• Title/Summary/Keyword: process measurement

Search Result 5,168, Processing Time 0.036 seconds

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

A Study on the Relationship of the Loneliness, Self-esteem, and Quality of Life on the Hearing Disturbance Aged (청력 장애 노인들의 고독감, 자아 존중감 및 삶의 질과의 관계연구)

  • Lee, Hyun-Jung;Sok, So-Hyune;Kim, Kwuy-Bun
    • Journal of East-West Nursing Research
    • /
    • v.9 no.1
    • /
    • pp.35-45
    • /
    • 2004
  • This study as a cross survey study was conducted to provide basic data for more practical approach to nursing the aged, by analyzing the relationship of the loneliness, self-esteem and quality of life on the hearing disturbance aged. This study was based on the survey data from the 90 aged, who are over sity years old and resident in Seoul. In order to measure the general characteristics and subjective audition, Cantril's Ladder Scale Tool was used. For the loneliness, UCLA Loneliness Scale Tool (translated into Korean to suit the Korean environment by Kim's). In order to measure the self-esteem, Rosenberg's Self-esteem Measurement Tool (translated into Korean by Chun) was used. No's Quality of Life Measurement Tool was used to the measure the quality of life. The Data were collected by direct interviewing on the subjects for this study from August 10, 1999 to September 15, 1999. In accordance with each purpose of this study, appropriate analyzing methods such as Descriptive Statistics, T-test, and ANOVA were used in analyzing the collected data. Pearson correlation coefficient was used to test the relationship of the loneliness, self-esteem and quality of life on the hearing disturbance aged. The result of this study is as follows: 1) The average of the degrees of subjective audition was 7.22, The factors that cause the result were sex, religion, the perception of health, the married state. 2) The average of the degrees of loneliness was 55.18, The factor that cause the result was the perception of health. 3) The average of the degrees of self-esteem was 28.42, The factors that cause the result were the number of family, the number of children, the perception of health. 4) The average of the degrees of quality of life was 71.87 the factors that cause the result were age, education, the number of children, the perception of health. 5) Correlation of Loneliness, self-esteem and quality of life is the perception of loneliness showed significant negative correlation with self-esteem (r=-.466, p=.0001) and quality of life (r=-.450, p=.0001). As a result of analysis above: Because of the recognition change of the aged, it seems to them that the subjective audition scale on the hearing disturbance aged is measured by only 10-point ladder scale is inappropriate. Therefore, it is necessary that the physiologic-index can confirm more exactly should be applied to them. It is very important that the social-psychological factor that has influence on the aged should be the self-perception of health. Thus, proper development of nursing intervention should be required to process in the self-perception of health on the aged.

  • PDF

Self-Assertiveness and Sexual Experiences of Teenage Girls in Korea (십대 여학생의 성 관련 경험과 자기주장)

  • Chang, Soon-Bok;Yoo, Myung-Sook;Lee, Sun-Kyung
    • Women's Health Nursing
    • /
    • v.7 no.3
    • /
    • pp.305-316
    • /
    • 2001
  • The purpose of this study was to identify characteristics related to self assertiveness in teenage girls, and to identify the relationship between the self assertiveness and sexual experiences in teenage girls in Korea. The subjects for this study were 12,733 girls from an accessible population of 19,000 girls who were a multi-stage cluster sample from a population of 1,988,902 girls attending to 4,684 schools in the seven large cities and nine provinces of Korea. The response rate was 68.9%. Data were collected by mail from October 2 to October 28, 2000. A structured questionnaire of 125 items which included measurement of general characteristics, sexual experiences, and self-assertiveness was used. The sexual experiences were defined as dating, holding hands, putting arms on the shoulders, light kissing, French kissing, touching breasts, touching genitalia, and coitus. The self assertiveness measurement was developed by S. B. Chang et al.(2000) and has a Cronbach's alpha of .6031. Data was analyzed with SPSS 10.0 Program using descriptive statistics, reliability, and t-test. The results of this study are as follows; 1. The subjects were from 9th to 11th graders and 42.7% answered that they followed their partner's request. The range for the self assertiveness score was 7-21 out of a possible range of 7-21. The group of girls who were in vocational schools, lived away from family or in rural areas, attended night school, took part in drinking, smoking, and glue inhalation, who had cyber sex or phone sex or were exposed to pornography, and who had run away from home showed significantly lower self assertiveness scores than those without these characteristics (P<.05). 2. The group which had experience in dating(t=2.379, P=.017), French kissing (t=5.425, P=.000), touching breasts (t=8.637, P=.000), touching genitalia (t=6.057, P=.000), and coitus(t=6.057, P=.000) showed significantly lower self assertiveness scores than the group which had not had these sexual experiences. But there was no difference in the self assertiveness scores between the group which had experience of holding hands, light kissing, and using contraceptives compared to the group which did not. It can be concluded that the group which had delinquent behavior showed lower self assertiveness, and the lower self assertiveness led to unwanted sexual experiences. It is suggested that self assertiveness training be provided for the group with delinquent behavior as a first priority, and then analyze of the process of self assertiveness in relation to sexual experiences.

  • PDF

Chest-wall Surface Dose During Post-mastectomy Radiation Therapy, with and without Nonmagnetic Bolus: A Phantom Study

  • Choi, Cheon Woong;Hong, Joo Wan;Park, Cheol Soo;Ahn, Jae Ouk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.293-297
    • /
    • 2016
  • For mastectomy patients, sufficient doses of radiation should be delivered to the surface of the chest wall to prevent recurrence. A bolus is used to increase the surface dose on the chest wall, whereby the surface dose is confirmed with the use of a virtual bolus during the computerized treatment-planning process. The purpose of this study is an examination of the difference between the dose of the computerized treatment plan and the dose that is measured on the bolus. Part of the left breast of an Anderson Rando phantom was removed, followed by the attainment of computed tomography (CT) images that were used as the basis for computerized treatment plans that were established with no bolus, a 3 mm-thick bolus, a 5 mm-thick bolus, and a 10 mm-thick bolus. For the computerized treatment plan, a prescribed dose regimen was dispensed daily and planning target volume (PTV) coverage was applied according to the RTOG 1304 guidelines. Using each of the established computerized treatment plans, chest-wall doses of 5 points were measured; this chest-wall dose was used as the standard for the analysis of this study, while the level of significance was set at P < 0.05. The measurement of the chest-wall dose with no bolus is 1.6 % to 10.3 % higher, and the differences of the minimum average and the maximum average of the five measurement points are -13.8 and -1.9, respectively (P < 0.05); however, when the bolus was used, the dosage was measured as 3.7 % to 9.2 % lower, and the differences of the minimum average and the maximum average are 7.4 and 9.0, -1.2 and 17.4, and 8.1 and 19.8 for 3 mm, 5 mm, and 10 mm, respectively (P < 0.05). As the thickness of the bolus is increased, the differences of the average surface dose are further increased. There are a variety of factors that affect the surface dose on the chest wall during post-mastectomy radiation therapy, for which verification is required; in particular, a consideration of the appropriate thickness and the number of uses when a bolus is used, and which has the greatest effect on the surface dose on the chest wall, is considered necessary.

Analysis of Logistics Network between Gwangyang Port and China Ports using Fuzzy-AHP (Fuzzy-AHP를 이용한 광양항과 중국항만간의 물류네트워크 분석)

  • Yeun, Dong-Ha;Choi, Yong-Seok
    • Journal of Korea Port Economic Association
    • /
    • v.27 no.4
    • /
    • pp.91-107
    • /
    • 2011
  • This paper is concerned about applying the Fuzzy-AHP(Analytic Hierarchy Process) for an analysis of logistics network between Gwangyang port and China ports. In this study, measurement areas were selected for hardware aspect, software aspect, and marketing aspect. As for the analysis regarding measurement area, the results were shown as follows: a marketing aspect(38.7%) as the first rank: a hardware aspect(35.3%) as the second rank: a software aspect(26.0%) as the third rank. The analysis result of hardware aspect reveals that the most important element is regular route addition between Gwangyang port and China ports(45.2%). The most important element of software and marketing aspect were a government support(46.4%) and a high value transshipment cargo inducement(36.4%). As for the whole priority which conversion weight was applied, the results were shown as follows: a regular route addition between Gwangyang port and China ports(15.9%) as the first rank: a high value transshipment cargo inducement(14.1%) as the second rank: a attracting import cargo from China(12.9%) as the third rank. The result of this study suggests some guidelines for deciding priority of logistics network between Gwangyang port and China ports.

A Study on the Stress Measurement in a Plastic Product using Chemical Cracking Method (케미칼 크랙킹 방법을 이용한 플라스틱 제품의 응력측정에 관한 연구)

  • Won, S.T.;Kim, T.B.;Lee, S.;Won, J.M.;Cha, K.H.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.47 no.4
    • /
    • pp.336-340
    • /
    • 2012
  • Residual stress in the injection molded part is originated from thermal shrinkage and shear stress during injection molding process. There are many measurement methods of residual stress in the plastic part. Residual stress in opaque products can be measured by chemical cracking test. This method enables the solvent and specimen to react and to cause cracks. Cracks developed according to the level of residual stress. Thus the stresses in plastic part can be quantitatively measured by counting the number of cracks or measuring the size of cracks. Relationship between stress and number of cracks in a plastic specimen has been investigated in this study. Bergen jig was used to give a strain in the specimens those were molded using PC/PBT and PC/ABS. Solvent for the chemical cracking test was prepared using tetrahydrofuran and methyl alcol with the ratio of 1 to 3. Stresses in the specimen can be calculated by strains those were imposed by Bergen jig. Cracks were developed for stress higher than certain level. The number of cracks increased by second order function for stress.

The Characteristics of the Wafer Bonding between InP Wafers and $\textrm{Si}_3\textrm{N}_4$/InP (Direct Wafer Bonding법에 의한 InP 기판과 $\textrm{Si}_3\textrm{N}_4$/InP의 접합특성)

  • Kim, Seon-Un;Sin, Dong-Seok;Lee, Jeong-Yong;Choe, In-Hun
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.890-897
    • /
    • 1998
  • The direct wafer bonding between n-InP(001) wafer and the ${Si}_3N_4$(200 nm) film grown on the InP wafer by PECVD method was investigated. The surface states of InP wafer and ${Si}_3N_4$/InP which strongly depend upon the direct wafer bonding strength between them when they are brought into contact, were characterized by the contact angle measurement technique and atomic force microscopy. When InP wafer was etched by $50{\%}$ HF, contact angle was $5^{\circ}$ and RMS roughness was $1.54{\AA}$. When ${Si}_3N_4$ was etched by ammonia solution, RMS roughness was $3.11{\AA}$. The considerable amount of initial bonding strength between InP wafer and ${Si}_3N_4$/InP was observed when the two wafer was contacted after the etching process by $50{\%}$ HF and ammonia solution respectively. The bonded specimen was heat treated in $H^2$ or $N^2$, ambient at the temperature of $580^{\circ}C$-$680^{\circ}C$ for lhr. The bonding state was confirmed by SAT(Scannig Acoustic Tomography). The bonding strength was measured by shear force measurement of ${Si}_3N_4$/InP to InP wafer increased up to the same level of PECVD interface. The direct wafer bonding interface and ${Si}_3N_4$/InP PECVD interface were chracterized by TEM and AES.

  • PDF

Development of Battery-free SAW Integrated Microsensor for Real Time Simultaneous Measurement of Humidity and $CO_2$ component (습도와 $CO_2$ 농도의 실시간 동시감지를 위한 무전원 SAW 기반 집적 센서 개발)

  • Lim, Chun-Bae;Lee, Kee-Keun;Wang, Wen;Yang, Sang-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2009
  • A 440MHz wireless and passive surface acoustic wave (SAW) based chemical sensor was developed on a $41^{\circ}YX\;LiNbO_3$ piezoelectric substrate for simultaneous measurement of $CO_2$ gas and relative humidity (RH) using a reflective delay line pattern as the sensor element. The reflective delay line is composed of an interdigital transducer (IDT) and several shorted grating reflectors. A Teflon AF 2400 and a hydrophilic $SiO_2$ layer were used as $CO_2$ and water vapor sensitive films. The coupling of mode (COM) modeling was conducted to determine optimal device parameters prior to fabrication. According to simulation results, the device was fabricated and then wirelessly measured using the network analyzer. The measured reflective coefficient $S_{11}$ in the time domain showed high signal/noise (S/N) ratio, small signal attenuation, and few spurious peaks. In the $CO_2$ and humidity testing, high sensitivity ($2^{\circ}/ppm$ for $CO_2$ detection and $7.45^{\circ}/%$RH for humidity sensing), good linearity and repeatability were observed in the $CO_2$ concentration ranges of $75{\sim}375ppm$ and humidity levels of $20{\sim}80%$RH. Temperature and humidity compensations were also investigated during the sensitivity evaluation process.

  • PDF

Electrical Characteristics of RRAM with HfO2 Annealing Temperatures and Thickness (HfO2 열처리 온도 및 두께에 따른 RRAM의 전기적 특성)

  • Choi, Jin-Hyung;Yu, Chong Gun;Park, Jong-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.663-669
    • /
    • 2014
  • The electrical characteristics of RRAM with different annealing temperature and thickness have been measured and discussed. The devices with Pt/Ti top electrode of 150nm, Pt bottom electrode of 150nm, $HfO_2$ oxide thickness of 45nm and 70nm have been fabricated. The fabricated device were classified by 3 different kinds according to the annealing temperature, such as non-annealed, annealed at $500^{\circ}C$ and annealed at $850^{\circ}C$. The set and reset voltages and the variation of resistance with temperatures have been measured as electrical properties. From the measurement, it was found that the set voltages were decreased and the reset voltage were increased slightly, and thus the sensing window was decreased with increasing of measurement temperatures. It was remarkable that the device annealed at $850^{\circ}C$ showed the best performances. Although the device with thickness of 45nm showed better performances in the point of the sensing window, the resistance of 45nm devices was large relatively in the low resistive state. It can be expected to enhance the device performances with ultra thin RRAM if the defect generation could be reduced at the $HfO_2$ deposition process.

Design of TMO Model based Dynamic Analysis Framework: Components and Metrics (TMO모델 기반의 동적 분석 프레임워크 설계 : 구성요소 및 측정지수)

  • Jeong, Yoon-Seok;Kim, Tae-Wan;Chang, Chun-Hyon
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.7
    • /
    • pp.377-392
    • /
    • 2005
  • A lot of studies to measure and analyze the system performance have been done in areas such as system modeling, performance measurement, monitoring, and performance prediction since the advent of a computer system. Studies on a framework to unify the performance related areas have rarely been performed although many studies in the various areas have been done, however. In the case of TMO(Time-Triggered Message-Triggered Object), a real-time programming model, it hardly provides tools and frameworks on the performance except a simple run-time monitor. So it is difficult to analyze the performance of the real-time system and the process based on TMO. Thus, in this paper, we propose a framework for the dynamic analysis of the real-time system based on TMO, TDAF(TMO based Dynamic Analysis Framework). TDAF treats all the processes for the performance measurement and analysis, and Provides developers with more reliable information systematically combining a load model, a performance model, and a reporting model. To support this framework, we propose a load model which is extended by applying TMO model to the conventional one, and we provide the load calculation algorithm to compute the load of TMO objects. Additionally, based on TMO model, we propose performance algorithms which implement the conceptual performance metrics, and we present the reporting model and algorithms which can derive the period and deadline for the real-time processes based on the load and performance value. In last, we perform some experiments to validate the reliability of the load calculation algorithm, and provide the experimental result.