• Title/Summary/Keyword: profile measurement

Search Result 912, Processing Time 0.031 seconds

Effect of Microcurrent stimulation and Combined exercise on Body composition and Blood lipid profile in Young obese women (미세전류자극과 복합운동이 비만 여대생의 체성분과 혈중지질성분 변화에 미치는 효과)

  • Yong-Taek Rhim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.1104-1115
    • /
    • 2023
  • The present study aims to verify the usefulness of microcurrent stimulation as an effective intervention for managing body shape. Thirty female college students with a percentage body fat of 30% or more participated as subjects and belonged to the one of three groups; control group, combined exercise group, microcurrent stimulation group. Based on the results of analyzing the measurement data from pre- and post-intervention for four weeks for each group, the following conclusions were obtained. There was no statistically significant difference in all measured variables in the control group. However, waist circumference and TC were significantly reduced in the combined exercise group, and also weight, percentage body fat, waist circumference, and apolipoprotein were significantly reduced in microcurrent stimulation group. Considering the above conclusions, it can be suggested that microcurrent stimulation could be an effective intervention to improve body composition and blood lipid profile to have a healthy body.

A Systematic Study on the Multifaceted Lifestyle Assessment Tools For Community-dwelling Elderly: Trend and Application Prospect (지역사회 거주 고령자의 라이프스타일 측정도구에 관한 조사: 경향과 활용전망)

  • Park, Kang-Hyun;Won, Kyung-A;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.8 no.3
    • /
    • pp.7-29
    • /
    • 2019
  • Objective: The purpose of this study is to analyze comprehensive lifestyle assessment and other assessments which evaluate essential lifestyle factors, including physical activity, nutrition and activity participation. Methods: To analyze the comprehensive lifestyle assessment, from January 2001 to June 2019, a literature search was conducted using the CINANL, NDSL, PubMed, and RISS databases. The search terms were 'lifestyle assessment' OR 'lifestyle profile' OR 'lifestyle test'. In terms of other assessments of essential factors of lifestyle, from January 2010 to June 2019, articles were searched using similar databases. The search terms were 'physical activity assessment' OR 'physical activity participation profile', 'nutrition assessment', 'activity participation assessment' OR 'activity participation and lifestyle'. Results: A total of 4,165 articles were obtained, and finally 31 articles were selected according to the inclusion criteria. Among 31 articles, there were five with comprehensive lifestyle assessments, and all of them were self-report questionnaires. The most popular assessments were the Health Enhancement Lifestyle Profile (HELP) and the Health-Promoting Lifestyle Profile (HPLP), which were used in three articles (33%). In terms of assessment of physical activity, the most frequently used evaluation method was the self-report questionnaire, which was used in seven articles (58%) followed by objective assessments, which were used in four articles (33%). It was demonstrated that the Mini-Nutritional Assessment (MNA) was the most frequently used for nutrition assessment in the elderly. There were five types of assessment tool used for activity participation. Among them, meaningful activity participation assessment (MAPA) was the most frequently used tool. Conclusion: As a result of the systematic review, it was found that there are 21 assessments related to the evaluation of lifestyle in the elderly. Most assessments employed the self-report questionnaire method and mainly evaluated frequency and duration of participation in drinking, smoking, exercise, nutrition and social activities. Assessments of essential lifestyle factors were the self-report questionnaire method and the participation and frequency of activity. Therefore, by analyzing assessment tools, types of items and measurement methods of comprehensive lifestyle assessments and other assessment of essential lifestyle factors, this study provides the basic data on which to develop a standardized assessment tool that can evaluate the multifaceted lifestyle profile of the elderly.

Adaptive Color Correction Method to Monitor in Color Laser Printer (모니터에 적응적인 칼라 레이저 프린터의 색 변환 방법)

  • Jang, In-Su;Son, Chang-Hwan;Kim, Kyung-Man;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.63-68
    • /
    • 2010
  • The Color Management System in recent printers adopts ICC profiles for both monitors and printers. However, the ICC profile doesn't contain the characteristics of reproduced color on each monitor, because the color on each monitor is changed by user adjustment such as color temperature, brightness, and contrast adjustment. It is also depended on the backlight type and lifetime. As a result, unwanted color is reproduced on the printed paper, not like that on the monitor. To overcome the color difference between monitors and printers, it is needed to control the information of ICC profile. That is, first, the ICC profile is generated by the measurement of monitors having user set, then, through the CMS, the color on monitors can be produced on printed paper. However, it is difficult to apply the above system for normal users due to absence of measuring equipment and time consuming process. Therefore, this paper proposes a novel color matching technique based on the estimation of condition for each monitor having user set. The estimation is performed by a simple comparison visual test using a test image on printed paper and monitor. Then, the condition of monitor is applied to the ICC profile. As a result, the new ICC profile contains the color difference between user monitor and printer. The experimental results show the printed images using our proposed method have almost similar color with those on monitors.

Tunnel Reverse Engineering Using Terrestrial LiDAR (지상LiDAR를 이용한 터널의 Reverse Engineering)

  • Cho, Hyung Sig;Sohn, Hong Gyoo;Kim, Jong Suk;Lee, Suk Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.931-936
    • /
    • 2008
  • Surveying by using terrestrial LiDAR(Light Detection And Ranging) is more rapid than by using total station which enables tunnel section profile surveying to be done in suitable time and minimize centerline error, occurrence of overcut and undercut. Therefore, utilization of terrestrial LiDAR has increased more and more in section profile survey and measurement field Moreover, studies of terrestrial LiDAR for accurate and efficient utilization is now ongoing vigorously. Average end area formula, which was generally used to calculate overcut and undercut, was compared with existing methods such as total station survey and photogrammetry. However, there are no criteria of spacing distance for calculating overcut and undercut through terrestrial LiDAR surveying which can acquire 3D information of whole tunnel. This research performed reverse engineering to decide optimal spacing distance when surveying tunnel section profile by comparing whole tunnel volume and tunnel volume in difference spacing distance. This result was utilized to produce CAD drawing for the test tunnel site where there is no design drawings. In addition to this, efficiency of LiDAR and accuracy of CAD drawing was compared with targetless total station surveying of tunnel section profile. Finally, error analysis of target coordinate's accuracy and incidence angle was done in order to verify the accuracy of terrestrial LiDAR technology.

Performance Evaluation of Stealth Chamber as a Novel Reference Chamber for Measuring Percentage Depth Dose and Profile of VitalBeam Linear Accelerator (VitalBeam 선형가속기의 심부선량백분율과 측방선량분포 측정을 위한 새로운 기준 전리함으로서 스텔스 전리함의 성능 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Kang, Seong-Hee;Kang, Sang-Won;Kim, Kyeong-Hyeon;Jung, Jae-Yong;Shin, Young-Joo;Suh, Tae-Suk;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2018
  • The purpose of this study is to evaluate the performance of a "stealth chamber" as a novel reference chamber for measuring percentage depth dose (PDD) and profile of 6, 8 and 10 MV photon energies. The PDD curves and dose profiles with fields ranging from $3{\times}3$ to $25{\times}25cm^2$ were acquired from measurements by using the stealth chamber and CC 13 chamber as reference chamber. All measurements were performed with Varian VitalBeam linear accelerator. In order to assess the performance of stealth chamber, PDD curves and profiles measured with stealth chamber were compared with measurement data using CC13 chamber. For PPDs measured with both chambers, the dosimetric parameters such as $d_{max}$ (depth of maximum dose), $D_{50}$ (PDD at 50 mm depth), and $D_{100}$ (PDD at 100 mm depth) were analyzed. Moreover, root mean square error (RMSE) values for profiles at $d_{max}$ and 100 mm depth were evaluated. The measured PDDs and profiles between the stealth chamber and CC13 chamber as reference detector had almost comparable. For PDDs, the evaluated dosimetric parameters were observed small difference (<1%) for all energies and field sizes, except for $d_{max}$ less than 2 mm. In addition, the difference of RMSEs for profiles at $d_{max}$ and 100 mm depth was similar for both chambers. This study confirmed that the use of stealth chamber for measuring commission beam data is a feasible as reference chamber for fields ranging from $3{\times}3$ to $20{\times}20cm^2$. Furthermore, it has an advantage with respect to measurement of the small fields (less than $3{\times}3cm^2$ field) although not performed in this study.

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Characteristics of Dose Distribution at Junctional Area Using the Divergency Cutout Block in the Abutted Field of Photon and Electron Beams (광자선과 전자선의 인접조사에서 선속 퍼짐현상이 고려된 전자선 차폐물을 이용한 접합 조사면의 선량분포 특성)

  • Im, In-Chul;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.168-173
    • /
    • 2011
  • This study investigated characteristics of dose distribution at junction field of X-ray and electron beams according to the method for fabricating the insert block on the electron cone. Insert block were fabricated to the divergency cutout block and the straight cutout block. For the 6 MV X-ray and 10 MeV nominal energy of electron beam, we was adjacent to the light field of X-ray and electron beam at a surface of matrix chamber and measured to beam profile of abutted field in the 0, 1, 2, 3 cm measurement depth. As a result, characteristics of dose distribution at junction field, straight block was existent that over dose area exceed the give dose more than 5% and under dose area with a rapid change in dose distribution. However, divergency block had remarkably decreased the over dose area caused by the lateral scattering effects of decrease, and being existed uniformity dose distribution in the junction field. Therefore, divergency block were the benefits of radiation dose delivery, in order to applied the clinical, measurement of electron beams according to the fabrication method of the block should be considered carefully.

2D/3D Visual Optical Inspection System for Quad Chip (Quad Chip 외관 불량 검사를 위한 2D/3D 광학 시스템)

  • Han, Chang Ho;Lee, Sangjoon;Park, Chul-Geon;Lee, Ji Yeon;Ryu, Young-Kee;Ko, Kuk Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.684-692
    • /
    • 2016
  • In the manufacturing process of the LQFP/TQFP (Low-profile Quad Flat Package/Thin Quad Flat Package), the requirement of a 3 dimensional inspection is increasing rapidly and a 3D inspection of the shape of a chip has become an important report of quality control. This study developed a 3 dimensional measurement system based on PMP (Phase Measuring Profilometry) for an inspection of the LQFP/TQFP chip and image processing algorithms. The defects of the LQFP/TQFP chip were classified according to the dimensions. The 2 dimensional optical system was designed by the dorm illumination to achieve constant light distribution, In the 3 dimensional optical system, PZT was used for moving 90 degree in phase. The problem of 2 ambiguity was solved from the measured moir? pattern using the ambiguity elimination algorithm that finds the point of ambiguity and refines the phase value. The proposed 3D measurement system was evaluated experimentally.

Accuracy of soft tissue Profile change prediction in mandibular set-back surgery patients: a comparison of Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5) (하악골 후퇴 수술 환자의 연조직 측모 예측의 정확성: Quick Ceph Image $Pro^{TM}$(ver 3.0)와 $V-Ceph^{TM}$(Ver 3.5)의 비교)

  • Kim, Myoung-Kyun;Choi, Yong-Sung;Chung, Song-Woo;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.216-226
    • /
    • 2005
  • The purpose of this study was to test and compare the accuracy and reliability of soft tissue profile predictions generated from two computer software programs (Quick Ceph Image $Pro^{TM}$ (ver 3.0) and $V-Ceph^{TM}$(ver 3.5)) for mandibular set-back surgery. The presurgical and postsurgical lateral cephalograms of 40 patients (20 males and 20 females) were traced on the same acetate paper with the reference taken as the cranial base outline. The presurgical skeletal outlines were digitized onto each computer program and the mandible was moved to mimic the expected surgical procedure with reverence to the mandibular anterior border and lower incisor position of the actual postsurgical skeletal outline. The soft tissue profile was generated and the amount and direction of skeletal movement was calculated with each software. The predicted soft tissue profile was compared to the actual postsurgical soft tissue profile. There were differences between the actual and the predicted surgical soft tissue profile charges in the magnitude and direction, especially the upper lip. lower lip and the soft tissue chin (P<0.05). Quick Ceph had more horizontal measurement errors and thickness errors for the upper lip and lower lip, but V-Ceph had more vertical measurement errors of the lower lip (P<0.05). There was a positive correlation between the prediction errors and the amount of mandibular movements in the vertical position of Sn, the horizontal position of Ls and the upper lip thickness for V-Ceph, and there was a negative correlation in the horizontal position and the thickness of the lower lip for Quick Ceph (P<0.05). However all of the Prediction errors of both imaging softwares were ranged within 3mm, and this was considered to be allowable clinically.

Delay Spread Measurement and Analysis in 3 GHz and 6 GHz Indoor Environments (3 GHz, 6 GHz 실내 환경의 지연 확산 측정 및 분석)

  • Lee, Seong-Hun;Lee, Hwa-Choon;Cho, Byung-Lok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.15-20
    • /
    • 2020
  • In this paper, delay diffusion for exhibition hall and conference room was measured and analyzed in the indoor environment of the building. Scenarios for the indoor environment of the two buildings were written. also, the system configuration and measurement methods were conducted under the same conditions. The measurement conditions were set to 3 GHz and 6 GHz of center frequencies and analysis band selected 2 GHz. The measurement system consisted of vector network analyzer, power amplifier, omni-directional transmit and receive antenna, and transmission line. According to the indoor environment scenario of the two buildings, the location of the receiving antenna was divided into three zones based on the location of the transmitting antenna and this was measured at 1 m intervals according to 18 locations. The power delay profiles, RMS delay spread, and K-factor results of two buildings were compared and analyzed.