• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.038 seconds

REAL - TIME ORBIT DETERMINATION OF LOW EARTH ORBIT SATELLITES USING RADAR SYSTEM AND SGP4 MODEL (RADAR 시스템과 SGP4 모델을 이용한 저궤도 위성의 실시간 궤도결정)

  • 이재광;이성섭;윤재철;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.1
    • /
    • pp.21-28
    • /
    • 2003
  • In case that we independently obtain orbital informations about the low earth satellites of foreign countries using radar systems, we develop the orbit determination algorithm for this purpose using a SGP4 model with an analytical orbit model and the extended Kalman filter with a real-time processing method. When the state vector is Keplerian orbital elements, singularity problems happen to compute partial derivative with respect to inclination and eccentricity orbit elements. To cope with this problem, we set state vector osculating to mean equinox and true equator cartesian elements with coordinate transformation. The state transition matrix and the covariance matrix are numerically computed using a SGP4 model. Observational measurements are the type of azimuth, elevation and range, filter process to each measurement in a lump. After analyzing performance of the developed orbit determination algorithm using TOPEX/POSEIDON POE(precision 0.bit Ephemeris), its position error has about 1 km. To be similar to performance of NORAD system that has up to 3km position accuracy during 7 days need to radar system performance that have accuracy within 0.1 degree for azimuth and elevation and 50m for range.

Photoelectric Properties of PbTe/CuPc Bilayer Thin Films (PbTe/CuPc 이층박막의 광전 특성)

  • Lee, Hea-Yeon;Kang, Young-Soo;Park, Jong-Man;Lee, Jong-Kyu;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The crystallized CuPc and PbTe films are formed by thermal evaporation and pulsed ArF excimer laser ablation. Structural and electrical properties of thin film is observed by XRD and current-voltage(I-V) curves. From XRD analysis, both PbTe and CuPc thin films show a-axis oriented structure. For the measurement of photovoltaic effect, the transverse current-voltage curve of CuPc/Si, PbTe/Si and PbTe/CuPc/Si junctions have been analyzed in the dark and under illumination. The PbTe/CuPc/Si junction exthibits a strong photovoltaic characteristics with short circuit current($J_{sc}$) of $25.46\;mA/cm^{2}$ and open-circuit voltage($V_{oc}$) of 170 mV. Quantum efficiency and power conversion efficiency are calculated to be 15.4% and $3.46{\times}10^{-2}$, respectively. Based on the results of QE and ${\eta}$, the photocurrent process of PbTe/CuPc/Si junction can be explained as following three effective steps; photocarrier generation in the CuPc layer, carrier separation at PbTe/CuPc interface, and finally a transportation of electrons through the PbTe layer.

  • PDF

Diagnostic Usefulness of Computed Tomography Compared to Conventional Chest X-Ray for Chest Trauma Patients (흉부 외상 환자에서 일반흉부촬영과 비교한 흉부단층촬영의 진단적 유용성)

  • Choi, Kyu Ill;Seo, Kang Suk;Ryoo, Hyun Wook;Park, Jung Bae;Chung, Jae Myung;Ahn, Jae Yoon;Kang, Seong Won;Yi, Jae Hyuck
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.142-147
    • /
    • 2009
  • Purpose: Early diagnosis and management of therapeutic interventions are very important in chest trauma. Conventional chest X-rays (CXR) and computed tomography (CT) are the diagnostic tools that can be quickly implemented for chest trauma patients in the emergency department. In this study, the usefulness of the CT as a diagnostic measurement was examined by analyzing the ability to detect thoracic injuries in trauma patients who had visited the emergency department and undergone CXR and CT. Methods: This study involved 84 patients who had visited the emergency department due to chest trauma and who had undergone both CXR and CT during their diagnostic process. The patients' characteristics and early vital signs were examined through a retrospective analysis of their medical records, and the CXR and the CT saved in the Picture Archiving Communication System (PACS) were examined by a radiologist and an emergency physician to verify whether or not a lesion was present. Results: Pneumothoraxes, hemothoraxes, pneumomediastina, pulmonary lacerations, rib fractures, vertebral fractures, chest wall contusions, and subcutaneous emphysema were prevalently found in a statistically meaningful way (p<0.05) on the CT. Even though their statistical significance couldn' be verified, other disorders, including aortic injury, were more prevalently found by CT than by CXR. Conclusion: CT implemented for chest trauma patients visiting the emergency department allowed disorders that couldn' be found on CXR to be verified, which helped us to could accurately evaluate patients.

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

Kinetic Measurement of the Step Size of DNA Unwinding by Bacteriophage T7 DNA Helicase gp4 (T7 박테리오파지 gp4 DNA helicase에 의한 DNA unwinding에서 step size의 반응속도론적 측정)

  • Kim, Dong-Eun
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.131-140
    • /
    • 2004
  • T7 bacteriophage gp4 is the replicative DNA helicase that unwinds double-stranded DNA by utilizing dTTP hydrolysis energy. The quaternary structure of the active form of T7 helicase is a hexameric ring with a central channel. Single-stranded DNA passes through the central channel of the hexameric ring as the helicase translocates $5'\rightarrow3'$ along the single-stranded DNA. The DNA unwinding was measured by rapid kinetic methods and showed a lag before the single-stranded DNA started to accumulate exponentially. This behavior was analyzed by a kinetic stepping model for the unwinding process. The observed lag phase increased as predicted by the model with increasing double-stranded DNA length. Trap DNA added in the reaction had no effect on the amplitudes of double-stranded DNA unwound, indicating that the $\tau7$ helicase is a highly processive helicase. Global fitting of the kinetic data to the stepping model provided a kinetic step size of 10-11 bp/step with a rate of $3.7 s^{-1}$ per step. Both the mechanism of DNA unwinding and dTTP hydrolysis and the coupling between the two are unaffected by temperature from $4∼37^{\circ}C$. Thus, the kinetic stepping for dsDNA unwinding is an inherent property of tile replicative DNA helicase.

A Study on the Adsorption Characteristic of Cobalt on ZrO2 in High-Temperature Water (고온수중에서 ZrO2의 코발트흡착 특성에 대한 연구)

  • Kim, Yu-Hwan;Bae, Seong-Youl
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.267-275
    • /
    • 1997
  • $ZrO_2$ Powder was Prepared by sol-gel process and the adsorption characteristic of cobalt($Co^{2+}$) by $ZrO_2$ adsorbent in high-temperature water was investigated using batch adsorption experiment with a stirred autoclave. The prepared $ZrO_2$ was calcined at $600{\sim}1400^{\circ}C$ and analyzed by X-ray diffractometry, SEM, BET surface area, FT-IR and TG-DTA measurement. The tetragonal Phase of $ZrO_2$ is produced $480^{\circ}C$ from amorphous gel at temperature $480^{\circ}C$. Both tetragonal and monoclinic phase of $ZrO_2$ exist at temperature between $600^{\circ}C$ and $1000^{\circ}C$. At temperature $1200^{\circ}C$, tetragonal to monoclinic phase trasition is occurred. The $Co^{2+}$ adsorption capacity of $ZrO_2$ calcined at $600^{\circ}C$ for 4 hours is 0.16 meq $Co^{2+}/g$ adsorbent in the high temperature at $250^{\circ}C$. The adsorption of $Co^{2+}$ on the $ZrO_2$ adsorbent is irreversible endothermic in the temperature range ($125-175^{\circ}C$). The standard enthalpy change (${\Delta}H^{\circ}$) of $ZrO_2$ calcined at $600^{\circ}C$ for 4 hours is 18 kJ/gmol.

  • PDF

Analysis on Pilot Survey for Cadastral Non-correspondence Arrangements (지적불부합지의 정리를 위한 실험측량 분석 연구)

  • 강태석;권규태
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.269-275
    • /
    • 2003
  • The cadastral system which accomplishes the base of national land administration with accuracy of proper data and the cadastral maintenance quickly is agreeing with the actual place in information ages in Inundation. But even in spite of many efforts, various Problems are exposed in accuracy of the data on the cadastral maps and local situation must agree accurately from the process which propels cadastral information systems. Therefore, it must be carried out the cadastral non correspondence arrangement first of all in link of the plan which it corrects the error of existing data and computerization quickly. It summarizes the research as follows ; Cadastral non correspondence of the land boundaries on the map and actual circumstance does not agree with cadastral maps accurately, The lands which exceed the standards with the position error excess of 50cm on lil ,200 and 240cm on 1/6,000 areas on the map scale are the registration correction objectives. It is investigated that the cadastral non correspondence parcels occur in various cause and long period, the area error corrections are mainly objectives, and about 80% of the test area comes to reveal within permitted the limit of the measurement of planimetric area for cadastral survey, so it is not difficult with the fact that the compensation back which it follows in area increase and decrease and the location error correction becomes the important object fer the cadastral non correspondence arrangement projects.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

Performance Evaluation of the Serially Connected Two Stage Fiber Filter for the RO Membrane Pre-treatment (2단 섬유여과 공정의 역삼투막 전처리 성능평가)

  • Bae, Si-Youl;Yun, Chang-Han;Kang, Dong-Hyo
    • Membrane Journal
    • /
    • v.19 no.2
    • /
    • pp.165-171
    • /
    • 2009
  • This study was for the evaluation of adaptability of the fiber filter as the pre-treatment of the RO membrane through SDI (Silt Density Index) measurement. The turbidity of raw waters were $0.76{\sim}1.6$ NTU for the effluent of sewer treatment plants (STP) and $2.2{\sim}3.3$ NTU for sea waters and 100 NTU for the surface water. The turbidity of the $2^{nd}$ filtrate of the serially connected two fiber filters was $0.07{\sim}0.25$ NTU and $SDI_{15}$ was $1.4{\sim}2.8$ when the 17% PAC was dosed $10{\sim}30ppm$. Results of the turbidity and $SDI_{15}$ of the $2^{nd}$ filtrate of the fiber filter which were compared with them of the lab scale MF/UF disc filter for the same STP's effluents showed that filtrate quality were enhanced with a little on the order of two stage fiber filter>MF>UF, the difference in $SDI_{15}$ was only $0.7{\sim}1.0$. So, the filtrate of the serially connected two stage fiber filter could satisfy $SDI_{15}$ 5.0 safely which was normally required for the feed water by the RO membrane supplier and it means the serially connected two stage fiber filter could be applied as the pre-treatment process of the RO membrane.

Literature Review of Key Success Factors of Management Innovation Actions in Domestic - Focused on Six Sigma, TQM, Lean Six Sigma, ERP, TPM, BPR, Project Management, System Engineering - (국내 경영혁신 활동의 핵심 성공요인 문헌 연구 - 6시그마, TQM, 린 6시그마, ERP, TPM, BPR, Project Management, System Engineering 중심으로 -)

  • Mun, JeOk;Yoon, SungPil
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.3
    • /
    • pp.639-648
    • /
    • 2016
  • Purpose: Existing precedent studies include success factors of individual management innovation activities constantly. However, those studies have limitations about the common key success factors of individual management innovation activities. Methods: For this study, we investigate the key success factors using literature research of the most typical management innovation activities adopted and implemented by many companies in Korea, such as 6sigma, TQM, Lean 6sigma, ERP, TPM, BPR, Project Management, System Engineering. Factors emerging repeatedly was combined into common factors and inherent factors that are necessary for the success of individual management innovation activities are designated to essential factors. Results: 'Essential factors for Six Sigma' consist of 5 items. Black belt operating system, personnel management system linkage, the correct management of the data, perform improvement projects associated with financial performance financial result, linked to financial performance improvement project, project progress management. 'Essential factors of TQM' are arranged 4 items. Quality team's independence and role, goal-setting, Quality Information System, corporate's philosophy of quality first. 'Essential factors of Lean Six Sigma' are the selection of value stream which is based on the customer needs and the value creation and identify the project based on the selected value in the company. 'Essential factors of ERP' are investigated 6 items. Ongoing system maintenance and upgrades, the measurement and support of user satisfaction, the operating systems and the policies for the maintenance, IT infrastructure, change adaption condition monitoring, focusing on improving business performance. 'Essential factors for TPM' are arranged 4 items. Motivated and energetic Bottom-Up, CEO's recognition of the importance facility management, long-term perspective of necessity and ongoing patience. 'Essential factors for BPR' are the pursuit of change process and the staff's sense of crisis management. 'Essential factors for Project Management' are the strategy that reduce the risk management skills through risk management and the understanding and organized management for the project participant's needs. 'Essential factors for System Engineering' consist of 2 items. The first is the design for the best balanced system with pre-analysis about the compromise the cost, schedule and the performance. The second is the analysis of large problem into small problems which can solved. We have found the solution considering components of the interface through the systematic perspective. Conclusion: Common factors and essential factors presented in this study will properly help to introduce the individual management innovation activities for the each business sector and implement management innovation. After this study, new literature research that reflect new studies should accomplish steadily.