• Title/Summary/Keyword: process measurement

Search Result 5,168, Processing Time 0.04 seconds

Design of a Microwave Radiometer Receiver for Soil Moisture monitoring (토양 수분 모니터링용 마이크로파 라디오미터 수신기 설계)

  • Son, Hong-Min;Park, Hong-Kyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.173-180
    • /
    • 2014
  • The development process of a L-Band microwave radiometer for remote sensing of soil-moisture are described in this paper. Achieving the development aim of the measurement accuracy within 2% for soil moisture content of 0~50%, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented to satisfy these requirements and specifications. The receiver has the bandwidth of 40 MHz, the system gain of 50 dB and the sensitivity of average value 0.19 K, maximum value 0.313K at 1390 MHz.

A Study on Physical Properties and Adsorption Characteristics of Heavy Metal Ions of Loess (황토의 물리적 특성 및 수용액중의 중금속 이온의 흡착 특성에 관한 연구)

  • 정의덕;김호성;박경원;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.491-496
    • /
    • 1999
  • Removal of Cu(II), Cr(III) and Pb(II) ions from aqueous solutions using the adsorption process on the loesses has been investigated. Variations of contact time, pH, adsorption isotherms and selectivity of coexisting ions were experimental parameters. pH of KJ and YIK samples diluted to 1% solution, was rearly the same with each value of pH 5.58 and 5.49, and both samples showed weak acidic properties. From chemical analysis, both samples contain remarkably different amounts of ${SiO}_{2}$, ${Al}_{2}O_{3}$ and ${Fe}_{2}O_{3}$. From XRD measurement, quartz was mainly observed in both samples. Kaolinite was also observed, also in both samples, but Feldspar was only observed in KJ sample. Adsorption of metal ions on the loesses were reached at equilibrium by shaking for about 30min. The adsorption of Cr(III) ion was higher than that of Cu(II) oand Pb(II) ions. The order of amount adsorbed among the investigated ions was Cr(III)>Pb(II)>Cu(II). In acidic solution, the adsorptivity of loesses was increased as pH increased. The adsorption of Cr(III) ion on the loesses were fitted to the Freundlich isotherms. Freundlich constants(1/n) of KJ and YIK loesses were 0.54 and 0.55, respectively.

  • PDF

Adsorption Characteristics of Pb(II), Cu(II), Cr(III), and Zn(II) Ions by Domestic Loess Minerals (국내산 황토를 이용한 수용액중의 Pb(II), Cu(II), Cr(III) 및 Zn(II) 이온의 흡착 특성)

  • 정의덕;김호성;원미숙;윤장희;박경원;백우현
    • Journal of Environmental Science International
    • /
    • v.8 no.4
    • /
    • pp.497-502
    • /
    • 1999
  • Removal of Pb(Ⅱ), Cu(Ⅱ), Cr(Ⅲ), and Zn(Ⅱ) ions from aqueous solutions using the adsorption process on domestic loess minerals has been investigated. Variations of contact time, pH, adsorption isotherms and selectivity of coexisting ions and leachate were experimental parameters. YDI, YPT and KRT samples diluted in 1% aquous solution which was adjusted pH 10.8, 8.0 and 6.50, respectively. The result of XRD measurement, Quartz was mainly observed in all samples. In the case of KRT sample, Kaolinite, Feldspar, Chlorite consisting of clay minerals shows almost same pattern with YPT samples. Different properties showed from the YDI sample containing Iillite, remarkably. For all the metals, maximum adsorption was observed at 30min∼60min. Adsorption of metal ions on loess minerals were reached an equilibrium by shaking the solution for about 30min. Removal efficiency of Pb(Ⅱ) ion for KRT, YPT and YDI were 84.7%, 92% and 100%, respectively. The Cu(Ⅱ) and Zn(Ⅱ) adsorptivity on KRT showed the low in various pH solution However, those on YPT and YDI were high than 90% except for the pH 2 solution. The orders of adsorptivities for domestic loess minerals showed as following : YPT>KRT>YDI. The adsorption isotherms of Cu(Ⅱ) and Zn(Ⅱ) ions on clay minerals were fitted to a Freundlich's. Freundlich constants(1/n) of KRT and YPT domestic loess minerals were 0.63, 0.97 and 0.36, 0.25, respectively.

  • PDF

Development and Field Assessment of DO Control System in an Aeration Tank for Automation of Sewage Treatment Plant

  • Jung, In-Chul;Kim, Dae-Yong;Junq, Byung-Gil
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.603-608
    • /
    • 2009
  • Activated sludge sewage treatment processes are difficult to be controlled because of their complex and nonlinear behaviour, however, the control of the dissolved oxygen level in the reactors plays an important role in the operation of the facility. For this reason, this study is designed to present a system which accurately measures DO, MLSS, pH and ORP in the aeration tank to alleviate situations above and provide the automatization of a sewage treatment plant (STP) using new DO control system. The automatic control systems must be guaranteed the accuracy. Therefore, the proposed automatic DO control system in this study could be commercial applications in the aeration tanks by means of operating cost analysis and user-friendly for operation and maintenance. We could get accurate data from the lab tank which has water quality checker because there was no vortex and air bubble during the measurement process. Improvement of confidence in the lab tank enabled effective and automatic operation of sewage treatment plants so that operation costs and manpower could be saved. If this result is put in place in every sewage treatment plant nationwide for practical purposes, it is estimated to cost 18.5 million dollars in installing the lab tank and to save 9.8 million dollars in management cost a year, except for cost saved by automation.

A Unified Potentiostat for Electrochemical Glucose Sensors

  • Sohn, Ki-Sung;Oh, Seok-Jae;Kim, Eui-Jin;Gim, Jeong-Min;Kim, Nam-Soo;Kim, Yeong-Seuk;Kim, Jong-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.5
    • /
    • pp.273-277
    • /
    • 2013
  • A unified potentiostat circuit for both $O_2$- and $H_2O_2$- based electrochemical glucose sensors was proposed and its function was verified by circuit simulations and measurement results of a fabricated chip. This circuit consisted of an operational amplifier, a comparator and current mirrors. The proposed circuit was fabricated with a $0.13{\mu}m$ thick oxide CMOS process and an active area of $360{\mu}m{\times}100{\mu}m$. The measurements revealed an input operation range from 0.5 V to 1.6 V in the $H_2O_2$- based bio-sensor and from 1.7 V to 2.6 V in the $O_2$- based bio-sensor with a supply voltage of 3.3 V. The evaluation results showed that the proposed potentiostat circuit is suitable for measuring the electrochemical cell currents of both $O_2$- and $H_2O_2$- based glucose sensors.

GPS Integrity Monitoring Method Using Auxiliary Nonlinear Filters with Log Likelihood Ratio Test Approach

  • Ahn, Jong-Sun;Rosihan, Rosihan;Won, Dae-Hee;Lee, Young-Jae;Nam, Gi-Wook;Heo, Moon-Beom;Sung, Sang-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.563-572
    • /
    • 2011
  • Reliability is an essential factor in a navigation system. Therefore, an integrity monitoring system is considered one of the most important parts in an avionic navigation system. A fault due to systematic malfunctioning definitely requires integrity reinforcement through systematic analysis. In this paper, we propose a method to detect faults of the GPS signal by using a distributed nonlinear filter based probability test. In order to detect faults, consistency is examined through a likelihood ratio between the main and auxiliary particle filters (PFs). Specifically, the main PF which includes all the measurements and the auxiliary PFs which only do partial measurements are used in the process of consistency testing. Through GPS measurement and the application of the autonomous integrity monitoring system, the current study illustrates the performance of the proposed fault detection algorithm.

Performance Comparison of GPS Fault Detection and Isolation via Pseudorange Prediction Model based Test Statistics

  • Yoo, Jang-Sik;Ahn, Jong-Sun;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.797-806
    • /
    • 2012
  • Fault detection and isolation (FDI) algorithms provide fault monitoring methods in GPS measurement to isolate abnormal signals from the GPS satellites or the acquired signal in receiver. In order to monitor the occurred faults, FDI generates test statistics and decides the case that is beyond a designed threshold as a fault. For such problem of fault detection and isolation, this paper presents and evaluates position domain integrity monitoring methods by formulating various pseudorange prediction methods and investigating the resulting test statistics. In particular, precise measurements like carrier phase and Doppler rate are employed under the assumption of fault free carrier signal. The presented position domain algorithm contains the following process; first a common pseudorange prediction formula is defined with the proposed variations in pseudorange differential update. Next, a threshold computation is proposed with the test statistics distribution considering the elevation angle. Then, by examining the test statistics, fault detection and isolation is done for each satellite channel. To verify the performance, simulations using the presented fault detection methods are done for an ideal and real fault case, respectively.

Design of Low Complexity Human Anxiety Classification Model based on Machine Learning (기계학습 기반 저 복잡도 긴장 상태 분류 모델)

  • Hong, Eunjae;Park, Hyunggon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1402-1408
    • /
    • 2017
  • Recently, services for personal biometric data analysis based on real-time monitoring systems has been increasing and many of them have focused on recognition of emotions. In this paper, we propose a classification model to classify anxiety emotion using biometric data actually collected from people. We propose to deploy the support vector machine to build a classification model. In order to improve the classification accuracy, we propose two data pre-processing procedures, which are normalization and data deletion. The proposed algorithms are actually implemented based on Real-time Traffic Flow Measurement structure, which consists of data collection module, data preprocessing module, and creating classification model module. Our experiment results show that the proposed classification model can infers anxiety emotions of people with the accuracy of 65.18%. Moreover, the proposed model with the proposed pre-processing techniques shows the improved accuracy, which is 78.77%. Therefore, we can conclude that the proposed classification model based on the pre-processing process can improve the classification accuracy with lower computation complexity.

Multiple Target Tracking using Target Feature Information (표적의 형상정보를 활용한 다중표적 추적 기법)

  • Kim, Sujin;Jung, Young-Hun;Kang, Jaewung;Yoon, Joohong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.5
    • /
    • pp.890-900
    • /
    • 2016
  • This paper presents a multiple target tracking system using target feature information. In the proposed system, the state of target is defined as its kinematic as well as feature : the kinematic includes a location and a velocity; the feature contains the image correlation between a prior target and a current measurement. The feature information is used for generating the validation matrix and association probability of joint probabilistic data association (JPDA) algorithm. Through the Kalman filter, the target kinematic is updated. Then the tracking information is cycled by the track management algorithm. The system has been evaluated using the images obtained from Electro-Optics/ InfraRed (EO/IR) sensor. It is verified that the proposed system can reduce the complexity burden of JPDA process and can enhance the track maintenance rate.

Measurement of partial discharge point in power transformer using crosscorrelation (상호상관을 이용한 변압기내의 부분방전 위치측정)

  • 문영재;구춘근;정찬수;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.6
    • /
    • pp.34-41
    • /
    • 1993
  • This paper describes an effort to develop a microcomputer-based parameter identification system for three phase and two phase brushless DC motor. Back EMF equation is derived from back EMF waveform of three phase and two phase brushless DC motor. In this paper, a new identification algorithm for the brushless DC motor parameters by Pasek's technique is de veloped. It is found that Pasek's equation is valid for the brushless DC motor, too. The results obtained clearly shows that it is possible to implement the identification system for the determination of the brushless DC motor parameters. To minimize errors due to the ripple component in the measured armature current, dlgital averaging filter is employed. The whole identification process of signal generation, measuring, parameter determination is fully automated. The use of the pmpased method in the parameter identification system shows that the averaged current curve is in excellent agreement with the estimated current curve. Therefore, this close agreement conf i i the validity of this technique.

  • PDF