• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.039 seconds

Evaluation of 3DVH Software for the Patient Dose Analysis in TomoTherapy (토모테라피 환자 치료 선량 분석을 위한 3DVH 프로그램 평가)

  • Song, Ju-Young;Kim, Yong-Hyeob;Jeong, Jae-Uk;Yoon, Mee Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.201-207
    • /
    • 2015
  • The new function of 3DVH software for dose calculation inside the patient undergoing TomoTherapy treatment by applying the measured data obtained by ArcCHECK was recently released. In this study, the dosimetric accuracy of 3DVH for the TomoTherapy DQA process was evaluated by the comparison of measured dose distribution with the dose calculated using 3DVH. The 2D diode detector array MapCHECK phantom was used for the TomoTherapy planning of virtual patient and for the measurement of the compared dose. The average pass rate of gamma evaluation between the measured dose in the MapCHECK phantom and the recalculated dose in 3DVH was $92.6{\pm}3.5%$, and the error was greater than the average pass rate, $99.0{\pm}1.2%$, in the gamma evaluation results with the dose calculated in TomoTherapy planning system. The error was also greater than that in the gamma evaluation results in the RapidArc analysis, which showed the average pass rate of $99.3{\pm}0.9%$. The evaluated accuracy of 3DVH software for TomoTherapy DQA process in this study seemed to have some uncertainty for the clinical use. It is recommended to perform a proper analysis before using the 3DVH software for dose recalculation of the patient in the TomoTherapy DQA process considering the initial application stage in clinical use.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Development of Analytic Hierarchy Process or Solving Dependence Relation between Multicriteria (다기준 평가항목간 중복도를 반영한 AHP 기법 개발)

  • 송기한;홍상연;정성봉;전경수
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.7
    • /
    • pp.15-22
    • /
    • 2002
  • Transportation project appraisal should be precise in order to increase the social welfare and efficiency, and it has been evaluated by only a single criterion analysis such as benefit/cost analysis. However, this method cannot assess some qualitative items, and cannot get a proper solution for the clash of interests among various groups. Therefore, the multi-criteria analysis, which can control these problems, is needed, and then Saaty has developed one of these methods, AHP(Analytic Hierarchy Process) method. In AHP, the project is evaluated through weighted score of the criteria and the alternatives, which is surveyed by a questionnaire of specialists. It is based on some strict suppositions such as reciprocal comparison, homogeneity, expectation, independence relationship between multi-criteria, but supposing that each criterion has independence relation with others is too difficult in two reasons. First, in real situation, there cannot be perfect independence relationship between standards. Second, individuals, even though they are specialists of that area, do not feel the degree of independence relation as same as others. This paper develops a modified AHP method for solving this dependence relationship between multi-criteria. First of all. in this method, the degree of dependence relationship between multi-criteria that the specialist feels is surveyed and included to the weighted score of multi-criteria This study supposes three methods to implement this idea. The first model products the degree of dependence relationship in the first step for calculating the weighted score, and the others adjust the result of weighted score from the basic AHP method to the dependence relationship. One of the second methods distributes the cross weighted score to each standard by constant ratio, and the other splits them using Fuzzy measure such as Bel and Pl. Finally, in order to validate these methods, this paper applies them to evaluate the alternatives which can control public resentments against Korean rail path in a city area.

Effect of the Degree of Weathering on the Distribution of Aggregate Particle Size and the Generation of Fine Rock Particles during Crushing of Granite (화강암 파쇄시 풍화정도가 골재 입도분포 및 미석분 발생에 미치는 영향)

  • You, Byoung-Woon;Lee, Jin-Young;Lee, Dong-kil;Cheong, Young-Wook
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.429-438
    • /
    • 2022
  • This study evaluated the effect of the degree of weathering on the particle size distribution and the amount of fine particles generated in the aggregate production process during the crushing of igneous rock. Rock samples were collected from three areas with differences in strength from the Schmith hammer measurement at the aggregate quarry in Geochang, Gyeongsangbuk-do. After crushing with a jaw crusher under the same conditions in laboratory, particle size analysis, mineral analysis, chemical analysis, and weathering index were calculated. The Schmidt hammer measurements were 56, 28, and <10, and the CIA and CIW values of weathering index were also different, so the rock samples were classified into hard rock, soft rock, and weathered rock according to the weathering degree. It shows a smaller particle size distribution toward weathered rocks under the microscope, and the proportion of altered clay minerals such as sericite increased. The composition of feldspar and quartz was high for hard rock, and the ratio of muscovite and kaolinite was low. As a result of the crushing of the jaw crusher, hard rock produced a lot of coarse crushed material (13.2mm), while soft rock and weathered rock produced fine crushed material (4.75mm). The former showed the characteristics of the beta distribution curve, and the latter showed the bimodal distribution curve. The production of fine rock particles (based on 0.71mm of sieve, wt. %) increased to 13%<21%<22% in hard rock, soft rock, and weathered rock, and the greater the degree of weathering, the more fine rock particles were generated. The fine particles are recovered by the operation of the sand unit in the wet aggregate production process. Therefore, in order to minimize the amount of sludge generated in the aggregate production process, it was judged that a study on the optimal operation of cyclones could be necessary.

The Effect of Mutual Trust on Relational Performance in Supplier-Buyer Relationships for Business Services Transactions (재상업복무교역중적매매관계중상호신임대관계적효적영향(在商业服务交易中的买卖关系中相互信任对关系绩效的影响))

  • Noh, Jeon-Pyo
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.4
    • /
    • pp.32-43
    • /
    • 2009
  • Trust has been studied extensively in psychology, economics, and sociology, and its importance has been emphasized not only in marketing, but also in business disciplines in general. Unlike past relationships between suppliers and buyers, which take considerable advantage of private networks and may involve unethical business practices, partnerships between suppliers and buyers are at the core of success for industrial marketing amid intense global competition in the 21st century. A high level of mutual cooperation occurs through an exchange relationship based on trust, which brings long-term benefits, competitive enhancements, and transaction cost reductions, among other benefits, for both buyers and suppliers. In spite of the important role of trust, existing studies in buy-supply situations overlook the role of trust and do not systematically analyze the effect of trust on relational performance. Consequently, an in-depth study that determines the relation of trust to the relational performance between buyers and suppliers of business services is absolutely needed. Business services in this study, which include those supporting the manufacturing industry, are drawing attention as the economic growth engine for the next generation. The Korean government has selected business services as a strategic area for the development of manufacturing sectors. Since the demands for opening business services markets are becoming fiercer, the competitiveness of the business service industry must be promoted now more than ever. The purpose of this study is to investigate the effect of the mutual trust between buyers and suppliers on relational performance. Specifically, this study proposed a theoretical model of trust-relational performance in the transactions of business services and empirically tested the hypotheses delineated from the framework. The study suggests strategic implications based on research findings. Empirical data were collected via multiple methods, including via telephone, mail, and in-person interviews. Sample companies were knowledge-based companies supplying and purchasing business services in Korea. The present study collected data on a dyadic basis. Each pair of sample companies includes a buying company and its corresponding supplying company. Mutual trust was traced for each pair of companies. This study proposes a model of trust-relational performance of buying-supplying for business services. The model consists of trust and its antecedents and consequences. The trust of buyers is classified into trust toward the supplying company and trust toward salespersons. Viewing trust both at the individual level and the organizational level is based on the research of Doney and Cannon (1997). Normally, buyers are the subject of trust, but this study supposes that suppliers are the subjects. Hence, it uniquely focused on the bilateral perspective of perceived risk. In other words, suppliers, like buyers, are the subject of trust since transactions are normally bilateral. From this point of view, suppliers' trust in buyers is as important as buyers' trust in suppliers. The suppliers' trust is influenced by the extent to which it trusts the buying companies and the buyers. This classification of trust using an individual level and an organization level is based on the suggestion of Doney and Cannon (1997). Trust affects the process of supplier selection, which works in a bilateral manner. Suppliers are actively involved in the supplier selection process, working very closely with buyers. In addition, the process is affected by the extent to which each party trusts its partners. The selection process consists of certain steps: recognition, information search, supplier selection, and performance evaluation. As a result of the process, both buyers and suppliers evaluate the performance and take corrective actions on the basis of such outcomes as tangible, intangible, and/or side effects. The measurement of trust used for the present study was developed on the basis of the studies of Mayer, Davis and Schoorman (1995) and Mayer and Davis (1999). Based on their recommendations, the three dimensions of trust used for the study include ability, benevolence, and integrity. The original questions were adjusted to the context of the transactions of business services. For example, a question such as "He/she has professional capabilities" has been changed to "The salesperson showed professional capabilities while we talked about our products." The measurement used for this study differs from those used in previous studies (Rotter 1967; Sullivan and Peterson 1982; Dwyer and Oh 1987). The measurements of the antecedents and consequences of trust used for this study were developed on the basis of Doney and Cannon (1997). The original questions were adjusted to the context of transactions in business services. In particular, questions were developed for both buyers and suppliers to address the following factors: reputation (integrity, customer care, good-will), market standing (company size, market share, positioning in the industry), willingness to customize (product, process, delivery), information sharing (proprietary information, private information), willingness to maintain relationships, perceived professionalism, authority empowerment, buyer-seller similarity, and contact frequency. As a consequential variable of trust, relational performance was measured. Relational performance is classified into tangible effects, intangible effects, and side effects. Tangible effects include financial performance; intangible effects include improvements in relations, network developing, and internal employee satisfaction; side effects include those not included either in the tangible or intangible effects. Three hundred fifty pairs of companies were contacted, and one hundred five pairs of companies responded. After deleting five company pairs because of incomplete responses, one hundred five pairs of companies were used for data analysis. The response ratio of the companies used for data analysis is 30% (105/350), which is above the average response ratio in industrial marketing research. As for the characteristics of the respondent companies, the majority of the companies operate service businesses for both buyers (85.4%) and suppliers (81.8%). The majority of buyers (76%) deal with consumer goods, while the majority of suppliers (70%) deal with industrial goods. This may imply that buyers process the incoming material, parts, and components to produce the finished consumer goods. As indicated by their report of the length of acquaintance with their partners, suppliers appear to have longer business relationships than do buyers. Hypothesis 1 tested the effects of buyer-supplier characteristics on trust. The salesperson's professionalism (t=2.070, p<0.05) and authority empowerment (t=2.328, p<0.05) positively affected buyers' trust toward suppliers. On the other hand, authority empowerment (t=2.192, p<0.05) positively affected supplier trust toward buyers. For both buyers and suppliers, the degree of authority empowerment plays a crucial role in the maintenance of their trust in each other. Hypothesis 2 tested the effects of buyerseller relational characteristics on trust. Buyers tend to trust suppliers, as suppliers make every effort to contact buyers (t=2.212, p<0.05). This tendency has also been shown to be much stronger for suppliers (t=2.591, p<0.01). On the other hand suppliers trust buyers because suppliers perceive buyers as being similar to themselves (t=2.702, p<0.01). This finding confirmed the results of Crosby, Evans, and Cowles (1990), which reported that suppliers and buyers build relationships through regular meetings, either for business or personal matters. Hypothesis 3 tested the effects of trust on perceived risk. It has been found that for both suppliers and buyers the lower is the trust, the higher is the perceived risk (t=-6.621, p<0.01 for buyers; t=-2.437, p<0.05). Interestingly, this tendency has been shown to be much stronger for buyers than for suppliers. One possible explanation for this higher level of perceived risk is that buyers normally perceive higher risks than do suppliers in transactions involving business services. For this reason, it is necessary for suppliers to implement risk reduction strategies for buyers. Hypothesis 4 tested the effects of trust on information searching. It has been found that for both suppliers and buyers, contrary to expectation, trust depends on their partner's reputation (t=2.929, p<0.01 for buyers; t=2.711, p<0.05 for suppliers). This finding shows that suppliers with good reputations tend to be trusted. Prior experience did not show any significant relationship with trust for either buyers or suppliers. Hypothesis 5 tested the effects of trust on supplier/buyer selection. Unlike buyers, suppliers tend to trust buyers when they think that previous transactions with buyers were important (t=2.913 p<0.01). However, this study did not show any significant relationship between source loyalty and the trust of buyers in suppliers. Hypothesis 6 tested the effects of trust on relational performances. For buyers and suppliers, financial performance reportedly improved when they trusted their partners (t=2.301, p<0.05 for buyers; t=3.692, p<0.01 for suppliers). It is interesting that this tendency was much stronger for suppliers than it was for buyers. Similarly, competitiveness was reported to improve when buyers and suppliers trusted their partners (t=3.563, p<0.01 for buyers; t=3.042, p<0.01 for suppliers). For suppliers, efficiency and productivity were reportedly improved when they trusted buyers (t=2.673, p<0.01). Other performance indices showed insignificant relationships with trust. The findings of this study have some strategic implications. First and most importantly, trust-based transactions are beneficial for both suppliers and buyers. As verified in the study, financial performance can be improved through efforts to build and maintain mutual trust. Similarly, competitiveness can be increased through the same kinds of effort. Second, trust-based transactions can facilitate the reduction of perceived risks inherent in the purchasing situation. This finding has implications for both suppliers and buyers. It is generally believed that buyers perceive higher risks in a highly involved purchasing situation. To reduce risks, previous studies have recommended that suppliers devise risk-reducing tactics. Moving beyond these recommendations, the present study uniquely focused on the bilateral perspective of perceived risk. In other words, suppliers are also susceptible to perceived risks, especially when they supply services that require very technical and sophisticated manipulations and maintenance. Consequently, buyers and suppliers must solve problems together in close collaboration. Hence, mutual trust plays a crucial role in the problem-solving process. Third, as found in this study, the more authority a salesperson has, the more he or she can be trusted. This finding is very important with regard to tactics. Building trust is a long-term assignment; however, when mutual trust has not been developed, suppliers can overcome the problems they encounter by empowering a salesperson with the authority to make certain decisions. This finding applies to suppliers as well.

  • PDF

Steel Plate Faults Diagnosis with S-MTS (S-MTS를 이용한 강판의 표면 결함 진단)

  • Kim, Joon-Young;Cha, Jae-Min;Shin, Junguk;Yeom, Choongsub
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.47-67
    • /
    • 2017
  • Steel plate faults is one of important factors to affect the quality and price of the steel plates. So far many steelmakers generally have used visual inspection method that could be based on an inspector's intuition or experience. Specifically, the inspector checks the steel plate faults by looking the surface of the steel plates. However, the accuracy of this method is critically low that it can cause errors above 30% in judgment. Therefore, accurate steel plate faults diagnosis system has been continuously required in the industry. In order to meet the needs, this study proposed a new steel plate faults diagnosis system using Simultaneous MTS (S-MTS), which is an advanced Mahalanobis Taguchi System (MTS) algorithm, to classify various surface defects of the steel plates. MTS has generally been used to solve binary classification problems in various fields, but MTS was not used for multiclass classification due to its low accuracy. The reason is that only one mahalanobis space is established in the MTS. In contrast, S-MTS is suitable for multi-class classification. That is, S-MTS establishes individual mahalanobis space for each class. 'Simultaneous' implies comparing mahalanobis distances at the same time. The proposed steel plate faults diagnosis system was developed in four main stages. In the first stage, after various reference groups and related variables are defined, data of the steel plate faults is collected and used to establish the individual mahalanobis space per the reference groups and construct the full measurement scale. In the second stage, the mahalanobis distances of test groups is calculated based on the established mahalanobis spaces of the reference groups. Then, appropriateness of the spaces is verified by examining the separability of the mahalanobis diatances. In the third stage, orthogonal arrays and Signal-to-Noise (SN) ratio of dynamic type are applied for variable optimization. Also, Overall SN ratio gain is derived from the SN ratio and SN ratio gain. If the derived overall SN ratio gain is negative, it means that the variable should be removed. However, the variable with the positive gain may be considered as worth keeping. Finally, in the fourth stage, the measurement scale that is composed of selected useful variables is reconstructed. Next, an experimental test should be implemented to verify the ability of multi-class classification and thus the accuracy of the classification is acquired. If the accuracy is acceptable, this diagnosis system can be used for future applications. Also, this study compared the accuracy of the proposed steel plate faults diagnosis system with that of other popular classification algorithms including Decision Tree, Multi Perception Neural Network (MLPNN), Logistic Regression (LR), Support Vector Machine (SVM), Tree Bagger Random Forest, Grid Search (GS), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The steel plates faults dataset used in the study is taken from the University of California at Irvine (UCI) machine learning repository. As a result, the proposed steel plate faults diagnosis system based on S-MTS shows 90.79% of classification accuracy. The accuracy of the proposed diagnosis system is 6-27% higher than MLPNN, LR, GS, GA and PSO. Based on the fact that the accuracy of commercial systems is only about 75-80%, it means that the proposed system has enough classification performance to be applied in the industry. In addition, the proposed system can reduce the number of measurement sensors that are installed in the fields because of variable optimization process. These results show that the proposed system not only can have a good ability on the steel plate faults diagnosis but also reduce operation and maintenance cost. For our future work, it will be applied in the fields to validate actual effectiveness of the proposed system and plan to improve the accuracy based on the results.

A Study on the morphologic characteristics of each constitution's trunk (체간부의 사상체질별 형태학적 특징에 관한 연구)

  • Hong, Suck-chull;Lee, Su-kyung;Lee, Eui-joo;Han, Gi-hwan;Chou, Yong-jin;Choi, Chang-seok;Koh, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.10 no.1
    • /
    • pp.101-142
    • /
    • 1998
  • 1. Objects The base of classification of Sasang Constitution was the different congenital formation of organs such as lungs, spleen, liver, kidneys, and it was expanded from the viscera region of lungs, spleen, liver, kidneys to the body shape of trunk. The researched about body shape of Sasang Constitution have had points of issues which derived by measurement with hands. But this study was measured the characteristics of body shape putting in importance of anatomical position with the computerized 3-Dimension scanner, which minimized the errors of measurement, and it was abled the cubic measurement such as volume, area of cross section as well as round length. 2. Materials & Method The examinee was healthy male 40 persons and female 20 persons from 20's to 40's, who was diagnosed by the specialist of Sasang Constitutional Medicine. The body shape was measured round length, area of cross section, and volume of 31 anatomical points and the 25 hypothesis with the Rapid 3D Color Scanner Model 3030 RGB/PS. And the characteristics of each constitution's body shape was derived. 3. Results & Concousion In female, Taeumin had the largest trunk and Soeumin had the smallest trunk compared to other constitution, but Soyangin had only the smallest neck. Soeumin has the smallest round length of nipple and the $CV_{12}$, and Soyangin has the smallest breadth of ASIS. Soyangin had the smallest volume from thyroid bone to the highest points of armpits and from sternum to nipple. Taeumin had the largest volume from sternum to the $CV_{12}$ and from sternum to xiphoid process. In male, Taeumin had the largest trunk and Soeumin had the smallest trunk from the level of thyroid bone to ASIS. Soyangin has the longest distance and Soeumin has the shortest distance from nipple to the lowest of breast. Taeumin had the largest volume of trunk and Soeumin had the smallest volume of trunk. In the ration of four-Cho, Taeumin had the longest distance from the highest points of armpits to nipple and Soyangin had the shortest distance of that. Soyangin had the smallest ratio of the height of upper middle cho. Soeumin had the smallest ratio from the $CV_{12}$ to navel among trunk. In the correlation among the four Cho, Taeumin had the negative correlation between the Upper-Cho and the Lower-Middle-Cho significantly.

  • PDF

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

The Use of MTT Assay, In Vitro and Ex Vivo, to Predict the Radiosensitivity of Colorectal Cancer (In-vitro와 Ex-vivo MTT Assay를 통한 직장암의 방사선치료 감수성 예측 가능성 검증)

  • Kim, Ji-Eun;Kim, Mi-Sook;Kang, Chang-Mo;Kim, Jong-Il;Shin, Hye-Kyung;Choi, Chul-Won;Seo, Young-Seok;Ji, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.166-172
    • /
    • 2008
  • Purpose: The measurement of radiosensitivity of individuals is useful in radiation therapy. Unfortunately, the measurement of radiation survival using a clonogenic assay, which is the established standard, can be difficult and time consuming. The aim of this study is to compare radiosensitivity results obtained from the MTT and clonogenic assays, and to evaluate whether the MTT assay can be used on clinical specimens. Materials and Methods: HCT-8, LoVo, CT-26, and WiDr were the colon cancer cell lines used for this study. The clonogenic assay was performed to obtain the cell survival curves and surviving fractions at a dose of 2 Gy ($SF_2$) as the standard technique for radiosensitivity. Also, the MTT assay was performed for each of the cell lines (in vitro). To simulate clinical specimens, the cell lines were inoculated into nude mice, removed when the tumors reached 1 cm in diameter, and chopped. Next, the tumors were subjected to the same process involved with the MTT assay in vitro. The inhibition rates (IR) of 10 Gy or 20 Gy of irradiation for in vitro and ex vivo were calculated based on the optical density of the MTT assay, respectively. Results: According to $SF_2$ and the cell survival curve, the HCT-8 and WiDr cell lines were more resistant to radiation than LoVo and CT-26 (p<0.05). The IR was measured by in vitro. The MTT assay IR was 17.3%, 21%, 30% and 56.5% for the WiDr, HCT-8, LoVo and CT-26 cell lines, respectively. In addition, the IR measured ex vivo by the MTT assay was 23.5%, 26%, 38% and 53% in the HCT-8, WiDr, LoVo and CT-26 tumors, respectively. Conclusion: The radiosensitivity measured by the MTT assay was correlated with the measures obtained from the clonogenic assay. This result highlights the possibility that the MTT assay could be used in clinical specimens for individual radiosensitivity assays.