• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.036 seconds

Development of a precision machining process for the outer cylinder of vacuum roll for film transfer (필름 이송을 위한 진공 롤 외통의 정밀가공 공정개발)

  • Eui-Jung Kim;Ho-Sang Lee
    • Design & Manufacturing
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2024
  • Unlike the roll-to-roll process that uses a steel roll and a nip roll, a vacuum roll can hold and transfer a thin film using a single roll. To precisely manufacture a vacuum roll, a thin outer cylinder must be machined, which is assembled on the outside of the roll and contacts the film via vacuum pressure. In this study, the effects of jaw width and chucking force on the deformation of the outer cylinder during the turning process were investigated using analysis, and a precision machining and burr removal process was developed. The deformation of the outer cylinder decreased almost linearly with increasing jaw width and increased with higher chucking force and larger cylinder diameter. Additionally, the deflection due to the weight of the outer cylinder was approximately three times greater than that caused by film tension. For the machined outer cylinder, a burr removal experiment was conducted, and concentricity and cylindricity were measured. Using a device that removes burrs by rotating a wheel connected to the main shaft at high speed, it was found that burrs generated on the inner diameter could be removed very efficiently. On the vacuum side, the concentricity errors of the inner and outer diameters were 0.015 mm and 0.014 mm, respectively, and on the opposite side, they were 0.006 mm and 0.010 mm, respectively. Additionally, the measurement of Total Indicator Runout (TIR) according to the angle showed that the maximum cylindricity of the outer and inner diameters was 0.02 mm and 0.025 mm, respectively. Finally, through burr-height measurement at the hole boundary, it was found that the heights were within 0.05 mm.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Efficient Similarity Measurement Technique of Windows Software using Dynamic Birthmark based on API (API 기반 동적 버스마크를 이용한 윈도우용 소프트웨어의 효율적인 유사도 측정 기법)

  • Park, Daeshin;Jie, Hyunho;Park, Youngsu;Hong, JiMan
    • Smart Media Journal
    • /
    • v.4 no.2
    • /
    • pp.34-45
    • /
    • 2015
  • The illegal copy of Windows software is one of the problems, because Windows is the most popular operating system in the country. The illegal copy can be infringe a software copyright, and software birthmark is one of solutions which is protecting software copyright. Software birthmark is a technique to distinguish software piracy using feature information from software. The type of software birthmark can be differentiated between static birthmark and dynamic birthmark through an extraction method. Static birthmark and dynamic birthmark have strengths and weaknesses. In this paper, we propose similarity measurement technique using dynamic birthmark based on API, and we explain extraction process of dynamic birthmark. In addition, we have verified that the proposed similarity measurement technique meet resilience and credibility through experiment. Furthermore, we saw that proposed measurement technique better than existing measurement technique.

Study on The Estimation Method of the Joint for the Operation of the Upper Limb Rehabilitation Equipment for Hemiplegic Patients II (편마비 환자의 상지 재활 기기 운용을 위한 관절 각 추정 기법에 관한 연구 II)

  • Song, K.S.;Eom, S.H.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.4
    • /
    • pp.313-318
    • /
    • 2014
  • In this paper, we propose a method for correcting the measurement axis twist that occurs in the process of wearing and each estimation method of joint in which the inertial measurement unit based in health arm by the method of operation upper limb rehabilitation equipment of hemiplegic patients. In order to verify the proposed method, it is fitted with a inertial measurement unit of the upper arm and forearm of the experimenter left arm, verified by comparing actual joint angle is detected by photographing the arbitrary posture, the angle that the estimated joint. Then, it was verified by comparing the applied front / rear techniques for correcting the measurement axis twist. A result of the experiment, before applying the measurement axis twist correction, joint, after but each match rate showed a weak concordance rate in 89.16% and were corrected, measurement axis twist, each concordance rate of joint agreement of 93.28% I understand that it has been 4.12% improvement in the rate.

  • PDF

Intra- and Inter-rater Reliabilities of Infrasternal Angle Measurement

  • Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.3
    • /
    • pp.154-158
    • /
    • 2015
  • Purpose: The purpose of this study was to propose a new reference point for measurement of the infrasternal angle and to investigate the intra- and inter-rater reliabilities of infrasternal angle measurement using photographs. Methods: Twenty-four healthy male college students participated as subjects in this study. Photographs were taken of subjects in two postures, one standing with the shoulders relaxed and one standing with the shoulders at $150^{\circ}$ abduction. All photographs were analyzed using Image J software. Raters used the photographs to measure the infrasternal angle between the xiphoid process, the medial margin of rib and navel on the right and left sides. The reliability of the infrasternal angle measurement was assessed by means of intraclass correlation coefficients [ICC (3,1)]. The level of statistical significance was set at p<0.05. Results: The intra- and inter-rater reliabilities of the infrasternal angle measurement for the right side at rest were excellent (ICC=0.866 and 0.813, respectively), as were those for the left side at rest (ICC=0.919 and 0.846, respectively). At $150^{\circ}$ shoulder abduction, the intra- and inter-rater reliabilities for measurement of the infrasternal angle on the right side were excellent (ICC=0.972 and 0.778, respectively), as were those for the left side (ICC=0.914 and 0.826, respectively). Conclusion: These findings suggest that this technique can be successfully used to measure the infrasternal angle, thus suggesting a new reference point for determining the length of the internal oblique and external oblique muscles in clinical situations.

A Study on the Statistical Method for the Target Component of a Glucose-lowering Functional Material in Extracts of Evening Primerose Seeds (혈당상승억제 기능성 소재인 달맞이꽃종자 추출물의 지표물질 분석법의 통계적 검증에 대한 연구)

  • Park, Sang-Wook;Bang, Joon Seok;Lee, Wonjae
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.1
    • /
    • pp.70-76
    • /
    • 2016
  • Background: The use of the extracts from evening primrose seeds as a health functional food has been gradually increased. Therefore, the monitoring and screening process has been considerably required for its quality control. Objective: This study aimed to estimate the measurement uncertainty associated with determination of penta-o-galloyl ${\beta}$-D-glucose (PGG) in extracts from evening primrose seeds by high-performance liquid chromatography. Methods: The sources of measurement uncertainty was expressed in accordance with mathematical/statistical theories of GUM & EURACHEM Guide. The expanded uncertainty was calculated by using the relative standard uncertainty between analytical result and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). Results: In the results of 95% confidence interval, the uncertainty in measurement was $10,253.34{\pm}1,844.50{\mu}g/kg$ (k = 2.0). Conclusion: In this study, it showed that the value of uncertainty in measurement for determination of PGG in extracts from evening primrose seeds by HPLC has about 18.0% influence on PGG contents of the analytical results. The results would be very useful for the monitoring and screening of evening primrose seeds marketed in Korea for its quality control as dietary supplement.

A Study on the Quantitative Interoperability Measurement Methodology of System of Systems (복합체계의 정량적 상호운용성 평가 방법론 연구)

  • Kim, Jinsung;Jeong, Chanki
    • Journal of Information Technology and Architecture
    • /
    • v.9 no.2
    • /
    • pp.167-176
    • /
    • 2012
  • In Korean military measuring systems interoperability is based on LISI (Level of Information System Interoperability) model at the requirement generation and acquisition process. However, LISI model cannot be used for interoperability measurement of system of systems (SoS) because LISI model is focused on interoperability measurement of a given system or system pair. Also, LISI model cannot provide quantitative information for interoperability decision because of qualitative rather than quantitative approach. This paper proposes a quantitative interoperability measurement methodology of SoS. At the proposed methodology, mission threads and supporting systems are identified using architecture approach, and Interoperability of SoS is measured with systems multiplicity and resemblance coefficient. Finally, a case study is presented to show the usefulness of the methodology.

Review on Floating Pulse and Sinking Pulse in the View Point of Tonometric Measurement (토노메트리 측정 관점에서의 부침맥 고찰)

  • Lee, Jeon;Lee, Yu-Jung;Ryu, Hyun-Hee;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, floating pulse and sinking pulse are frequently used for diagnosis about where disease is located and how much severe they are. However, in what mechanism floating pulse and sinking pulse arise is not known well. There are two point of views on substantial of floating pulse and sinking pulse. The first one is the floating and sinking degrees is the expression on the depth of pulsation. And, the second one is floating and sinking pulse is based on the response of pulsation to the indent pressure on radial artery. In this paper, we discussed these two opinions in the view point of tonometric measurement. The process for diagnosis on floating pulse and sinking pulse is similar to the tonometric measurement for non invasive blood pressure or intraocular pressure. We modelled the degrees of depth of pulsation with different indent pressures for initial pulsation feeling and different slopes of indent pressure lines. From this modelling, we can confirm the effect of pulsation depth on P-H curve, that is, in the model where lower pulsation is assumed, the shift of optimal indent pressure to the right was observed. The response of pulse pressure to the indent pressure was tried to be modelled with the degrees of mean blood pressure. Consequently, we tried to model the phenomenon of floating and sinking pulse for the first. And, from this modelling, we can get abundant understanding on how floating and sinking pulse can be caused. In the further study, we want to prove the suitability of this tonometric measurement based modelling with various studies including ultrasound measurement for the depth of pulsation in different EMI subjects.

  • PDF

Measurement of Primary-mirror Vertex Coordinates for a Space Camera by Using a Computer-generated Hologram and a Theodolite (컴퓨터 제작 홀로그램과 데오도라이트를 이용한 인공위성 카메라 주 반사경의 정점 좌표 측정)

  • Kang, Hye-Eun;Song, Jae-Bong;Yang, Ho-soon;Kihm, Hagyong
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.146-152
    • /
    • 2017
  • Alignment of the mirrors composing a space telescope is an important process for obtaining high optical resolution and performance of the camera system. The alignment of mirrors using cube mirrors requires a relative coordinate mapping between the mirror and the cube mirror before optical-system integration. Therefore, to align the spacecraft camera mirrors, the relative coordinates of the vertex of each mirror and the corresponding cube mirror must be accurately measured. This paper proposes a new method for finding the vertex position of a primary mirror, by using an optical fiber and alignment segments of a computer-generated hologram (CGH). The measurement system is composed of an optical testing interferometer and a multimode optical fiber. We used two theodolites to measure the relative coordinates of the optical fiber located at the mirror vertex with respect to the cube mirror, and achieved a measurement precision of better than $25{\mu}m$.

Improvement of Reliability of Static Execution Time Analysis Using Software Monitoring Technique (소프트웨어 감시 기법을 활용한 정적 실행시간 분석의 신뢰성 향상)

  • Kim, Yun-Kwan;Kim, Tae-Wan;Chang, Chun-Hyon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.37-45
    • /
    • 2010
  • A system which needs timely accuracy has to design and to verify correctly about execution-time for reliability. Accordingly, it is necessary for timing analysis tools, and much previous research worked. In timing analysis tool, there are two methods. One is a static analysis, and the other is a measurement based analysis. A static analysis is able to spend time less than a measurement based analysis method, but has low reliability of analysis result caused by hard to estimate time of I/O caused by various hardware. A measurement based analysis can be close analysis to real result, but it is hard to adapt to actual application, and spend a lot of time to get result of analysis. As such, this paper present a software monitoring architecture to supply reliability of static analysis process. In a presented architecture, it can select target as needed measurement through static analysis, and reuse result of measurement exist. Therefore, The architecture can reduce overload of time and performance for measurement, and improve the reliability which is the worst problem of static analysis.