• 제목/요약/키워드: progressive area

검색결과 276건 처리시간 0.025초

중복비트 제거를 이용한 SPIHT알고리즘의 개선에 관한 연구 (A study on improvement of SPIHT algorithm using redundancy bit removing)

  • 설경호;이원효;고기영;김태형;김두영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.1920-1923
    • /
    • 2003
  • This paper presents compression rate improvement for SPIHT algorithm though redundancy bit removing. Proposed SPIHT algorithm uses a method to select of optimized threshold from feature of wavelet transform coefficients and removes sign bit if coefficient of LL area. Experimental results show that the proposed algorithm achieves more improvement bit rate and more fast progressive transmission with low bit rate.

  • PDF

Numerical Models of Water Wave with Parabolic and Hyperbolic Forms

  • Lee, Jong-Kyu;Lee, Chang-Hae
    • Korean Journal of Hydrosciences
    • /
    • 제2권
    • /
    • pp.25-37
    • /
    • 1991
  • The numerical models of the parabolic equation, applicable only to the progressive wave, and hyperblic equation, which may consider even the reflected wave, were developed and applied to the area of the submerged circular shoal and then results obtained from both models were compared with experimental measurements and each other. The hyperbolic model was further applied to both the detaced breakwater and the breakwater with a gap. The numerical results were plotted and compated with the existing data. Numerical solutions were obtained with the finite difference method.

  • PDF

신선가공한 고탄소 강선의 연성에 영향을 주는 미세조직 인자 (Effect of Microstructural Factors on Ductility of Drawn Pearlitic Steels)

  • 남원종
    • 소성∙가공
    • /
    • 제13권8호
    • /
    • pp.710-715
    • /
    • 2004
  • The effect of microstructural features on ductility of cold drawn pearlitic steels containing 0.52 ~ 0.92 wt%C was investigated. During wire drawing, reduction of area (Rh) increased initially with the progressive realignment of randomly oriented cementite, showed a maximum peak due to the completion of the alignment of most cementite, and decreased with thinning or fragmentation of the aligned cementite. Among factors on ductility, cementite thickness was found to be the most dominant microstructural feature for Rh of drawn pearlitic wires, regardless of transformation temperature and carbon content in steels.

국가균형발전 5개년계획의 추진전략과 주요내용 - 국토구조구축과 건설산업의 SOC투자를 중심으로 - (The Main Contents of the )

  • 정무용
    • 기술사
    • /
    • 제38권1호
    • /
    • pp.35-43
    • /
    • 2005
  • What are main contents of Balanced National Development Five Years Plan? We will study for contents and policies of the plan's six themes. Six themes of the plan are the drive strategy, the rearing of the worldwide progressive cluster, the local promotion in the strategic industry, the formation of the square national circulation road network, the consolidation of the metropolitan area and the independent drop-out region, and the fund and raising plan. And especially, we will study the details of the national land-structure network formation.

  • PDF

저온환경에서 복합재료 핀 연결부의 Bearing 강도에 관한 연구 (A Study of Bearing Strength on Composite Pinned-Joint at Low Temperature)

  • 허남일;이상연;김재훈;이영신;사정우;조승연;임기학;오영국;최창호;도철진;권면;이경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.413-418
    • /
    • 2001
  • Fundamental failure mode in a laminated composite pinned-joint is proposed to assess damage resulting from stress concentration in the plate. The joint area is a region with stress concentrations thus a complicated stress state exists. The modeling of damage in a laminated composite pinned-joint presents many difficulties because of the complexity of the failure process. In order to model progressive from initial to final, finite element methods are used rather than closed form stress analyses. Failure analysis must be a logical combination of suitable failure criteria and appropriate material properties degradation rules. In this study, the material properties which were obtained in previous study, the preparing process of the bearing strength test for a pinned joint CFRP composite plate subjected to in-plane loading at low temperature, and the FEM result of progressive damage model using ANSYS program are summarized to assess the structural safety of CFRP plate used in the magnetic supporting post of KSTAR(Korea Superconducting Tokamak Advanced Research).

  • PDF

Serum Levels of Interleukin-8 and Tumor Necrosis Factor-alpha in Coal Workers' Pneumoconiosis: One-year Follow-up Study

  • Lee, Jong-Seong;Shin, Jae-Hoon;Lee, Joung-Oh;Lee, Kyung-Myung;Kim, Ji-Hong;Choi, Byung-Soon
    • Safety and Health at Work
    • /
    • 제1권1호
    • /
    • pp.69-79
    • /
    • 2010
  • Objectives: Various cytokines induced by inhalation of coal dust may mediate inflammation and lead to tissue damage or fibrosis, such as coal workers' pneumoconiosis (CWP). Methods: To investigate the relevance of serum cytokines in CWP, the levels of serum interleukin-8 (IL-8) and tumor necrosis factor-alpha (TNF-${\alpha}$) as CWP biomarkers in 110 retired coal miners (22 controls and 88 CWP subjects) were related to cross sectional findings and 1-year progressive changes of the pneumoconiosis. Progressive changes of CWP were evaluated by paired comparison of chest radiographs. Analysis by a receiver operating characteristic curve assessed the biomarker potential of each cytokine. Results: The mean serum IL-8 level was significantly higher in CWP compared to controls and IL-8 levels correlated with the degree of CWP. The median serum TNF-${\alpha}$ level was significantly higher in subjects with progressive CWP compared to subjects without CWP progression. The area under the ROC curve for IL-8 (0.70) and TNF-${\alpha}$ (0.72) for CWP identification and progression, respectively, indicated the biomarker potential of the two cytokines. Serum cutoff values of IL-8 and TNF-${\alpha}$ were 11.63 pg/mL(sensitivity, 69%; specificity, 64%) and 4.52 pg/mL (sensitivity, 67%; specificity, 79%), respectively. Conclusion: The results suggest that high levels of serum IL-8 are associated with the presence of CWP and those of serum TNF-${\alpha}$ are associated with the progression of CWP.

18F-THK5351 PET Imaging in Nonfluent-Agrammatic Variant Primary Progressive Aphasia

  • Yoon, Cindy W;Jeong, Hye Jin;Seo, Seongho;Lee, Sang-Yoon;Suh, Mee Kyung;Heo, Jae-Hyeok;Lee, Yeong-Bae;Park, Kee Hyung;Okamura, Nobuyuki;Lee, Kyoung-Min;Noh, Young
    • 대한치매학회지
    • /
    • 제17권3호
    • /
    • pp.110-119
    • /
    • 2018
  • Background and Purpose: To analyze $^{18}F-THK5351$ positron emission tomography (PET) scans of patients with clinically diagnosed nonfluent/agrammatic variant primary progressive aphasia (navPPA). Methods: Thirty-one participants, including those with Alzheimer's disease (AD, n=13), navPPA (n=3), and those with normal control (NC, n=15) who completed 3 Tesla magnetic resonance imaging, $^{18}F-THK5351$ PET scans, and detailed neuropsychological tests, were included. Voxel-based and region of interest (ROI)-based analyses were performed to evaluate retention of $^{18}F-THK5351$ in navPPA patients. Results: In ROI-based analysis, patients with navPPA had higher levels of THK retention in the Broca's area, bilateral inferior frontal lobes, bilateral precentral gyri, and bilateral basal ganglia. Patients with navPPA showed higher levels of THK retention in bilateral frontal lobes (mainly left side) compared than NC in voxel-wise analysis. Conclusions: In our study, THK retention in navPPA patients was mainly distributed at the frontal region which was well correlated with functional-radiological distribution of navPPA. Our results suggest that tau PET imaging could be a supportive tool for diagnosis of navPPA in combination with a clinical history.

선량계산 및 최적화 알고리즘에 따른 치료계획의 영향 분석 (Analysis of Radiation Treatment Planning by Dose Calculation and Optimization Algorithm)

  • 김대섭;윤인하;이우석;백금문
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.137-147
    • /
    • 2012
  • 목 적: 알고리즘에 따른 치료계획의 영향을 분석하고 실제 치료계획을 수립할 때 고려사항을 적용하고, 나아가 최선의 치료계획을 수립하는 프로토콜을 제시하고자 한다. 대상 및 방법: 치료계획 시스템은 이클립스 10.0 (Eclipse 10.0, Varian, USA)이다. 선량계산의 알고리즘은 PBC (Pencil Beam Convolution)와 AAA (Anisotropic Analytical Algorithm)을 각각 적용하였고, 세기 조절 방사선 치료(IMRT)를 위한 최적화(Optimization) 알고리즘은 DVO (Dose Volume Optimizer 10.0.28), VMAT을 위한 최적화 알고리즘은 PRO II (Progressive Resolution Optimizer V 8.9.17)와 PRO III (Progressive Resolution Optimizer V 10.0.28)을 사용하였다. 실험을 위한 팬텀은 치료계획시스템에서 가상으로 만들었으며, $30{\times}30{\times}30$ cm의 규격에 밀도가 균일한 것(HU: 0)과 중간에 공기(HU: -1,000)로 가정되는 물질이 삽입한 된 비균질 팬텀으로 설정하였다. 실험은 먼저 팬텀(Phantom) 계획을 실시하여 일반적인 치료계획의 특징을 분석하고 그 내용을 토대로 실제 임상적용 할 치료계획을 수립하였다. 결 과: 균일한 밀도 팬텀에서 6 MV, 10 cm PDD (Percentage Depth Dose)는 PBC와 AAA는 모두 65.2%로 유사한 값을 나타냈지만, 비균질 팬텀에서 PDD는 저밀도 물질을 만나기 전까진 유사한 PDD 값을 보이다가 공기 영역에서 다른 선량곡선을 보여주고, 투과한 후에는 PDD 10 cm은 각각 75%, 73%이었다. 동일한 MU의 3차원 치료계획에서 보면, AAA 치료계획이 폐가 포함된 영역에서 저 선량으로 나타났다. 기관지와 폐의 영역이 포함된 경추 치료 환자의 2차원 대향 2문조사 치료계획을 15 MV을 이용하여 설계하였을 때, Conformity Index (ICRU 62)는 PBC 계산에서 0.95, AAA에서 0.93이었다. IMRT 치료계획은 DVO에서 보여지는 DVH가 선량계산 DVH와 동일하게 나타났다. 하지만 AAA으로 선량계산을 하였을 때는 DVO에서 조건을 만족하는 결과가 선량계산에서는 선량부족으로 나타났다. PRO II을 이용한 VMAT 치료계획은 최적화 할 때는 만족스런 결과를 얻었지만, 선량계산을 실시하였을 때는 저밀도 영역이 선량 부족으로 나타났다. 하지만 PRO III에서 같은 조건을 1회 더 최적화함으로써 최적화 결과와 선량계산 결과가 유사하였다. 결 론: 본 연구에서는 선량계산 알고리즘의 옳고 그름을 판단하지 않는다. 알고리즘이 나타내는 선량 분포의 특성을 분석하고, 특히 최적화가 필요한 IMRT나 VMAT 치료계획에서 최적화 알고리즘의 요인도 치료계획을 수립할 때 고려함으로써 최적의 치료계획을 위한 방법을 제시하고자 한다.

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.45-51
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system’s capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF

주택면적의 변화에 따른 가정용 초소형 연료전지 코제너레이션 시스템의 경제성 분석에 관한 연구 (A Study on the Economic Evaluation with Super-Micro Fuel Cell Home Cogeneration System by Varying the Floor Area of House)

  • 노철우;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 2008
  • The fuel cell system is environment-friendly and energy efficient system. Especially, the fuel cell cogeneration systems providing heat and electricity to buildings have been developed and applied to a lot of sites in the world to cope with the global warming and $CO_2$ emission problem. This paper presents the result of study on the economic evaluation with super-micro fuel cell (SMFC) cogeneration system by varying the floor area ($132m^2{\sim}331m^2$) of the house, whose system capacity ranges from 0.10 kWe to 0.50 kWe. The electricity demand, heat demand, saved energy cost, and the simple pay-back period have been simulated for the various capacities of fuel cell cogeneration system. As a result, this study suggests the fuel cell system's capacity decision strategy for a given house area. Contrary to conventional design assumptions, the smaller capacity fuel cell cogeneration system is appropriate for the house of large floor area to defense the progressive electricity tax, and the larger capacity fuel cell cogeneration system is appropriate for the house of small floor area to sell the electricity.

  • PDF