• Title/Summary/Keyword: prosthetic replacement

Search Result 219, Processing Time 0.022 seconds

Treatment of Bone Tumors with a Custom-made Prosthetic Replacement (인공 관절 대치술로 치료한 골 종양)

  • Shin, Hyun-Kug;Suh, Jae-Sung;Ahn, Jong-Chul;Ihn, Joo-Chul
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.206-214
    • /
    • 1991
  • We treated three cases of bone tumors-giant cell tumor, chondroblastoma and malignant fibrous histiocy toma-with a custom-made prosthetic replacement. The patients were followed from 10 months to 18 months, postoperatively. The results of these study are as follows : 1. satisfactory anatomic restoration 2. early ambulation 3. good function 4. biomechanically sound reconstruction.

  • PDF

Prediction of the Prosthetic Valve size by use of Supraaortic Cineangiogram (Cineangiogram 을 이용한 대동맥판막의 수술전 인공판막 치수의 예)

  • Lee, Young-Thak;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.60-64
    • /
    • 1987
  • We compared between prosthetic aortic valve size and aortic annulus size in supravalvular aortic cineangiogram in 30` RAO view postoperatively. Retrospectively, supraaortic cineangiogram of 27 patients among the patients underwent aortic valve replacement only or double valve replacement from April, 1986 to January, 1987 was examined and measured the aortic annulus size. In comparing the two values, the cases within 1mm is 22, and the cases within 2mm is 25, correlation coefficient yield r = 0.92. In two cases, the difference between two values is within 3mm We concluded that to prevent the complication from mismatching the prosthetic aortic valve size to patient`s annulus size [e.g. left ventricular failure, hemolysis, limited exercise tolerance], prediction of the prosthetic valve size preoperatively by use of cineangiogram is useful.

  • PDF

Total Hip Replacement for Treatment of Chronic Coxofemoral Joint Dislocation in 7 Dogs

  • Yoon, Jang-Won;Heo, Su-Young;Jeong, Seong-Mok;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.36 no.4
    • /
    • pp.229-232
    • /
    • 2019
  • Total Hip Replacement in a patient with chronic coxofemoral joint dislocation is a challenging problem because chronic coxofemoral joint dislocation causes severe morphological changes. These challenging factors make surgery more difficult and increase the possibility of postoperative complications including cup implant dislocation and prosthetic joint luxation. All patients were diagnosed having at least 2 months of coxofemoral joint dislocation. On physical examination, crepitus was noted in the coxofemoral joint. Radiographs revealed hip joint dislocation with mild to severe degenerative changes. Total hip replacement was planned for all patients. Dorsal acetabular rim deficiency in 3 cases was augmented using a locking plate and polymethylmethacrylate bone cement. All cases have shown difficulty in prosthetic joint reduction. Pectineus and rectus femoris muscle origin were released in all cases. At 12 months follow up, all patients showed satisfactory ambulation. The issues on perioperative prosthetic joint reduction and luxation due to chronic coxofemoral joint luxation with muscle contracture and dorsal acetabular rim deficiency can be resolved by muscle releasing and dorsal acetabular rim augmentation.

The orthodontic treatment of congenitally abscent maxillary lateral incisors: Case Report (상악 측절치의 선척적 결손시 교정치료)

  • Ji, Dae-Gyeong;Im, Yong-Gyu;Lee, Dong-Ryeol
    • The Journal of the Korean dental association
    • /
    • v.37 no.12 s.367
    • /
    • pp.1012-1018
    • /
    • 1999
  • Whether congenitally abscent or lost as the of an accident or pathologic condition, missing lateral incisors present a problem. which complicates orthodontic treatment. The condition requires careful treatment planning and a consideration of the options and outcomes following either space closure or prosthetic replacement. Thos study prasents the clinical cases with maxillary lateral incisors missing. following optimal diagnosis and treatment planning , considerations in treatment in these cases.

  • PDF

Surgical Experience of Congenital Tricuspid Stenosis - A Report of Case - (선천성 삼첨판 협착증의 수술치험 1례)

  • Kim, Jhin-gook;Ahn, Hyuk;Oh, Byung-Hee
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.700-705
    • /
    • 1988
  • A case of congenital tricuspid stenosis in 24 year old male patient is presented. The lesion was successfully corrected with prosthetic valve replacement and closure of atrial and ventricular septal defects. Especially, this is the first reported case of successful large prosthetic valve replacement to a small annulus in tricuspid valve.

  • PDF

Reoperations for Prosthetic Valve Replacement (인공판막치환술후 재수술)

  • 유영선
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1090-1097
    • /
    • 1991
  • Between January 1981 and January 1991, 554 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 238 cases and mechanical valve 316 cases. Thirty-eight patients underwent 40 reoperations for repair or replacement, an average of 53.6 months after initial implantation. There were 21 women and 19 men, aged 12 to 60 years[mean 35.3]. A bioprosthetic valve was implanted in 31 cases and a mechanical valve in 9 cases for initial operation. Indications for reoperation were primary tissue failure in 23 cases[57.5%], endocarditis in 9[22.5%], periprosthetic leak in 4[10%]. and valve thrombosis in 4[10%]. Operations performed included 5 aortic valve replacements, 26 mitral valve replacement, 8 double valve replacements, and 1 thrombectomy. A mechanical valve was replaced in 33 cases[84.6%] and a bioprosthesis in 6[15.4Zo] for reoperation. A second reoperation was required in 2 patients. Surgical mortality was 10% . Among the 34 early survivors followed-up for an average of 19.8 months. there was 1 late death and 3 were lost to follow-up. Among the 30 late survivors being followed up, 28[93.3%] remained in New York Heart Association Class I or II and two in Class III [6.7%].

  • PDF

Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus (협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

Pediatic Valve Replacement (15세 이하 소아에서의 판막치환술)

  • 박재홍
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.984-988
    • /
    • 1994
  • Between 1981 and 1992, 22 children from 1 to 15 years of age have undergone cardiac valve replacements at National medical center. The patients were composed of 14 males and 8 females and 7 patients had congenital heart disease and 15 patients had rheumatic heart disease. Three of these 15 patients have had second valve replacement due to prosthetic valve failure[PVF]. Single valve replacement were 20[Aortic 3 cases, Mitral 17 cases] and double valve replacments were 2. The overall mortality was 22.7 %. Actuarial survival rate was 77.28 $\pm$ 8.92 % and Complication free rate was 67.68$\pm$15.56%. The pediatric valve replacements can now be performed at a low operative risk although various problems are still remained and the choice of valve is prosthetic valve mainly due to its durability at the present time.

  • PDF

Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case- (동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

Mitral Valve Replacement -Report of Five Cases- (승모판막 이식수술 -5예 보고-)

  • 송요준
    • Journal of Chest Surgery
    • /
    • v.7 no.2
    • /
    • pp.189-200
    • /
    • 1974
  • The mitral valve replacement with Beall prosthetic valve was performed on three patients, and double valve replacement. aortic and mitral valve, was performed in this department.1) The preoperative studies about the first case were compatible with mitral steno-insufficency.The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary hypass using hypothermic hemodilution technique. The total perfusion time was eighty minutes. Immediate postoperative course was smooth, but this patient was died of asphyxia due to tracheomalacia complicated after tracheostomy 3 months after operation. Autopsy on this patient revealed that no thrombus and no ball variance could be found, and endothelization on the valve cuff was satisfactory. 2) The preoperative studies on the second case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve under the cardiopulmonary bypass using hypothermic hemodilution technigue. The total perfusion time was 123 minutes. This patient was discharged in good condition and follow-up study after 16 months revealed the patient had enjoyed healthy life. 3) The preoperative studies about the third case were compatible with aortic insufficiency and mitral stenoinsufficiency. The diseased valves were replaced with type 2 sutureless Magovern aortic valve and the medium sized Beall mitral prosthesis under cardiopulmonary bypass using hypothermic hemodilution technIque and coronary artery perfusion. The total perfusion time was 155 minutes. This patient was discharged in good condition, but thromboembolism was developed 2 months after discharge. 4) The preoperative studies about the fourth case were compatible with mitral insufficiency. The diseased mitral valve was replaced with the medium sized Beall prosthetic valve. The total perfusion time was 132 minutes. The atrioventricular block developed just after operation but converted to normal sinus rhythmn on the third postperative day. The preoperative NYHA functional classification IV was converted to Class 1 or 11 at the time of discharge and this patient enjoyed healthy life. Attendum; The fifth case, nineteen years old male with mital insufficiency underwent Beall valve replacement and his course was uneventful 2 weeks after operation.

  • PDF