteen patients (male female=16 : 2, mean age=39.3$\pm$16.2 years, range: 14$\~$68 years) who underwent homo-graft aortic valve replacement between May 1995 and May 2004 were reviewed. The number of homografts was 20 (17 aortic and 3 pulmonic homografts) including two re-operations. Ten patients had a history of previous aortic valve surgery. Indications for the use of a homograft were native valve endocarditis (n=7), prosthetic valve endocarditis (n=5), or Behcet's disease (n=8). The homograft had been implanted predominantly as a full root except in one patient in the subcoronary position. Result: Mean follow-up was 41.3 $\pm$ 26.2 months. There was one operative mortality. Postoperative complications included postoperative bleeding in 3 patients, and wound infection in 1. There was no late death. Three patients underwent redo-AVR. The etiology of the three reoperated patients was Behcet's disease (p=0.025). Freedom from reoperation was $87.5\pm8.3\%$, $78.8\pm11.2\%$ at 1, 5 years respectively, In patients with infective endocarditis, there was no recurrence of endocarditis. There was no thromboembolic complication. Conclusion: Although longer term follow-up with larger numbers of patients is necessary, the operative and mid-term results for homograft AVR was good when we took into account the operative risks of Behcet's disease or infective endocarditis. Behest's disease was a risk factor for reoperation after the homograft AVR. We think homograft AVR is the procedure of choice, particularly in patients with infective endocarditis.

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Twenty-year Experience of Mitral Valve Replacement with the St. Jude Medical Mechanical Valve Prosthesis (St. Jude 기계 판막을 이용한 승모판막 치환술의 20년 장기성적)

  • Seo Yeon-Ho;Kim Kong-Soo;Jo Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.527-533
    • /
    • 2006
  • Background: A retrospective study was conducted to analyze the results of St. Jude Medical mitral valve replacement at the Chonbuk National University Hospital since the initial implant in May 1984. Material and Method: Between May of 1984 and December of 1996, 95 patients underwent MVR with the St. Jude Medical mechanical valve prosthesis at Department of Medical Science of Chonbuk National University Hospital and follow-up ended in May of 2004. Result: Age ranged from 19 to 69 years. Follow-up (mean${\pm}$standard deviation) averaged $10.6{\pm}4.2\;year$. Thirty-day operative mortality was 4.2% (4/95). Nine late deaths have occurred and actuarial survival was $90.5{\pm}3.0%,\;87.9{\pm}3.4%\;and\;83.2{\pm}4.6%$ at 5, 10 and 20 years, respectively. Probability of freedom from valve-rotated death was $95.5{\pm}2.1%,\;94.3{\pm}2.4%\;and\;91.0{\pm}3.9%$ at 5, 10 and 20 years, respectively. Seven patients have sustained thromboembolic events (1,05%/patient-year). Fifteen patients had anticoagulation related hemorrhage (3.56%/patient-year). There was no structural valve deterioration. Probability of freedom from all complications was $82.0{\pm}3.9%,\;71.3{\pm}4.8%\;and\;42.4{\pm}10.5%$ at 5, 10 and 20 years, respectively. Conclusion: We confirm the effective and excellent durability of the St. Jude Medical prosthesis in the mitral position with a low event rate at long-term follow-up. It also demonstrates the commonly encountered practical difficulty of adjusting the anti-coagulation protocol in patients with prosthetic mitral valves.

Functional and Radiological Results of Intermediate-term Follow Up in $MUTARS^{(R)}$ Tumor Endoprostheses ($MUTARS^{(R)}$ 종양 대치물을 이용한 사지 구제술의 기능적 및 방사선학적 중기 추시 결과)

  • Kang, Dong-Joon;Kim, Jeung-Il;Oh, Jong-Seok;Moon, Tae-Yong;Lee, In-Sook
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.17 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • Purpose: This study was designed to verify intermediate-term functional and radiological results of limb salvage operation using endoprosthetic replacement system ($MUTARS^{(R)}$) used in patients with a malignant bone tumor. Materials and Methods: Thirty one cases which used $MUTARS^{(R)}$ tumor prosthesis were reviewed. The mean age of the patients was 49.2 years and the mean follow up was 39.8 months. We retrospectively reviewed complications, and evaluated functionally and radiologically by Enneking functional score, ISOLS radiological implants evaluation system at last follow-up. Results: 3 patients had died of disease, distant metastasis was seen in 4 patients and local recurrence was seen in 1 patients. Complications were developed in 12 patients. (infection 6, leg length discrepancy 2, aseptic loosening 2, periprosthetic femoral fracture 1, screw loosening 1) Mean value of total functional scores were 81.2% in proximal femur, 77.4% in distal femur, 78.1% in proximal tibia, and 80.2% in proximal humerus. The overall radiological result was relatively satisfactory. Conclusion: Our results suggest limb salvage with the $MUTARS^{(R)}$ endoprosthesis is successful with good functional and radiological results. But we should be careful with complications such as infection.

Mitral Valve Repair for Mitral Regurgitation (승모판막폐쇄부전에 대한 승모판막재건술)

  • 최세영;유영선;박기성;최대융;박창권;이광숙
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.221-225
    • /
    • 1998
  • From February 1996 to May 1997, 18 patients underwent mitral valve repair for mitral regurgitation. There were 9 male and 9 female patients aged from 19 to 68 years(mean, 53). Thirteen patients were in New York Heart Association(NYHA) class III and IV. The cause of mitral regurgitation was degenerative in 12 patients, rheumatic in 5 patients and infective in 1 patient. Fifteen patients were in Carpentier's functional classification II, 2 patients in Carpentier's class III and 1 patient in Carpentier's class I. Surgical procedures included prosthetic ring annuloplasty(16 cases), rectangular resection of posterior leaflet(15 cases), chordal shortening(5 cases), triangular resection of anterior leaflet(2 cases), commissurotomy(2 cases), partial transposition of posterior leaflet(1 case). These procedures were combined in most patients. There was no operative death. These patients have been followed from 1 to 15 months, mean of 6.7 months. There was one late death resulted from low cardiac output following mitral valve replacement. The function of the repaired valve in other 17 patients has remained satisfactory during the observed interval. We consider that mitral valve repair is highly satisfactory in patients with mitral regurgitation.

  • PDF

Analysis of Factors Affecting Nontherapeutic INRs in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 치료범위를 벗어난 INR 원인분석)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.746-760
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objectives of this study were to determine the causes of nontherapeutic INRs, and to identify the factors associated with nonadherences to warfarin therapy in Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997b to September, 2000. The data on 868 patients (5,304 visits) who were at least 6 months post-valve replacement were included. All possible causes of nontherapeutic INRs were documented for each patient visit. The association of covariates to noncompliance was investigated by univariate analysis. Result: The reasons for nontherapeutic INRs were identified as follows: inadequate dosage adjustment $(21\%)$, nonadherences to dosing regimen $(13\%)$, drug/herbal interactions $(12\%)$, changes in diet $(7\%)$, and indeterminate cause $(42\%)$. Younger age, shorter duration of ACS and longer duration of warfarin therapy were associated with nonadherence. Conclusion: In this study, nonadherence and interactions between diet and medications were found to be important factors influencing nontherapeutic INRs. Longer duration of enrollment in the ACS affected the adherence to warfarin therapy Positively whereas younger age and longer duration of warfarin therapy affected negatively.

Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions (상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구)

  • Park, Kyung-Ah;Jeong, Cheol-Woong;Ryoo, Gyeong-Ho;Park, Kwang-Bum;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.

The Morphological Changes of Cryopreserved Rat Trachea After Heterotopic Transplantation (쥐의 초냉동기관 이소 이식 후 형태학적 변화)

  • 성숙환;서정욱;박종호;김경환
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1182-1190
    • /
    • 1996
  • The best treatment of congenital or acquired tracheal stenosis is resection and end to end anastomosis. Various prosthetic material and tissue graft replacement can be considered when the stenotic segment is too long, but their uses are still limited due to many serious complications. The present study examined the effect of immunosuppression and cryopreserved allograft trachea after intraperitoneal omental implantation for evaluation of the possibility of tracheal transplantation. Thirty tracheal segments were harvested from fifteen donor Wistar rats. Among them eighteen segments were implanted immediately(group I, II, III) and twelve segments were used for cryopreservation(group IV, V). Heterotopical intraperitoneal implantation was performed in five groups of rats(n=6); Group I was Wistar syngeneic controls and received no immunosuppression. Group II and III were those of Sprague-Dawley recipients, the former receiving no immunosuppression and the latter receiving immunosuppression(Cyclosporin A 15mg/kg/day, Methylprednisolone 2mg/kg/day). Group IV and V were groups of Sprague-Dawley recipients, the former receiving immunosuppression and the latter receiving no Immunosuppression. After 28 days, rats were sacrificed and the tracheal segments were histologically evaluated. Epithelial thickness was significantly decreased in group II, IV. Epithelial regeneration score was also significantly decreased in II. All rats maintained well their round tracheal contour. In conclusion; I) trachea could be preserved for a long time with cryo method, 2) epithelium could regenerate fully with omentopexy in cryopreserved trachea, 3) immunosuppresion was not necessary with cryopreserved trachea.

  • PDF

Durability of Xenograft Cardiac Valves (이종조직 판막의 내구성)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.494-503
    • /
    • 1992
  • The durability of the xenograft cardiac substitute valves is of a great concern on the clinical grounds. Four groups of tc tal and consecutive patients to the end of study operated on between 1976 and 1984 were Group ISM, 291 patients of MVR, ISA, 65 patients of AVR, and ISMA, 107 patients of MVR+AVR with the standard Ionescu-Shiley bovine pericardial valve, and H, 163 patients of valve replacement with the Hancock porcine aortic vlave. Operative mortality was 5.2%[ISM], 10.8%[ISA], 7.5%[ISMA] and 6.1%[H]. Early survivors were followed up for a total of 1148.3 patient-years[pt-yrs] [ISM], 271.2 pt-yrs [ISA], 488.1 pt-yrs[ISMA] and 822.9 pt-yrs[H]. Linearized late mortality was 2.1% /pt-yr [ISM], 1.l%/pt-yr[ISA], 1.8%/pt-yr[ISMA] and 1.8% /pt-yr[H]. Thromboembolic complication was experienced at the linearized rate of 1.045% /pt-yr [ISM], 1.475%/pt-yr[ISA], 0.615%/pt-yr[ISMA] and 1.822%/pt-yr[H], and bleeding complication at the rate of 0.871% /pt-yr[ISM], 0.63% /pt-yr[ISA], 0.205% /pt-yr [ISMA] and 0.729%a /pt-yr[H], respectively. Prosthetic valve endocarditis occurred at the rate of 0.610% /pt-yr[ISM], 1.475% /pt-yr[ISA], 1.639% /pt-yr[ISMA] and 0.972% /pt-yr[H]. The linearized annual incidence of primary tissue failure was 1.655%/pt-yr[ISM], l. 475%/pt-yr[ISA], 1.639% /pt-yr[ISMA], 2.187% /pt-yr[H] and 1.785% /pt-yr[Group HM : MVR with Hancock valve]. The incidence of tissue failure was significantly high in the patients younger than 30 years of age compared with the older patients. The actuarial survival was 87.7$\pm$2.5% at 10 years[ISM], 94.3$\pm$3.2% at 11 years[ISA], 89.6$\pm$3.4% at 10 years[ISMA] and 81.3$\pm$6.6% at 12 years[HM], The freedom from thromboembolism was 93.2$\pm$2.0% at 10 years[ISM], 90.6$\pm$4.6% at 11 years[ISA], 95.8$\pm$2.6% at 10 years[ISMA] and 80.9$\pm$11.1% at 12 years[HM], And, the freedom from primary tissue failure was 84.2$\pm$3.8% and 28.1$\pm$23.0% at 9 and 10 years[ISM], 60.4$\pm$16.9% at 11 years[ISA], 62.3$\pm$12.7 at 10 years[ISMA] and 65.6$\pm$9.8% at 12 years[HM]. In conclusion, the standard Ionescu-Shiley and the Hancock bioprosthetic valves are excellent in their antithrombogenicity and long-term survival. However, the features of the structural failure with the prolonged follow-up beyond 10 years appear to be guarding, and the clinical indications of these bioprostheses seem to be quite limited.

  • PDF