• Title/Summary/Keyword: process measurement

Search Result 5,168, Processing Time 0.035 seconds

The Comparison of Eye Movement in Measuring Tasks between the Underachievers and the Overachievers (측정과제에서 학습부진아와 학습우수아의 안구운동 비교)

  • Choi, Hyun-Dong;Shin, Won Sub;Shin, Dong-Hoon
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.1
    • /
    • pp.181-194
    • /
    • 2014
  • The purpose of this study was to analyze the difference between eye movements according to science achievement of elementary school students on measuring tasks. Science achievement was graded by the results of Korea national achievement test conducted in 2012. As an assessment tool to check measuring task, two measuring measure problems from TSPS(Test of Science Process Skill; developed in 1994) which were suitable for eye tracking system were adopted. The subjects of this study were 3 underachievers and 3 overachievers from 6th grade who agreed to participate in the research. SMI was used to collect EMD (eye movement data). Experiment 3.2 and BeGaze 3.2 programs were used to plan experiment and analyze EMD. As a result, eye movements of participants in measuring task did not show the path to the common gaze by groups. To solve the problem of using specific measuring strategies related to the correct answer. Underachiever who failed in measuring tasks don't have enough measurement capabilities and lack eye movement through the area of interest for cognitive thinking. These results show that elementary school science curriculum dealing with measuring have to reflect a lot of step-by-step learning requires.

Design of a New Harmonic Noise Frequency Filtering Down-Converter in InGaP/GaAs HBT Process

  • Wang, Cong;Yoon, Jae-Ho;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.2
    • /
    • pp.98-104
    • /
    • 2009
  • An InGaP/GaAs MMIC LC VCO designed with Harmonic Noise Frequency Filtering(HNFF) technique is presented. In this VCO, internal inductance is found to lower the phase noise, based on an analytic understanding of phase noise. This VCO directly drives the on-chip double balanced mixer to convert RF carrier to IF frequency through local oscillator. Furthermore, final power performance is improved by output amplifier. This paper presents the design for a 1.721 GHz enhanced LC VCO, high power double balance mixer, and output amplifier that have been designed to optimize low phase noise and high output power. The presented asymmetric inductance tank(AIT) VCO exhibited a phase noise of -133.96 dBc/Hz at 1 MHz offset and a tuning range from 1.46 GHz to 1.721 GHz. In measurement, on-chip down-converter shows a third-order input intercept point(IIP3) of 12.55 dBm, a third-order output intercept point(OIP3) of 21.45 dBm, an RF return loss of -31 dB, and an IF return loss of -26 dB. The RF-IF isolation is -57 dB. Also, a conversion gain is 8.9 dB through output amplifier. The total on-chip down-converter is implanted in 2.56${\times}$1.07 mm$^2$ of chip area.

Concept Analysis of Post Intensive Care Syndrome (집중치료 후 증후군에 관한 개념분석)

  • Kang, Ji yeon;Won, Youn Hui
    • Journal of Korean Critical Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.55-65
    • /
    • 2015
  • Purpose: The purpose of this study was to identify the attributes, antecedents, and consequences of post-intensive care syndrome. Methods: The study was conducted in accordance with Walker and Avant's conceptual analysis process. We searched the Medline, ProQuest, Google scholar, NANET (Korean National Assembly Library), and RISS (Korean Education and Research Information Service) databases resulting in 29 studies for in-depth review. Results: The attributes of post-intensive care syndrome include (1) new or worsening impairment persisting after discharge, (2) physical impairment, (3) psychological impairment, (4) cognitive impairment, and (5) symptom experience. The antecedents of the concept include a critical condition that requires intensive care, stressful events, immobility, sedation, delirium, insomnia, frailty, and invasive procedures. The consequences of post-intensive care syndrome are increased dependency in activities of daily life, decreased social interaction, delayed return to previous occupation, decreased quality of life, familial post-intensive care syndrome, and readmission/death. Conclusion: The concept of post-intensive care syndrome has multifaceted and integrative features. Further research needs to be conducted to develop a measurement tool that reflects the attributes of the concept and to develop multidisciplinary interventions to prevent post-intensive care syndrome.

Concept Analysis of Psychological Resistance to Antihypertensive Medication (고혈압환자의 약물치료에 대한 심리적 저항의 개념분석)

  • Jang, Hee Soon;Kong, Kyoung Ran;Lee, Eun Nam;Kang, Jiyeon;Jang, Moon Jung
    • Journal of Korean Critical Care Nursing
    • /
    • v.9 no.2
    • /
    • pp.48-60
    • /
    • 2016
  • Purpose: The purpose of this study was to identify the attributes of the concept, of psychological resistance to antihypertensive medication. Methods: The study was conducted in accordance with Walker and Avant's conceptual analysis process. We reviewed 47 related studies selected from 4 international and Korean databases including Medline, CINAHL, NDSL, and RISS to perform the analytical processes from January 1980 to September 2015. Results: The attributes of psychological resistance to antihypertensive medication include 1) reservation, 2) opposition, 3) denial, 4) refusal, and 5) seeking alternative therapy. The antecedents of the concept can be classified into patient factors such as reactance trait and knowledge deficit, provider factors, interpersonal factors, and environmental factors. The consequences of psychological resistance to antihypertensive medication are non-compliance, deterioration of the disease, developing complications, increased anxiety, and changes in life. Conclusions: The concept of psycho logical resistance to antihypertensive medication can provide guidance for the development of an intervention program that promotes the compliance to medication regimen of hypertensive patients. Further research needs to be done to develop a measurement tool for psychological resistance to antihypertensive medication.

  • PDF

Large-Scale Turbulent Vortical Structure Inside a Sudden Expansion Cylinder Chamber (급 확대부를 갖는 실린더 챔버 내부 유동의 큰 척도 난류 보텍스 구조에 관한 연구)

  • Seong, Hyeong-Jin;Go, Sang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.7
    • /
    • pp.905-914
    • /
    • 2001
  • A large eddy simulation(LES) is performed for turbulent flow around a bluff body inside a sudden expansion cylinder chamber, a configuration which resembles a premixed gas turbine combustor. To promote turbulent mixing and to accommodate flame stability, a flame holder is installed inside the combustion chamber. The Smagorinsky model is employed and the calculated Reynolds number is 5,000 based on the bulk velocity and the diameter of the inlet pipe. The simulation code is constructed by using a general coordinate system based on the physical contravariant velocity components. The predicted turbulent statistics are evaluated by comparing them with the laser-doppler velocimetry (LDV) measurement data. The agreement of LES with the experimental data is shown to be satisfactory. Emphasis is placed on the time-dependent evolutions of turbulent vortical structure behind the flame holder. The numerical flow visualizations depict the behavior of large-scale vortices. The turbulent mixing process behind the flame holder is analyzed by visualizing the sectional views of vortical structure.

Creep Analysis of Type 316LN Stainless Steel by Reference Stress Concept (참조응력 개념에 의한 316LN 강의 크리프 해석)

  • Kim, Woo-Gon;Kim, Dae-Whan;Ryu, Woo-Seog
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.123-128
    • /
    • 2001
  • The creep constants which are used to the reference stress equations of creep damage were obtained to type 316LN stainless steel, and their determining methods were described in detail. Typical Kachanov and Rabotnov(K-R) creep damage model was modified into the damage equations with reference stress concepts, and the modified equations were applied practically to type 316LN stainless steel. In order to determine the reference stress value, a series of high-temperature tensile tests and creep tests were accomplished at $550^{\circ}C$ and $600^{\circ}C$. By using the experimental creep data, the creep constants used in reference stress equations could be obtained to type 316LN stainless steel, and a creep curve on rupture strain was predicted. The reference stress concept on creep damage can be utilized easily as a design tool to predict creep life because the process, which is quantified by the measurement of voids or micro cracks during creep, is omitted.

  • PDF

Robust Optimization of a Resonant-type Micro-probe Using Gradient Index Based Robust Optimal Design Method (구배 지수에 근거한 강건 최적 설계 기법을 이용한 공진형 미소탐침의 강건 최적화)

  • Han, Jeong-Sam;Kwak, Byung-Man
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1254-1261
    • /
    • 2003
  • In this paper we present a simple and efficient robust optimal design formulation and its application to a resonant-type micro probe. The basic idea is to use the Gradient Index (GI) to improve robustness of the objective and constraint functions. In the robust optimal design procedure, a deterministic optimization for performance of MEMS structures is followed by design sensitivity analysis with respect to uncertainties such as fabrication errors and change of operating conditions. During the process of deterministic optimization and sensitivity analysis, dominant performance and uncertain variables are identified to define GI. The GI is incorporated as a term of objective and constraint functions in the robust optimal design formulation to make both performance and robustness improved. While most previous approaches for robust optimal design require statistical information on design variations, the proposed GI based method needs no such information and therefore is cost-efficient and easily applicable to early design stages. For the micro probe example, robust optimums are obtained to satisfy the targets for the measurement sensitivity and they are compared in terms of robustness and production yield with the deterministic optimums through the Monte Carlo simulation.

  • PDF

Transverse Piezoelectric Coefficient ($e_{31,f}$) of Thick PZT films Fabricated by Sol-Gel Method with Thicknesses, Electrode Shapes and Poling Process (Sol-Gel 법으로 제조된 후막 PZT의 두께, 전극형상 및 분극 공정에 따른 $e_{31,f}$ 특성)

  • Park, Joon-Shik;Yang, Seong-Jun;Park, Kwang-Bum;Yoon, Dae-Won;Park, Hyo-Derk;Kim, Sung-Hyun;Kang, Sung-Goon;Choi, Tae-Hoon;Lee, Nak-Kyu;Na, Kyoung-Hoan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1326-1331
    • /
    • 2003
  • Thick PZT films are required for the cases of micro actuators and sensors with high driving force, high breakdown voltage and high sensitivity, and so on. In this work, thick PZT films were fabricated by Sol-Gel multi-coating method. Total 8 types of samples using thick PZT films with thicknesses, about $1{\mu}m$ and $2{\mu}m$, and Pt top electrodes shapes for measuring transverse piezoelectric coefficient ($e_{31,f}$) were fabricated using MEMS processes. They were characterized by fabricated e31,f measurement system before and after poling. $e_{31,f}$ values of samples after poling were higher than before poling. Those of $2{\mu}m$ thick PZT films were also higher than $1{\mu}m$ thick PZT films. And those with long electrodes as top electrodes were also higher than shorter.

  • PDF

Velocity Field Measurement of Flow Around a Surface-Mounted Vertical Fence Using the Two-Frame PTV System (2-프레임 PTV를 이용한 수직벽 주위 유동장 해석)

  • Baek, Seung-Jo;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1340-1346
    • /
    • 1999
  • The turbulent shear flow around a surface-mounted vertical fence was investigated using the two-frame PTV system. The Reynolds number based on the fence height(H) was 2950. From this study, it is revealed that at least 400 instantaneous velocity field data are required for ensemble average to get reliable turbulence statistics, but only 100 field data are sufficient for the time-averaged mean velocity information. Various turbulence statistics such as turbulent intensities, turbulence kinetic energy and Reynolds shear stress were calculated from 700 instantaneous velocity vector fields. The fence flow has an unsteady recirculation region behind the fence, followed by a slow relaxation to the flat-plate boundary layer flow. The time-averaged reattachment length estimated from the streamline distribution is about 11.2H. There exists a region of negative Reynolds shear stress near the fence top due to the highly convex (stabilizing) streamline-curvature of the upstream flow. The large eddy structure in the separated shear layer seems to have significant influence on the development of the separated shear layer and the reattachment process.

Measuring Apparatus for Convective Heat Transfer Coefficient of Nanofluids Using a Thermistor Temperature Sensor (더미스터 온도센서를 이용한 나노유체의 대류열전달계수 측정 장치)

  • Lee, Shin Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.2
    • /
    • pp.103-110
    • /
    • 2016
  • Fine wires made from platinum have been used as sensors to evaluate the convection performance of nanofluids. However, the wire sensor is difficult to handle due to its fragility. Additionally, an unrealistic convective heat transfer coefficient (h) is obtained if a rigorous calibration process combined with precision equipment is not used for measurement. This paper proposes a new evaluation apparatus for h of nanofluids that uses a thermistor sensor instead of the platinum wire. The working principles are also explained in detail. Validation experiments for pure engine oil comparing h from the two sensors confirmed numerous practical benefits of the thermistor. The proposed system can be used as a useful tool to justify the adoption of developed nanofluids.