• Title/Summary/Keyword: profile measurement

Search Result 912, Processing Time 0.033 seconds

Noninvasive Depthwise Temperature Measurement in Skin Tissue Using Laser Speckle Imaging Technique (레이저 스펙클 이미징 기법을 이용한 피부 조직의 깊이 방향 비침습적 온도 측정)

  • Jakir Hossain Imran;Noemi Correa;Jung Kyung Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.2
    • /
    • pp.74-81
    • /
    • 2024
  • Accurate tissue temperature monitoring during clinical procedures, such as laser therapy or surgery, is crucial for ensuring patient safety and treatment efficacy. Noninvasive techniques are essential to prevent tissue disturbance while providing real-time temperature data. However, current methods often struggle to accurately measure temperature at various depths within the skin, which is essential to avoid damage to surrounding healthy tissues due to excessive heat. In response to this challenge, we developed a confocal imaging system that utilizes the laser speckle imaging (LSI) technique for precise depthwise temperature monitoring. LSI uses laser light scattering to capture subtle changes in speckle patterns on the skin's surface due to temperature fluctuations within the tissue. By analyzing these changes, LSI enables accurate depth-resolved temperature measurements. This technique enhances the precision and safety of medical procedures, offering significant potential for broader clinical applications, improved patient outcomes, and better thermal management during interventions.

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF

A comparative study on health promotion lifestyles and attitudes between unmarried and married pregnant women (미혼임부와 기혼임부 건강증진행위 차이에 관한 비교연구)

  • 김혜숙;최연순
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.2
    • /
    • pp.255-268
    • /
    • 1993
  • This descriptive correlational research was conducted to compare the relationship between self-esteem performance of antenatal care and health pro-motion lifestyles for unmarried and married pregnant women. The sample consisted of 94 married women attending one general hospital and residing in Seoul and 82 unmarried women from two social institutes for unmarried women. The tool used for this study was a structured questionnaire which was developed and revised by the researcher. The tool consisted of 12 items related to demographic characteristics, 10 items on self-esteem measurement, 20 items on performance of antenatal care and 37 items on health promotion lifestyle profile. The data collected from the interviews were analyzing using the SPSS, yielding frequencies, percentiles, means, standard deviations, t-test, ANOVA, Pearson’s Product Moment Correlation. The results of this study are as follows : 1) The demographic variables for the two groups were heterogenous except for religion. 2) The results of the comparison between the two groups were significantly different for self-esteem, married women(mean 20.41, standard deviation 3. 94) had higher scores on self-esteem than unmarried women(mean 24.02, standard deviation 4.11), (t=-5.91, p .001) 3) There was a stastically significant difference between the two groups on the health promotion lifestyle profile. The married women had higher scores on the health promotion lifestyle profile (t=7.22, p〈.001) 4) The score for married women on performance of antenatal care has higher than the score for unmarried women(t=8.83, p〈.001) 5) With regard to the relationship between health promotion lifestyle and performance of antenatal care and self-esteem, the correlation coefficient between self-esteem and health Promotion lifestyle for married women was .45, between per formance of antenatal care and health promotion lifestyle, .54, between self-esteem and performance of antenatal care, .32. For the unmarried women, between self-esteem and health promotion lifestyle, .39, between performance of antenatal care and health promotion lifestyle, .67, between self-esteem and performance of antenatal care, .30. 6) There was a statistically significant different between the two groups on all subconcepts of the health promotion lifestyle profile (p〈.001). 7) Comparison of the order of the scores between the two groups for the married women showed that the highest score was for nutrition, then self-actualization, interpersonal support, health responsibility, stress management and exercise in that order. For the unmarried women the highest score was for self-actualization followed by nutrition, interpersonal support, stress management, health responsibility, and exercise in that order. The score in the exercise domain was lowest in both groups. In conclusion, on the basis of the results of this study, resources and protection facilities for unmarried pregnant women could be improved through government policies and health care policies that would allow unmarried women to utilize significant social support resources and actualize health pro-motion lifestyles. Nursing should offer interventions to increase psychosocial adjustment and support tp improve the quality of life for unmarried pregnant women and further to promote improved growth and development of the infants.

  • PDF

Plasma Etching Process based on Real-time Monitoring of Radical Density and Substrate Temperature

  • Takeda, K.;Fukunaga, Y.;Tsutsumi, T.;Ishikawa, K.;Kondo, H.;Sekine, M.;Hori, M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.93-93
    • /
    • 2016
  • Large scale integrated circuits (LSIs) has been improved by the shrinkage of the circuit dimensions. The smaller chip sizes and increase in circuit density require the miniaturization of the line-width and space between metal interconnections. Therefore, an extreme precise control of the critical dimension and pattern profile is necessary to fabricate next generation nano-electronics devices. The pattern profile control of plasma etching with an accuracy of sub-nanometer must be achieved. To realize the etching process which achieves the problem, understanding of the etching mechanism and precise control of the process based on the real-time monitoring of internal plasma parameters such as etching species density, surface temperature of substrate, etc. are very important. For instance, it is known that the etched profiles of organic low dielectric (low-k) films are sensitive to the substrate temperature and density ratio of H and N atoms in the H2/N2 plasma [1]. In this study, we introduced a feedback control of actual substrate temperature and radical density ratio monitored in real time. And then the dependence of etch rates and profiles of organic films have been evaluated based on the substrate temperatures. In this study, organic low-k films were etched by a dual frequency capacitively coupled plasma employing the mixture of H2/N2 gases. A 100-MHz power was supplied to an upper electrode for plasma generation. The Si substrate was electrostatically chucked to a lower electrode biased by supplying a 2-MHz power. To investigate the effects of H and N radical on the etching profile of organic low-k films, absolute H and N atom densities were measured by vacuum ultraviolet absorption spectroscopy [2]. Moreover, using the optical fiber-type low-coherence interferometer [3], substrate temperature has been measured in real time during etching process. From the measurement results, the temperature raised rapidly just after plasma ignition and was gradually saturated. The temporal change of substrate temperature is a crucial issue to control of surface reactions of reactive species. Therefore, by the intervals of on-off of the plasma discharge, the substrate temperature was maintained within ${\pm}1.5^{\circ}C$ from the set value. As a result, the temperatures were kept within $3^{\circ}C$ during the etching process. Then, we etched organic films with line-and-space pattern using this system. The cross-sections of the organic films etched for 50 s with the substrate temperatures at $20^{\circ}C$ and $100^{\circ}C$ were observed by SEM. From the results, they were different in the sidewall profile. It suggests that the reactions on the sidewalls changed according to the substrate temperature. The precise substrate temperature control method with real-time temperature monitoring and intermittent plasma generation was suggested to contribute on realization of fine pattern etching.

  • PDF

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.

A Trial for Development of Health Profile (KHP 1.0) to Measure the Self-Perceived Health Status of Korean (한국인의 자가평가 건강수준 측정도구(KHP 1.0) 개발)

  • Yang, Jin-Sun;Chun, Jin-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • Objectives : The 1990s has seen advances in the conceptualization of self-perceived health status which has important roles for individual health and the quality of life. Many types of standardized questionnaires have been developed with the current wide use of SF-36, NHP, andEuroQol. However, the outcomes of these tools may be different with regard to regional, cultural and emotional backgrounds. The purpose of this study was to trial the development of a Korean Health Profile (KHP 1.0) to measure the self-perceived health stati of Koreans. Methods : The KHP 1.0 was designed on the basis of the Medical Outcome Study Form 36 (SF-36), the Nottingham Health Profile (NHP), and the EuroQOL. It was composed of 9 scales; physical functioning, role limitation-physical, pain, general health, energy, social isolation, sleep, role limitation-emotional, and e-motional health. Self-reported chronic disease conditions, and the Zung's Self-Rating Depression Scale (SDS), were also checked for the evaluation of clinical validity. This study was conducted, from December 2000 to January 2001, on 800 middle-aged parents, with four high school students, with 100 retest sets being conducted two weeks later. From the 800 subjects there were 588 complete responses (effective response 73.5%). The reliability of the test-retest results, and the factor analysis on the validity of the KHP 1.0 components, were evaluated using the SPSS (ver 10.0) software. Results : The reliability of the KHP 1.0 was good with Cronbach's alpha (>0.6), test-retest correlation coefficients (>0.5), but with no significant differences from the paired t-test. From the psychometric validity tests, the 9 scales of the KHP 1.0 were divided into two components; physical and mental, and trimmed to the established model with 55% of the total variance, with the exception of role limitation-emotional. The clinical validity on the basis of the comparison for the four characteristic groups; healthy, physical conditions only, mental conditions only, and physical and mental conditions were also good. Conclusions : The KHP 1.0 appears to be a valid measurement tool of self-perceived health stati of Koreans, although there are limitations, i.e. sample size was too small, a limited number of middle-aged subjects, and it was based on unconfirmed diagnoses, etc. Therefore, further study is required to standardize the assessment.

Protein Composition of Domestic and Glyphosate-Tolerant Soybean (국내산 및 제초제 내성 콩의 단백질 조성 분석)

  • Wei, Chun-Hua;Sok, Dai-Eun;Yang, Yun-Hyoung;Oh, Sang-Hee;Kim, Hyoung-Chin;Yoon, Won-Kee;Kim, Hwan-Mook;Kim, Mee-Ree
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.4
    • /
    • pp.470-475
    • /
    • 2006
  • In order to elucidate the differences of protein profiles among soybean cultivars, the protein composition of three conventional domestic soybean cultivars and two imported ones including glyphosate-tolerant HS2906 was analyzed by total nitrogen measurement, amino acid analysis and PAGE/densitometry. There were no statistically significant differences in the levels of any amino acid, including aromatic amino acids, between glyphosale-tolerant soybean and the conventional soybean WS82. In the extraction of protein, the SDS/buffer system was more efficient than the defatting/water system. The SDS-PAGE/densitometry analysis showed that there was a similar profile of proteins among cultivars, although the amount of total protein ranged from 380.2 mg/g to 423.9 mg/g. In addition, there was no discernable difference of protein profile between glyphosate- tolerant soybean (total protein amount, 380.2 mg/g) and the conventional soybean WS82 (390.2 mg/g), although the amount of ${\beta}$-conglycinin (55 kDa) was lower in glyphosate-tolerant soybean. Meanwhile, the amount of 25 kDa protein was greater in domestic soybean cultivars than imported ones. Thus, normal PAGE/ densitometry method would be useful to analyze the difference in protein profiles of soybean proteins, and furthermore Evaluate the protein profile of proteins between GMO and conventional soybean.

A ROENTGENOCEPHALOMETRIC STUDY OF KOREAN SOFT TISSUE PROFILE (한국인 악안면 연조직에 관한 두부방사선 계측학적 연구)

  • Cheon Suck, Oh
    • The korean journal of orthodontics
    • /
    • v.12 no.2
    • /
    • pp.79-93
    • /
    • 1982
  • The purpose of orthodontic treatment is to achieve normal occlusion and good facial esthetics for individual patients. To produce harmonized facial balance, treatment planning for patient who require orthodontic treatment should include both a hard tissue and soft tissue cephalometric analysis. Author studied to derive the normal standards of soft tissue profile in Koreans by roentgenocephalometric analysis. For this study 12 soft tissue profile landmarks were plotted and 23 linear length, 9 soft tissue thickness, 8 vertical height length, 12 angles of soft tissue profile, and 3 vertical proportion were measured. The subjects consisted of 166 males and 209 females from 7 to 19 years with normal occlusion and acceptable profiles, and were divided into five groups according to age. The obtained results were as follows; 1. From the basis of N-Pog (Nasion-Pogonion) plane, the growth of facial soft tissue in the middle region especially nose area was greater than others facial region. 2. From the basis of G-Pog' (Glabella-soft tissue Pogonion) plane, the values of linear measurement of soft tissue Nasion and Inferior labial sulcus decreased and nose tip grew forward as growing older. 3. The growth of the facial soft tissue thickness was greatest in superior labial sulcus and the thickness of soft tissue nasion gradually became thinner as growing old. 4. The thickness of upper and lower lip was 14.47mm, 14.57mm in adulr male, 12.76mm, 13.78mm in adult female. 5. The soft tissue thickness of the lower lip was thicker than that of upper lip in all age groups and both sexes, 6. The vertical length of the upper and lower lips were 25.04mm, 49.97mm in adult male and 23.50mm, 48.39mm in adult female. 7. By the significant test, there were significant difference between male and female in fifth adult group on all vertical length measurements of lower face. 8. In fifth adult group, the perpendicular distance from LS, LI to Steiner's line and Ricketts' esthetic line were as follow; Steiner line to LS, LI were 7.98mm, 5.84mm in male. Steiner line to LS, LI were 6.71mm, 5.08mm in female. Ricketts' esthetic line to LS, LI were -0.40mm, 1.72mm in male. Ricketts' esthetic line to Ls, LI were -1.38mm 0.65mm in female. 9. In fifth adult group, the facial convexity angle and lower facial component angle were $171.17^{\circ}142.94^{\circ}$ in male and $172.5^{\circ}$, $144.41^{\circ}$ in female.

  • PDF

미세금형 가공을 위한 전기화학식각공정의 유한요소 해석 및 실험 결과 비교

  • Ryu, Heon-Yeol;Im, Hyeon-Seung;Jo, Si-Hyeong;Hwang, Byeong-Jun;Lee, Seong-Ho;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.81.2-81.2
    • /
    • 2012
  • To fabricate a metal mold for injection molding, hot-embossing and imprinting process, mechanical machining, electro discharge machining (EDM), electrochemical machining (ECM), laser process and wet etching ($FeCl_3$ process) have been widely used. However it is hard to get precise structure with these processes. Electrochemical etching has been also employed to fabricate a micro structure in metal mold. A through mask electrochemical micro machining (TMEMM) is one of the electrochemical etching processes which can obtain finely precise structure. In this process, many parameters such as current density, process time, temperature of electrolyte and distance between electrodes should be controlled. Therefore, it is difficult to predict the result because it has low reliability and reproducibility. To improve it, we investigated this process numerically and experimentally. To search the relation between processing parameters and the results, we used finite element simulation and the commercial finite element method (FEM) software ANSYS was used to analyze the electric field. In this study, it was supposed that the anodic dissolution process is predicted depending on the current density which is one of major parameters with finite element method. In experiment, we used stainless steel (SS304) substrate with various sized square and circular array patterns as an anode and copper (Cu) plate as a cathode. A mixture of $H_2SO_4$, $H_3PO_4$ and DIW was used as an electrolyte. After electrochemical etching process, we compared the results of experiment and simulation. As a result, we got the current distribution in the electrolyte and line profile of current density of the patterns from simulation. And etching profile and surface morphologies were characterized by 3D-profiler(${\mu}$-surf, Nanofocus, Germany) and FE-SEM(S-4800, Hitachi, Japan) measurement. From comparison of these data, it was confirmed that current distribution and line profile of the patterns from simulation are similar to surface morphology and etching profile of the sample from the process, respectively. Then we concluded that current density is more concentrated at the edge of pattern and the depth of etched area is proportional to current density.

  • PDF

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF