• 제목/요약/키워드: properties of modulus

검색결과 2,977건 처리시간 0.032초

레진강화형 글라스아이오노머의 2 축 굽힘강도 (BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS)

  • 이용근;임미경;구대회;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF

고온 신뢰성 시험에서 발생된 플렉서블 OLED의 휨 변형 (Warpage of Flexible OLED under High Temperature Reliability Test)

  • 이미경;서일웅;정훈선;이정훈;좌성훈
    • 마이크로전자및패키징학회지
    • /
    • 제23권1호
    • /
    • pp.17-22
    • /
    • 2016
  • 플렉서블 OLED는 매우 다양한 유기(organic) 및 무기 물질로 이루어져 있으며, 각 층을 증착하는 과정에 의하여 고온에 의한 휨(warpage)이 발생한다. 휨으로 인하여 발생한 굽힘 변형은 후속 공정에 많은 영향을 미치며, 궁극적으로 생산 수율 및 신뢰성을 저하시킨다. 본 연구에서는 플렉서블 OLED 소자의 고온 환경신뢰성 시험 및 공정 단계에서 발생하는 휨 변형을 수치해석을 이용하여 예측하였으며 실험 결과와 비교하였다. 이를 통하여 휨에 가장 큰 영향을 미치는 재료를 파악하고, 궁극적으로 휨을 최소화 함으로써 플렉서블 OLED의 신뢰성을 향상시키고자 하였다. 휨의 측정 및 수치해석 결과, 편광 필름과 베리어 필름이 휨에 많은 영향을 줌을 알 수 있었으며, OCA가 휨에 미치는 영향은 미미하였다. 플렉서블 OLED의 휨에 가장 큰 영향을 주는 소재는 plastic cover이였으며, 휨을 최소화하기 위한 plastic cover 소재의 최적 물성을 실험계획법으로 계산한 결과, 탄성 계수는 4.2 GPa, 열팽창계수는 $20ppm/^{\circ}C$ 일 경우 플렉서블 OLED의 휨은 1 mm 이하가 됨을 알 수 있었다.

가소화 전분필름의 강도 및 열적 성질에 미치는 나노셀룰로오스 및 아민화전분의 첨가영향 (Effect of Nanocellulose and Aminated Starch on Tensile and Thermal Properties of Plasticized Starch Film)

  • 김보연;한송이;이선영;김영균;김남훈;이승환
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권4호
    • /
    • pp.376-384
    • /
    • 2014
  • 본 연구는 가소화 전분필름의 열적 및 강도적 성질에 미치는 두 종류의 나노셀룰로오스, 즉 마이크로피브릴 셀룰로오스(MFC)와 셀룰로오스 나노크리스탈(CNC) 및 아민화전분의 첨가영향을 조사하였다. 글리세롤(23 wt%)을 전분의 가소제로 사용하였으며, 나노셀룰로오스를 각각 1, 5, 10, 30 중량부(phr)를 첨가하여 나노필름을 제조하였다. 나노셀룰로오스의 첨가량이 증가함에 따라 인장강도 및 탄성율은 비례적으로 증가하였으나 신장율은 저하하였다. 또한, MFC 강화필름의 강도적 성질이 CNC 강화필름보다 큰 값을 나타냈다. 제지용 사이즈제로 사용하는 아민화전분의 소량 첨가는 강도적 성질의 향상에 양호한 영향을 미쳤다. MFC 강화 전분나노필름의 TGA에 의한 열적 안정성은 MFC (30 phr)의 첨가에 의하여 향상되었으며, 아민화전분 첨가 나노필름의 경우에도 MFC를 첨가함으로써 향상되었다.

개에서 Poly-L-lactic-acid 이식물의 생분해성과 생체적합성에 관한 연구 (Study of Bio-absorbability and Bio-compatibility of Poly-L-lactic-acid Implant in Dogs)

  • 박보영;김영기;박종윤;박종만;고필옥;장홍희;이희천;이효종;연성찬
    • 한국임상수의학회지
    • /
    • 제24권2호
    • /
    • pp.182-191
    • /
    • 2007
  • Bioabsorbable devices have been utilized and experimented in many aspects of orthopaedic surgery. Depending upon their constituent polymers, these materials can be tailored to provide sufficient rigidity to allow bone healing, retain mechanical strength for certain period of time, and then eventually begin to undergo degradation. The objective of this study was to estimate extent in which Poly-L-latic acid (PLLA) implants had bioabsorbability and biocompatibility with bone and soft tissue in dogs and also to develop bioabsorbable, biocompatible materials with the appropriate strength and degradation characteristics to allow for regular clinical use for treating orthopedic problems in humans as well as animals. Eighteen dogs were used as experimental animals and were inserted two types of PLLA implants. PLLA rods were inserted into subcutaneous tissue of back or the abdomen wall. And the rods were tested for material properties including viscosity, molecular weight, melting point, melting temperature, crystallinity, flexural strength, and flexural modulus over time. PLLA screws were inserted through cortical bone into bone marrow in the femur of the dogs and stainless steel screw was inserted in the same femur. Radiographs were taken after surgery to observe locations of screw. Histological variations including cortical bone response, muscular response, bone marrow response were analyzed over the time for 62weeks. The physical properties of PLLA rods had delicate balances between mechanical, thermal and viscoelastic factors. PLLA screws did not induce any harmful effects and clinical complications on bone and soft tissue for degradation period. These results suggest that PLLA implants could be suitable for clinical use.

충격시험에 따른 배의 허용낙하높이 추정 (Estimation of Allowable Drop Height for Oriental Pears by Impact Tests)

  • 김만수;정현모;서륜;박일규;황용수
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.461-468
    • /
    • 2001
  • Impact between fruits and other materials is a major cause of product damage in harvesting and handling systems. The oriental pears are more susceptible to bruising than other fruits such as European pears and apples, and are required more careful handling. The interest in the handling of the pears for the processing systems has raised the question of the allowable drop height to which pears can be dropped without causing objectionable damage. Drop tests on pears were conducted using an impact device developed by authors to estimate the allowable drop height without bruising. The impact device was constructed to hold in a selected orientation and to release a fruit by vacuum for dropping on to a force transducer. The drop height was adjustable for zero to 60 cm to achieve the desired distance between the bottom of the fruits and the top of the impact force transducer. The transducer was secured to 150 kg$\sub$f/ concrete block. The transducer signal was sampled every 0.17 ms with a strain gage measurement board in the micro computer where it was digitaly stored for later analysis. The selected sample fruit was Niitaka cultivar of pears which is one of the most promising fruit for export in Korea. The pears were harvested during the 1998 harvest season from an orchard in Daejeon. The sample fruit was selected from two groups which were stored for 3 months and 5 months respectively by the method of current commercial practice. The pears were allowed to stabilize at environmental condition(18$^{\circ}C$, 65% rh) of the experimental room. One hundred fifty six pears were tested from the heights of 5, 7.5. 10 and 12.5 cm while measurement were made of impact peak force, contact time, time to peak force, dwell time, pear diameter and mass. The bioyield strength and modulus of elasticity were measured using UTM immediately after each drop test. The allowable drop height was estimated on the base of bioyield strength of the pears in two ways. One was assumed the peak force during impact test increasing linearly with time, and the other was based on the actual drop test results. The computer program was developed for measuring the impact characteristics of the pears and analyzing the data obtained in the study. The peak force increased while contact times decreased with increasing drop height and contact times of the sample from the hard tissue group. The allowable drop height increased with increasing bioyield strength and contact times, and also varied with Poisson\`s ratio, mass and equilibrium radius of the pears. The allowable drop height calculated by a theoretical method was in the range from 1 to 4 cm, meanwhile, the estimated drop height considering the result of the impact test was in the range from 1 to 6 cm. Since the physical properties of fruits affected significantly the allowable drop height, the physical properties of the fruits should be considered when estimating the allowable drop height.

  • PDF

고성능 탄소섬유 제조를 위한 폴리아크릴로니트릴 기반 공중합 고분자 합성 및 전구체 섬유 방사 (Polyacrylonitrile based Copolymer Synthesis and Precursor Fiber Spinning for Manufacturing High-performance Carbon Fiber)

  • 주혜진;한민정;송경현;전창범;정화경;김민정;채한기
    • Composites Research
    • /
    • 제35권2호
    • /
    • pp.115-119
    • /
    • 2022
  • 탄소섬유의 성능은 탄소 섬유 강화 플라스틱(CFRP)과 같은 고품질 고분자 복합재료에 매우 중요하다. 이를 위해 탄소섬유 물성에 큰 영향을 주는 전구체 섬유의 기계적, 물리적, 구조적 특성을 개선할 수 있는 최적화된 방사공정과 이를 위한 적합한 전구체 공중합 고분자를 사용하는 것은 필수적이다. 본 연구에서는 메타크릴산(MAA)의 함량과 주입시간, 2,2'-아조비스(2-메틸프로피오니트릴) (AIBN)의 농도를 합성공정 변수로 설정하였으며, 용액 중합법(solution polymerization)에 의해 Poly(AN-co-MAA)가 합성되었다. 305,138 g/mol의 분자량과 4.2%의 MAA 비율을 가지는 Poly(AN-co-MAA)를 N,N-디메틸포름아미드(DMF)에 16.0 wt% 농도로 용해시킨 후 기격습식방사법(dry-jet-wet spinning)으로 전구체 섬유를 제조하였다. 섬유의 인장강도는 ~1.06 GPa, 인장탄성률은 ~22.01 GPa였으며, 섬유에서의 공극 및 구조적 결함은 관찰되지 않았다.

폐플라스틱 재활용 폴리머콘크리트의 강도와 응력-변형률 특성 (Properties of Strength and Stress-Strain of Recycled-Plastic Polymer Concrete)

  • 조병완;구자갑;박승국
    • 콘크리트학회논문집
    • /
    • 제17권3호
    • /
    • pp.329-334
    • /
    • 2005
  • 폴리머콘크리트는 시멘트 콘크리트에 비해 강도와 내구적 성능 등 여러면에 있어 우수하여 건설현장에서의 벽체용 패널, 통신용 맨흘, 기계설비의 기초, 지하연결박스 등 다양한 용도로 개발되고 사용되어지고 있다. 그러나 폴리머콘크리트는 그 결합재로 쓰이고 있는 수지의 비용이 높아 경제적인 면에서 불리하여 기존 수지를 대체할 수 있는 결합재에 관한 연구가 필요하다. 여기서, PET를 재활용한 폴리머콘크리트는 산업폐기물을 재활용한 것이므로 경제적인 건설 소재가 될 수 있으며, 친환경적인 효과를 가져올 수 있기 때문에 현재 연구가 활발하게 이루어지고, 사용 영역이 확대 될 것으로 전망된다. 하지만 아직까지 PET재활용 폴리머콘크리트의 응력-변형률 거동에 관해서는 기초적인 연구상태에 있다. 따라서, 본 연구에서는 폐 PET를 합성한 불포화 폴리에스터 수지를 폴리머콘크리트의 결합재로 이용하여 콘크리트를 제조하였으며, 수지량, 골재의 최대치수, 양생방법에 변화를 주었다. 그리고 변위제어가 가능한 M.T.S 장비를 사용하여 응력-변형률 곡선을 관찰하였다. 그 결과 PET 재활용 폴리머콘크리트의 압축강도는 수지의 함량, 굵은골재의 크기변화, 양생방법에 모두 영향을 받는 것으로 나타났다. 탄성계수의 변화는 수지의 함량이 크게 좌우하였으며, 굵은골재의 최대치수와 양생방법에서 크게 영향을 받지 않았다. 최대응력에서의 변형률은 수지의 함량과 굵은골재의 최대치수에 영향을 많이 받는 것으로 나타났다.

60MPa급 고강도 콘크리트의 굵은골재 종류와 고온상태에 따른 변형특성 평가 (Evaluation on Strain Properties of 60 MPa Class High Strength Concrete according to the Coarse Aggregate Type and Elevated Temperature Condition)

  • 윤민호;최경철;이태규;김규용
    • 콘크리트학회논문집
    • /
    • 제26권3호
    • /
    • pp.247-254
    • /
    • 2014
  • 화재시 콘크리트 구조물은 구성재료의 상이한 열적특성으로 인해 강도가 저하하고 동시에 수직부재는 수평부재의 팽창에 의한 모멘트하중을 받아 전단파괴가 발생한다. 따라서 여러가지 화재곡선을 사용한 콘크리트 구조물의 화재시 거동에 대한 연구가 많이 이루어졌지만 주로 온도상승구간에서 발생하는 폭렬특성과 열팽창변형에 관한 연구가 대부분이다. 하지만 고온이 유지될 경우 발생할 수 있는 크리프변형은 화재시 구조물의 안정성에 큰 영향을 미치지만 상대적으로 연구가 미진한 상태이다. 또한 이러한 고온을 받는 콘크리트의 안정성에는 체적의 대부분을 차지하는 굵은골재의 열적특성이 큰 영향을 미치기 때문에 이 연구에서는 화강암계, clay계, clay-ash계 세 종류의 굵은골재를 사용한 콘크리트의 고온 역학적 특성을 평가했다. 그 결과 굵은골재의 성인으로 인한 내부공극 때문에 경량골재를 사용한 콘크리트가 일반골재를 사용한 콘크리트보다 높은 고온강도 및 탄성계수를 나타냈고 열팽창변형과 전체변형의 경우 더 낮은 변형률을 나타내어 온도상승구간에서의 구조적 안정성 측면에서 유리한 것으로 판단되었다. 그러나 고온크리프의 경우 내부공극으로 인해 더 큰 수축량이 발생하기 때문에 내화성능설계시에 이에 대한 추가적인 고려가 필요할 것으로 판단되었다.

대경권 셰일 골재의 풍화특성 및 셰일 골재 사용량에 따른 콘크리트의 동결융해 특성 (Weathering Properties of Shale Aggregate in Daegu-Kyeongbuk region and Freezing-Thawing Characteristics of Concrete in response to Usage of Shale Aggregate)

  • 이승한;정용욱;여인동;최종오
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.4033-4038
    • /
    • 2013
  • 건설공사 현장에서 발생하는 버럭 중 퇴적암은 대부분 야적, 매립 등으로 폐기하고 있어 공사비의 증대 및 시공 비효율화의 원인이 되고 있다. 이 중 일부 사암의 경우 선별하여 골재로 활용하기도 하지만, 셰일은 대부분 산업폐기물로 매립하고 있는 실정이다. 이에 본 연구에서는 대경권의 골재수급 안정화 및 콘크리트용 대체골재 자원 개발의 일환으로 대경권에 널리 분포하고 있는 셰일 골재의 풍화특성을 평가하였으며, 셰일 골재의 치환율 변화에 따른 콘크리트의 동결융해 특성을 평가하였다. 실험에 사용된 셰일은 대구시 터파기 공사현장에서 반출되는 레드셰일과 블랙셰일을 선정하였으며, 콘크리트용 굵은 골재로 널리 사용되는 안산암과 변성퇴적암의 일종인 혼펠스와 비교함으로써 셰일의 콘크리트용 골재 활용성을 검토하였다. 실험결과, 안산암과 혼펠스의 경우 시간 경과에 따른 열화현상이 발견되지 않았으나, 블랙셰일은 모암의 일부가 박리되는 현상이 발견되었다. 레드셰일은 직접 폭로 1.5개월 경과 후 층리의 방향에 따라 균열이 발생하기 시작하였으며, 약 4개월 경과 후 잘게 부수어지는 현상이 나타났다. 셰일 골재 치환율에 따른 제조한 콘크리트의 300 cycle 동결융해 반복 후 상대동탄성계수는 Plain에서 97%, Hornfels는 95%로 나타났으며, RS_100의 경우 반복횟수 210 Cycle에서 57%, BS_100의 경우 반복횟수 240 Cycle에서 상대동탄성계수가 54%로 나타나 셰일 골재를 사용한 콘크리트의 동결융해 저항성이 반복횟수 증가에 따라 급격히 감소하는 것으로 나타났다.

The Formation of Extragraft Bone Bridging after Anterior Cervical Discectomy and Fusion : A Finite Element Analysis

  • Kwon, Shin Won;Kim, Chi Heon;Chung, Chun Kee;Park, Tae Hyun;Woo, Su Heon;Lee, Sung-Jae;Yang, Seung Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.611-619
    • /
    • 2017
  • Objective : In addition to bone bridging inside a cage or graft (intragraft bone bridging, InGBB), extragraft bone bridging (ExGBB) is commonly observed after anterior cervical discectomy and fusion (ACDF) with a stand-alone cage. However, solid bony fusion without the formation of ExGBB might be a desirable condition. We hypothesized that an insufficient contact area for InGBB might be a causative factor for ExGBB. The objective was to determine the minimal area of InGBB by finite element analysis. Methods : A validated 3-dimensional, nonlinear ligamentous cervical segment (C3-7) finite element model was used. This study simulated a single-level ACDF at C5-6 with a cylindroid interbody graft. The variables were the properties of the incorporated interbody graft (cancellous bone [Young's modulus of 100 or 300 MPa] to cortical bone [10000 MPa]) and the contact area between the vertebra and interbody graft (Graft-area, from 10 to $200mm^2$). Interspinous motion between the flexion and extension models of less than 2 mm was considered solid fusion. Results : The minimal Graft-areas for solid fusion were $190mm^2$, $140mm^2$, and $100mm^2$ with graft properties of 100, 300, and 10000 MPa, respectively. The minimal Graft-areas were generally unobtainable with only the formation of InGBB after the use of a commercial stand-alone cage. Conclusion : ExGBB may be formed to compensate for insufficient InGBB. Although various factors may be involved, solid fusion with less formation of ExGBB may be achieved with refinements in biomaterials, such as the use of osteoinductive cage materials; changes in cage design, such as increasing the area of polyetheretherketone or the inside cage area for bone grafts; or surgical techniques, such as the use of plate/screw systems.