• Title/Summary/Keyword: production efficiency.

Search Result 4,722, Processing Time 0.025 seconds

A Study on Medium-Sized Enterprises of Japan (일본의 중견기업에 관한 연구 : 현황과 특징, 정책을 중심으로)

  • Kang, Cheol Gu;Kim, Hyun Sung;Kim, Hyun Chul
    • Korean small business review
    • /
    • v.32 no.2
    • /
    • pp.209-223
    • /
    • 2010
  • Korea's business is composed of a few large-sized enterprises (which can be abbreviated as LSE) and a majority of small-sized enterprises (SSE). Although there has been a growing recognition of the need for the development of medium-sized enterprises (MSE) which can serve as a link between SSE and LSE, as yet there has not yet been a consensus on the definition, characteristics and the function of the MSE in Korea. Nowadays, the world is being globalized, and Japan and China are in competition to ne a great economic power. While East Asia is experiencing rapid changes, promoting MSE which can secure flexibility and efficiency through covering up the limitation of LSE and SSE is needed in order to respond the global market which is being specialized. The features of MSE in Japan can be listed as follows. First, the MSE in Japan is developing the company through getting into niche markets which are hard for major companies to enter rather than developing markets in order to compete against major companies directly. While MSEs are endeavoring to build the business firmly in the domestic market, they can possess special and competitive technical skills through trials and errors; so that they can get a chance develop their business through independent business system rather than putting their effort to compete against major companies. Second, from the MSEs with competitive edge in the market, there are many contributions to the national exportation. Those MSEs produce in domestic and maintain the quality of high price products which need cutting-edge technology, while they relocate the low and middle priced goods to the country where manufacturing costs are low, so that they can maintain the price competitiveness. Third, the industrial structure in Japan is formed from dual structure between major companies and small sized companies. In other words, in Japan's industrial structure which are composed of subcontract structure, this dual structure has taken a major role of small sized companies' growth and manufacturing businesses' international competitive power. Forth, MSE in Japan adopt a strategy of putting their value on qualitative scale growth rather than quantitative scale growth. In this paper, the case of Japanese MSE is analyzed. Along with its long history of Industrialization, Japan has a corporate environment where the SSEs can develop as a MSE and later a LSE through a full-support system. Among its SSEs, there are a number of world class corporations equipped with a large domestic market, win-win cooperation with the LSEs and an independent technology development. It can also be observed that these SSEs develop into MSEs with sustainable growth potentials. This study will focus on the condition under which the MSEs of Japan have been developed, and how they have survived the competition between SSEs and LSEs. Through this study, this paper attempts to offer solutions to Korea's polarization between the SSE and LSE, while providing the basis for SSEs revitalization. In general, if both extremities phenomenon deepen between LSE and SSE, there are possible fears of occurring disutility in national economy by the monopolization of LSE. For that reason, enterprise group, which can make SSE or MSE compete LSE in some area and ease the monopoly and oligopoly problem, is needed. This awareness has been shared for ages long. Nevertheless, there is no legal definition for MSE in Japan, and there is no definition about the enterprise size or unified view of MSE between scholars, but it is defined differently by each of academical person or research institution and study meeting. For that reason, this paper will organize the definition of MSE in Japan, and then will propose the characteristics of the background which has made MSE secure competitiveness and sustainable growth in global market. This study focus on that because through this process, the positive change to the awareness of MSE can be proposed in Korea and to seek the policy direction for building institutional framework which can make SSE become MES. Through this way, the fundamentals for SSE to become MSE can be managed and some appropriate suggestions which will be able to make MSE enter the global market in the future can also be proposed. Due to these facts, this study is very important and well timed task. In a sense of this way, this study will examine the definition and role of MSE in Japan. after this examination, this study will deal with the status, special feature, and promotion policy for MSE. Through this analysis of MSE in Japan, the foundation which be able to set the desirable role model for MSE in Korea can be proposed. Also, the political implication which is needed to push ahead to contribute to creating employment and economic growth through sustainable growth of MSEs in economic system of Korea can be offered through this study. It has been found that Japan's MSE functions as an indispensable link among various industrial structures by holding a significant position in employment rate, production and value added. Although the MSEs took up less than 1% of the entire number of businesses with 2700 manufacturing firms and 7000 non-manufacturing firms, its employment ratios are about 15%, while taking about 25% of the manufacturing industry's exports. In industries such as machinery and electronics which is considered Japan's major industry, the MSEs showed a higher than average ratio of manufacturing exports and employment rate. It can be analyzed that behind Japan's advantageous industries, close and deeply knit MSEs exist. Although there are no clearly stated policies geared towards the MSEs by the Japanese government, various political measures exist such as the R&D Project and the inducement of cooperation between enterprises which gives room for MSEs to participate in the SSE policies. In relation to these findings, the following practical measures can be considered in order to revitalize Korea's MSEs: First, there is a need for a legal definition of MSE and the incentives to provide legal support for its growth. Second, if a law to support the MSEs is established, it could provide a powerful inducement for the SSE to grow as a MSE, rather than stay as a SSE. Third, there is a need for a strategy of MSEs to establish a stable base in the domestic market and then advance to the global market with the accumulated trial and error and competitiveness. Fourth, the SSE themselves need the spirit of entrepreneurship in order to make the leap to a MSE. Because if nothing is to be changed about the system on the firms that grew, and the parts of the past custom was left to be managed alone, confusion and absence of management can take place. No matter how much tax favors the government will give and no matter how much incentive there could be through the policies, there are limits for industries to higher the ability to propagate. And because of that it is a period where industries need their own innovative skills to reform their firms.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF