• Title/Summary/Keyword: proficiency analytical testing

Search Result 30, Processing Time 0.023 seconds

Sample Development for Quality Control of Formaldehyde and Proficiency Analytical Testing (정도관리용 포름알데히드 시료개발 및 분석능력평가)

  • Park, Hae Dong;Jang, Miyeon;Park, Seunghyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Objectives: The objective of this study was to develop formaldehyde samples for quality control (QC) and to test the applicability of proficiency analytical testing in Korea. Methods: We made formaldehyde samples with certified standard solutions (formaldehyde in water or acetonitrile) and 2,4-dinitrophenylhydrazine (2,4-DNPH)-coated silicagel tubes. Four levels of formaldehyde concentration were tested for storage stability at room temperature and at 4℃ over three months. Analytical proficiency testing was performed with four or 36 institutes. Results: Formaldehyde sample tubes were easily made through the injection of standard solutions and the average efficiencies of recovery were 95-101%. The coefficients of variation (CV) of the formaldehyde samples were 1.39-2.55%. The recovery efficiencies fell between 90% and 110% at the concentration range of 1-10 ㎍/sample over three months storage at refrigerated and room temperature. The CVs were less than 5% in the proficiency analytical testing. By adjusted proficient ranges, 64% of the results of the second proficiency analytical testing were acceptable. Conclusions: The formaldehyde samples made by injection on 2,4-DNPH-coated silicagel tubes were stable and applicable for quality control.

Interlaboratory Study for Proficiency Testing on the Water Toxicity Determinations by Acute Toxicity Test with Daphnia magna (국내 생태독성 분석기관에 대한 숙련도시험 결과 평가)

  • Kim, Jongmin;Shin, Kisik;Yu, Soonju;Kim, Myeong Ock;Choe, Sung Hun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.632-637
    • /
    • 2014
  • Proficiency testing by interlaboratory comparisons is used to determine the performance of individual laboratories. In order to verify the quality of acute toxicity testing with Daphnia magna, National Institute of Environmental Research in South Korea is regularly organizing interlaboratory comparisons to estimate the analytical accuracy of different laboratories. Total 58 laboratories located in South Korea took part in interlaboratory proficiency testing scheme with three proficiency testing samples. TU(Toxic Unit) values of each laboratory were determined and robust z-score was calculated in order to evaluate the proficiency levels. Based on the robust z-score classification, 74% of the participant laboratories showed a satisfactory performance (43 laboratories). The main reason of 'unsatisfactory' performance seemed to be considered that the unsuitable management of test organism incubation system and the lack of experience on the identification of the test organism condition by effect of toxicity.

Establishment of National Quality Control System for Analytical Laboratory of Pesticide Products by Proficiency Testing (농약 이화학시험 분석기관의 숙련도시험을 통한 정도관리체계 확립 연구)

  • Chang, Hee-Ra;Park, Hyo-Kyung;Lim, Youngjoo;Kim, Kwang-Ho;Kim, Chan Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.350-356
    • /
    • 2012
  • Performance of proficiency testing and the validation of analytical method was included a scheme of quality assurance in analytical chemistry laboratory to monitor a laboratory's performance abilities and produce consistently reliable data. This study was assessed the applicability of proficiency testing scheme proposed for analytical laboratories of pesticide product in domestic. The validation of analytical methods, stability and homogeneity for formulated pesticide products (emulsifiable concentrate) of emamectin benzoate and lufenuron was confirmed for the proficiency testing. The z-score of 33 participation laboratories for emamectin benzoate were that the numbers of outlier were 2 laboratories (6.0%), z-score outside the range from -3 to 3 designated "unaccptable" were 2 laboratories and z-score in the ranges -2 to -3 and 2 to 3 designated "questionable" were 3 laboratories (9.0%). Three laboratories (9.0%) showed the z-score designated "questionable" for lufenuron. The additional proficiency testing for various product types will be needed to establish the scheme of quality control.

Development of Asbestos Quality Control Sample for Proficiency Analytical Testing 1 - Development of Manufacturing Apparatus and Sample Preparing Procedure for Asbestos Quality Control Sample - (석면분석 정도관리용 표준시료 개발연구 I - 석면분석 정도관리용 표준시료 제조장치 개발 및 시료제조 방법 확립 -)

  • Yi, Gwang Yong;Lee, Jong- Han;Jung, Sijeong;Park, Doo Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.81-87
    • /
    • 2009
  • Final purpose of this study was designed to develop the quality control(QC) sample for proficiency analytical testing of asbestos. This study consisted of two parts; first, development of manufacturing apparatus and sample preparing procedure for asbestos quality control(QC) sample: second, validation of the QC samples made by our developed method as asbestos proficiency analytical testing sample. The main results of the first part research are as followed We developed the apparatus for manufacturing the asbestos QC sample, consisted of filter hold, filter holder manifolder, vacuum system, and vacuum pump. The most proper filter of making the QC samples was a cellulose ester membrane filter with 25 mm diameter, pore size 0.8 um. And we presented the optimal procedure for preparing the asbestos QC sample by using the developed apparatus. We will verify the manufactured asbestos QC samples by this method, and present the validation results to confirm the reliability as a asbestos QC sample in next paper.

Proficiency Test for Anions and Metal Ions in Aqueous Solution (수용액중 음이온 및 금속에 대한 숙련도 시험)

  • 이종해
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.69-77
    • /
    • 2000
  • This paper summerizes the results of the first proficiency testing program for achieving the analytical quality assurance of anions and metal ions in air borne particles in Korea. This program covered the chemical testing of anions(Cl-, NO3-, SO42-) and metals(Fe, Pb, Zn) in qeueous solution. The exercies was conducted by the Measurement & Analysis Committee of Korean Society for Atmospheric Environment(KOSAE). Pilot lab. was Division of Chemical Metrology and Materais Evaluation in Korea Research Institute of Standards and Science(KRISS). A total of 11 laboratories participated in the program. Two samples of 100mL in low density polyehylene bottles were supplied to participating laboratories. The proficiency testing results were interpreted by two graphical methods, Youden polt and x-Charts(control chart).

  • PDF

Evaluation of the proficiency testing results using river water-based reference materials for heavy metal analysis (중금속분석용 하천수 매질표준물질을 이용한 숙련도 결과 평가)

  • Song, Ko-Bong;Kim, Young-Hee;Shin, Sun-Kyoung;Lee, Su-Yeong;Kim, Hyun-Jung;Kang, Hak-Gu;Kim, Il-Gyu;An, Hee-Ju
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.284-294
    • /
    • 2010
  • In this study, river water-based reference materials (RMs), NIER-I08RW and NIER-I09, for trace metal analysis were prepared and certified for Pb, Cd, Cr and Cu with evaluation of uncertainties. The RMs were confirmed to be homogeneous enough to be used as proficiency testing materials since within-bottle homogenieties of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The RMs were distributed to environmental testing laboratories for the proficiency testing and the variation of Z scores of the proficiency testing results were compared for different assigned values. The relative bias, $B_{relative}$, deviations between reference values and consensus values, were lower than ${\pm}$1 except for cadmium of NIERI08RW. The results showed both values were in a good agreement and only 2.9% of Z scores changed by using a different assigned values such as consensus and reference values.

Quality Control System for Analytical Chemistry Laboratory of Pesticide Products (농약 이화학시험 분석기관 정도관리체계)

  • Chang, Hee-Ra;Lee, Joon-Yeob;Lee, Young-Ju;Kang, Hye-Rim;Kim, Chan-Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.529-544
    • /
    • 2011
  • Many international organizations, such as the International Organization for Standardization (ISO) and Collaborative International Pesticide Analytical Council (CIPAC), have published a guide to quality control requirements, proficiency testing and method validation for pesticide formulation. In general, proficiency testing is to determine the performance of individual laboratories from the comparison of test results and to monitor a laboratory's performance abilities. One of quality assurance (QA) scheme would be include the validation of analytical method that implies a performance characteristics, specificity, selectivity, linearity and so on. According to many international organizations, the quantification methods of active substance in formulated pesticide products are required to be reproducible, accurate and precise. This study was conducted to compare the international guidelines for the quality control, proficiency testing and method validation of analytical laboratories and to propose a general guidance for the establishment of quality control system in the analytical chemistry laboratories of pesticide formulation in domestic.

Evaluation of the proficiency testing results for brominated flame retardants in high impact polystyrene (고충격폴리스티렌 중 브롬계 난연제 숙련도시험 결과 평가)

  • Kim, Dal-Ho;Ryu, Je-Hoon;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.435-442
    • /
    • 2011
  • Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) which have taken much interest recently due to their potential hazardous effects to human body and ecosystem. Many countries and European community prohibits the usage of certain BFRs in electronics and electronic devices (e.g. RoHS). In this perspectives, Korea Research Institute of Standards and Science (KRISS) has designed and practiced proficiency testing programs based on the ISO/IEC 17043 in order to assist laboratory accreditation activities. The programs for interlaboratory comparisons include congeners of PBDE (PBDE-154, 183, 206, 209) in high impact polystyrene (HIPS). A sample bottle that contains 10 g granular HIPS was distributed to 35 participating laboratories and the test results were calculated by the statistical procedure using z-scores to evaluate performance of each laboratory. The results and the laboratory's performance were discussed.