• Title/Summary/Keyword: processing velocity

Search Result 873, Processing Time 0.022 seconds

A Study on the U-bending of Rectangular Hollow Tube by the Eccentric Extrusion and Bending Process (편심압출굽힘가공법에 의한 사각형 단면을 가진 중공 튜브제품의 U형굽힘가공에 관한 연구)

  • Kim, Jin-Hoon;Jin, In-Tai
    • Transactions of Materials Processing
    • /
    • v.7 no.5
    • /
    • pp.496-504
    • /
    • 1998
  • The eccentric extrusion and bending process for the forming of the curved rectangular hollow tube is newly developed. Generally the bending process of hollow tube is the secondary process followed by the extrusion process of the hollow tube from the round billet. So many defects such as wrinkling and the difference of wall thickness can be happened during the secondary bending process. In order to avoid the defects the new process named as "the eccentric extrusion and bending process" is suggested and applied to the U-bending of rectangular hollow tube. In this paper the kinematically admissible velocity field between the dies surface and the internal plug boundary surface s developed for the curving velocity. By the using of this curving velocity field the curvature of extruded products can be calculated with the parameters such as eccentricity dies length friction constant aspect ratio.

  • PDF

Investigation of the Final-Stage Forward Extrusion of Regular Polygonal-Shaped Bars From Circular Billets Using Square Die (평금형을 이용한 원형 소재에서 다각형바의 최종단계 전방압출에 관한 연구)

  • 김동권;조종래;배원병
    • Transactions of Materials Processing
    • /
    • v.4 no.1
    • /
    • pp.59-69
    • /
    • 1995
  • A simple kinematically admissible velocity field is proposed to determine the final-stage extrusion load and the average extruded length in the square-die forward extrusion of regular polygonal-shaped bars from circular billets. From the proposed velocity field, the upper-bound extrusion load and the average extruded length are determined by minimizing the total power consumption with respect to four parameters. Experiments have been carried out with hard solder billets at room temperature. The theoretical predictions of the extrusion load are in good agreements with the experimental results and there is generally reason able agreement in average extruded length between theory and experiment.

  • PDF

A Study on the Drawing of Strip by Upper Bound Elemental Technique (상계요소법에 의한 판재 인발공정에 관한 연구)

  • Hur, K.D.;Choi, Y.;Choi, I.K.
    • Transactions of Materials Processing
    • /
    • v.12 no.1
    • /
    • pp.11-17
    • /
    • 2003
  • For metal forming analysis, upper-bound solution is a practical method because the solution is overestimated. However it is not easy to determine the stresses on dies by using upper-bound solution. In this study, new scheme to calculate the stresses on dies based on upper bound solution is proposed. In the velocity fields, imaginary velocity is adapted to analyze the normal pressure on die surfaces. To verify the proposed scheme. plane strain drawing has been considered. The stresses on dies obtained by the proposed scheme are compared with the results of rigid plastic FEM and the experimental results. In the experiments, pressure film is used to measure the normal pressure on dies.

Digital image processing techniques of digital holographic PTV measurement (디지털 holographic PTV 측정을 위한 디지털 영상처리기법에 관한 연구)

  • Kim, Seok;Lee, Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.1-5
    • /
    • 2005
  • The digital HPTV velocity field measurement consists of four steps: recording, numerical reconstruction, particle extraction and velocity extraction. In the velocity extraction process, we improved PTV algorithm to extract the displacement of particle each placed in 3D space. Because a digital recording device was used, some factors such as a spatial resolution, numerical aperture, and particle concentration can affect the performance of the digital HPTV. Especially, a particle concentration ($C_{o}$) affected tile reconstruction efficiency in numerical reconstruction and particle extraction process. In this paper, the reconstruction efficiency was analyzed experimentally with different particle concentration. Optimal reconstruction efficiency was shown in the range of $C_{o}$=$13\∼15$ particles/$mm^{3}$.

  • PDF

Measurement of Distance and Velocity of Moving Objects using Single Camera Pseudo-Stereo Images

  • Lee, Jae-Soo;Kim, Soo-In;Choi, In-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.9
    • /
    • pp.32-38
    • /
    • 2007
  • In this study, a new algorithm for measuring the velocity and distance from a camera to a moving object by using pseudo-stereo images obtained from a single camera with a stereo adapter is proposed. The proposed system is similar to a parallel visual stereo system using a two-camera system, but because this system can obtain pseudo-stereo images form a single camera, it has advantages not only in the aspect of cost but also in stereo conformity by arrangement and the calibration of the left and right stereo cameras upon image processing.

Velocity feedback for controlling vertical vibrations of pedestrian-bridge crossing. Practical guidelines

  • Wang, Xidong;Pereira, Emiliano;Diaz, Ivan M.;Garcia-Palacios, Jaime H.
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.95-103
    • /
    • 2018
  • Active vibration control via inertial mass actuators has been shown as an effective tool to significantly reduce human-induced vertical vibrations, allowing structures to satisfy vibration serviceability limits. However, a lot of practical obstacles have to be solved before experimental implementations. This has motivated simple control techniques, such as direct velocity feedback control (DVFC), which is implemented in practice by integrating the signal of an accelerometer with a band-pass filter working as a lossy integrator. This work provides practical guidelines for the tuning of DVFC considering the damping performance, inertial mass actuator limitations, such as stroke and force saturation, as well as the stability margins of the closed-loop system. Experimental results on a full scale steel-concrete composite structure (behaves similar to a footbridge) with adjustable span are reported to illustrate the main conclusions of this work.

Development of Portable Arrhythmia Moniter Using Microcomputer(I) (마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로-)

  • 이명호;안재봉
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

Solidification Characteristics of Al-Cu Polycrystalline Ribbons in Planar Flow Casting (PFC법에 있어서의 Al-Cu 다결정리본의 응고특성)

  • Lee, Kyung-Ku;Lee, Sang-Mok;Hong, Chun-Ryo
    • Journal of Korea Foundry Society
    • /
    • v.15 no.4
    • /
    • pp.408-415
    • /
    • 1995
  • Polycrystalline Al-Cu ribbons were produced by planar flow casting(PFC). Solidification behavior and microstructual changes of the ribbons have been investigated as a function of ribbon thickness and processing parameters. The solidification front velocity, V varies within the ribbon, decreasing with increasing the distance, S from the wheel-contact surface, as $V=17.6S^{-1}$. In Al-4.5wt%Cu alloy, rapid decrease in solidification velocity toward the free surface causes a change in solidification morphology from planar to cellular, and finally, to dendritic. The length and inclination of columnar grains solidified with planar front were related to the wheel velocity. The transition from particulate degenerate eutectic structure to regular lamellar eutectic structure was observed to be caused by a difference of the relative growth velocites of ${\alpha}-Al$ and ${\theta}$ during solidification in the Al-Cu eutectic alloy.

  • PDF

The Detection of moving object by real time processing of dynamic image. (동영상 실시간 처리에 의한 이동물체 검출)

  • Kim, Y.H.;Lee, M.K.;Lee, J.S.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1383-1386
    • /
    • 1987
  • This paper concerns, the method for velocity of dynamic Image on two dimensional sequence Image which can be obtained from two sample lines on the street. The velocity of a single moving object Is measured by the number of total frame which Is required when an automobile passes over the second sample line through the first sample line. The measured results show that the velocity error Is less than 5% comparing with the value measured by X-band speed gun.

  • PDF

Physical Modeling of Process Parameters for Aluminum-Foam Generation (물리적 모델링을 이용한 알루미늄 발포공정 영향 인자 해석)

  • 옥성민;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.7
    • /
    • pp.558-564
    • /
    • 2001
  • An experimental modeling is applied to investigate the formation of forms in molten aluminum By using a specially designed equipment, the effect of process variables, such as the shape of stirrer, stirring velocity and fluid viscosity, on the formation of foams were studied in the glycerine added water. Bubbles formed in water had various diameter from 1 to 10 mm and the number of bubbles was 0 to 20/$cm^2$. It turned out that among various variables the stirring velocity and fluid viscosity played important roles on the formation of bubbles. The results obtained from the model experiment were preyed to be convincible also in the real aluminum foam.

  • PDF