• Title/Summary/Keyword: profile measurement

Search Result 910, Processing Time 0.025 seconds

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • 지영훈;이동한;류성렬;권수일;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.45-57
    • /
    • 1997
  • It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine, European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induces the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. For measuring the absorbed doses and the dose distribution of fast neutron beam, we used IC-17 and IC-18 ion chambers manufactured by A-150 plastic(tissue-equivalent material), IC-17M ion chamber manufactured by magnesium, TE gas and Ar gas, and RDM 2A electrometer. The magnitude of gamma-contamination intermingled with fast neutron beam was about 13% at 5cm depth of standard irradiated field, and increased as the depth was increased. At the central axis the maximum dose depth and 50% dose depth were 1.32cm and 14.8cm, respectively. The surface dose rate was 41.6-54.1% throughout the entire irradiated fields and increased as the irradiated fields were increased. Beam profile was that the horn effect of about 7.5% appeared at 2.5cm depth and the flattest at 10cm depth.

  • PDF

Implementation of 3D Road Surface Monitoring System for Vehicle based on Line Laser (선레이저 기반 이동체용 3차원 노면 모니터링 시스템 구현)

  • Choi, Seungho;Kim, Seoyeon;Kim, Taesik;Min, Hong;Jung, Young-Hoon;Jung, Jinman
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.101-107
    • /
    • 2020
  • Road surface measurement is an essential process for quantifying the degree and displacement of roughness in road surface management. For safer road surface management and quick maintenance, it is important to accurately measure the road surface while mounted on a vehicle. In this paper, we propose a sophisticated road surface measurement system that can be measured on a moving vehicle. The proposed road surface measurement system supports more accurate measurement of the road surface by using a high-performance line laser sensor. It is also possible to measure the transverse and longitudinal profile by matching the position information acquired from the RTK, and the velocity adaptive update algorithm allows a manager to monitor in a real-time manner. In order to evaluate the proposed system, the Gocator laser sensor, MRP module, and NVIDIA Xavier processor were mounted on a test mobile and tested on the road surface. Our evaluation results demonstrate that our system measures accurate profile base on the MSE. Our proposed system can be used not only for evaluating the condition of roads but also for evaluating the impact of adjacent excavation.

Measurement of Refractive Index Profile of GRIN plastic optical fiber using Moire interferometry (모아레 간섭 방법을 이용한 GRIN 플라스틱 광 섬유의 굴절률 측정에 관한 연구)

  • 이현호;유장훈;채규민;주홍렬;박승한
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.204-205
    • /
    • 2002
  • 근래 활발히 연구되고 있는 광통신 분야에서 광섬유는 중요한 위치를 차지하고 있으며 현재까지 여러 가지 연구가 되어져 왔다. 광섬유 중 플라스틱 광섬유는 근거리 광통신 분야에 사용을 위해서 활발한 연구와 개발이 이루어지고 있다. 이러한 광섬유의 특성을 결정짓는 중요한 요소 중 하나가 광섬유의 굴절률 분포이다. 광섬유의 굴절률 분포는 광 전송특성을 결정짓는 요소로서 이러한 이유 때문에 좋은 전송특성을 위해 GRIN 광섬유의 개발과 연구가 이루어져 왔다. (중략)

  • PDF

A Study on Flow Characteristics of a Ginseng Cleaner Using PIV (PIV에 의한 인삼세척기의 특성연구)

  • 송치성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.140-145
    • /
    • 2000
  • The objective of experimental study is to apply simultaneous measurement by PIV(Particle Image Velocimetry) to high_speed flow characteristics within ginseng cleaner model. Three different kinds of flow rate(15.20 27ℓ/min) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. The instantaneous velocity distribution time0mean velocity distribution and velocity profile are represented quantitatively for the deeper understanding of the flow characteristics in a ginseng cleaner model.

  • PDF

Experimental Study on High Temperature Air Regenerative Combustion System (축열식 고온공기 연소시스템에 대한 실험적 연구)

  • Yang, B.O.;Lim, I.G.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.189-200
    • /
    • 1999
  • Combustion characteristics of a regenerative combustor for high temperature air combustion have experimentally studied. Temperature measurement on regenerative ceramic material and combustor has been carried out with changing equivalence ratio at constant turn-over period. Stable and unstable combustion region have been found and also detailed averaged temperature profile with respect to various air flow conditions have been obtained.

  • PDF

Design, Implementation and Evaluation of Resonant DC/DC Converter Using Low-Profile Magnetic Device (박형 자기소자를 이용한 공진형 직류/직류 컨버터의 설계${\cdot}$제작 및 평가)

  • Ko Jiemyung;Choi Byungcho;Cha Honnyong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.350-354
    • /
    • 2004
  • This paper presents theoretical and practical details about the design, implementation, and performance of a series resonant do-to-dc converter using planar magnetics. Result of sinusoidal analysis are used to predict the voltage gain and conversion efficiency. The performance of a prototype converter is presented including the efficiency measurement and theoretical loss breakdown.

  • PDF

MEASUREMENT OF LINE PROFILE STEEPNESS AS A POSSIBLE TOOL FOR DEDUCING A TOTAL MAGNETIC FLUX NEAR A NEUTRAL LINE

  • GRIGORYEV V. M.;KOBANOV N. I.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.233-234
    • /
    • 1996
  • For obtaining estimates of a total magnetic flux, we propose to use measurements of ${\partial}I/{\partial}{\lambda}$. obtained by a modulation method which is formally identical to Stokes V-parameter measurements. In this case the polarization is not analyzed. It is advisable to use in measurements two parts of the spectral line wing.

  • PDF

Studies on the Flame Temperature Measurement of the Propagating Flame (전파화염에서의 화염온도측정에 관한 연구)

  • ;;Jeung, In Seuck
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.4
    • /
    • pp.182-189
    • /
    • 1977
  • The propagating flame temperature of the Propane-Air premixture by using 30.$\mu$ and 50.$\mu$ diameter platinum sensing wires, that is, Two Wires Correction Method, Through the constant volume burining inside the 150mm diameter, 30mm height combustion chamber under the circumstances of the atomospheric pressure, and the room temperature was determined. Also the temperature distribution across High Temperature Region, i.e. Flame Front, and the temperature profile behind the flame the front have been obtained.

A THREE-DINENSIONAL MEASURING TECHNIQUE APPLIED TO FORGING PRESS MACHINE

  • Xiao, Sun;Shimomoto, Yoichi;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.138-141
    • /
    • 1995
  • This paper describes a 3-dimensional measuring method for cylindrical huge ingot pressed with forging machine. Target ingot we consider here is rotated around a fixed axis during measurement. Using an image processing technique every profile of cross-section is obtained, and 3D image is reconstructed. One method to calibrate the system setting is also presented. Experimental results reveal that the method are applicable and the algorithm is feasible.

  • PDF