• Title/Summary/Keyword: process measurement

Search Result 5,167, Processing Time 0.035 seconds

Development of 3D-based On-Machine Measurement Operating System

  • Yoon Gil-Sang;Heo Young-Moo;Kim Gun-Hee;Cho Myeong-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.3
    • /
    • pp.45-50
    • /
    • 2005
  • This paper proposed an efficient manufacturing system using the OMM (on-machine measurement) system. The OMM system is software-based 3D modeler for inspection on machine, and it is interfaced with machine tools via RS232C. The software is composed of two inspection modules; one is touch probe operating module, and the other is laser displacement sensor operating module. The module for touch probe needs the inspection feature extracted from CAD data. The touch probe moves to workpiece by three operating modes as follows: manual, general and automatic mode. The operating module of the laser displacement sensor is used to inspect profiles and very small holes. An advantage of this inspection method is the ability to execute on-line inspection during machining or afterward. The efficiency of proposed system which can predict and define the machining errors of each process was verified, so the developed system was applied to inspect a mold-base (cavity, core).

Phase Doppler Measurements and Probability Density Functions in Liquid Fuel Spray (연료분무의 위상도플러 측정과 확률밀도함수의 도출)

  • 구자예
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1039-1049
    • /
    • 1994
  • The intermitternt and transient fuel spray have been investigated from the simultaneous measurement of droplet sizes and velocities by using Phase/Doppler Particle Analyzer(PDPA). Measurement have been done on the spray axis and at the edge of the spray near nozzle at various gas-to-liquid density ratios(.rho./sub g//.rho./sub l/) that ranges from those found in free atmospheric jets to conditions typical of diesel engines. Probability density distributions of the droplet size and velocity were obtained from raw data and mathematical probability density functions which can fit the experimental distribations were extracted using the principle of maximum likelihood. In the near nozzle region on the spray axis, droplet sizes ranged from the lower limit of the measurement system to the order of nozzle diameter for all (.rho./sub g/ /.rho./sub l/) and droplet sizes tended to be small on the spray edge. At the edge of spray, average droplet velocity peaked during needle opening and needle closing. The rms intensity is greatly incresed as the radial distance from the nozzle is increased. The probability density function which can best fit the physical breakage process such as breakup of fuel drops is exponecially decreasing log-hypebolic function with 4 parameters.

An Algorithm on Optimum Weighting Design in Beamforming for Acoustic Measurement (음향측정을 위한 빔형성에서의 최적 가중상수 설계 기법)

  • Dho, Kyeong-Cheol;Son, Kweon;Lee, Yong-Gon;Son, Kyung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.8
    • /
    • pp.61-67
    • /
    • 1999
  • This paper proposes a new beamforming algorithm for acoustic measurement by using the nested linear array. In this algorithm, the weighting is optimized by minimizing the LMS error with the initial value obtained by FIR filter design algorithm. The optimization process is applied to each sub-band, which is divided from the octave band, to produce the uniform directivity index. For the optimization pseudo inverse matrix is used for the transfer matrix. As the simulation results, it is found that the proposed algorithm can get the desired beam pattern and unform directivity index so as to be used efficiently for the acoustic measurement by using a nested linear array.

  • PDF

Experimental studies on mass transport in groundwater through fracture network using artificial fracture model

  • Tsuchihara Takeo;Yoshimura Masahito;Ishida Satoshi;Imaizumi Masayuki;Ohonishi Ryouichi
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.676-683
    • /
    • 2003
  • A laboratory experiment using artificial fracture rocks was used to understand the 3-dimensional dispersion of a tracer and the mixing process in a fractured network. In this experiment, 12cm polystyrene foam cubes with two electrodes for monitoring electric conductivity (EC) were used as artificial fractured rocks. Distilled water with 0.5mS/m was used as a tracer in water with 35mS/m and the difference of EC between the tracer and the water was monitored by a multipoint simultaneous measurement system of electrical resistance. The results showed that even if the fracture arrangement pattern was not straight in the direction of the flow, the tracer did not diffuse along individual fractures and an oval tracer plume, which was the distribution of tracer concentrations, tended to be form in the direction of the flow. The vertical cross section of the tracer distribution showed small diffusivity in the vertical direction. The calculated total tracer volume passing through each measurement point in the horizontal cross section showed while that the solute passed through measurement points near the direction of hydraulic gradient and in other directions, the passed tracer volumes were small. Using Peclet number as a criterion, it was found that the mass distribution at the fracture intersection was controlled in the stage of transition between the complete mixing model and the streamline routing model.

  • PDF

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.

An Adaptive Equalizer for High-Speed Receiver using a CDR-Assisted All-Digital Jitter Measurement

  • Kim, Jong-Hoon;Lim, Ji-Hoon;Kim, Byungsub;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.2
    • /
    • pp.155-167
    • /
    • 2015
  • An adaptive equalization scheme based on all-digital jitter measurement is proposed for a continuous time linear equalizer (CTLE) preceding a clock and data recovery (CDR) in a receiver circuit for high-speed serial interface. The optimum equalization coefficient of CTLE is determined during the initial training period based on the measured jitter. The proposed circuit finds automatically the optimum equalization coefficient for CTLE with 20", 30", 40" FR4 channel at the data rate of 5 Gbps. The chip area of the equalizer including the adaptive controller is 0.14 mm2 in a $0.13{\mu}m$ process. The equalizer consumes 12 mW at 1.2 V supply during the normal operation. The adaptive equalizer has been applied to a USB3.0 receiver.

A Study on the Strain Measurement of Structure object by Electronic Process and Laser Interferometry (전자처리 및 Laser간섭에 의한 구조물의 Strain 측정에 관한 연구)

  • Jung, W.K.;Kim, K.S.;Yang, S.P.;Jung, H.C.;Kim, J.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.40-49
    • /
    • 1995
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interferometry (ESPI) method, in measuring two - dimensional in-plane displacement. The anyalysis result of measurement by ESPE is quite comparable to that tof measurement by strain gauge method. This implies that the method of ESPE is a very effective tool in non-contact two-dimensional in-plane strain analysis. But there is a controversal point, measurment error. This error is discussed to be affected not by ESPE method itself, but by its analysis scheme of the interference fringe, where the first-order interpolation has been applied to the points of strain measured. In this case, it is turned out that the more errors would be occurred in the large interval of fringe. And so this paper describes a computer method for drawing when the height is available only for some arbitrary collection of points. The method is based on a distance-weighted, last- squares approximation technique with the weight varying with the distance of the data points.

  • PDF

Experimental Analysis of GDL Degradation in PEM Fuel Cell (고분자전해질형 연료전지 가스확산층의 내구 성능 저하에 관한 실험적 분석)

  • Ha, Tae-Hun;Park, Jae-Man;Cho, Jun-Hyun;Min, Kyoung-Doug;Lee, Eun-Suk;Jung, Ji-Young;Kim, Do-Hun;Jin, Yong-Won;Lee, Dae-Han
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.132-132
    • /
    • 2009
  • To achieve the commercialization of PEM fuel cell, the durability problem must be solved. Recently, many researchers have focused on this durability problem and degradation studies about membrane and electrode have been reported. But durability characteristics of gas diffusion layer is not much reported yet. Durability of GDL is very important to maintain the performance of PEM fuel cell because the main function of GDL is a path of fuel and water and the GDL degradation causes the loss of the GDL function. In this study, the degradation of GDL, especially, the mechanical degradation process was investigated with the leaching test. The effect of water dissolution was observed through the test and the amount of GDL degradation was measured with various measurement methods such as weight measurement, static contact angle measurement, scanning electron microscope. After 2,000 hours test, the GDL showed structural damage and loss of hydrophobicity.

  • PDF

A Study on Shape Measurement by Using Electronic Speckle Pattern Interferometry (전자 스페클 패턴 간섭법을 이용한 형상 측정에 관한 연구)

  • 강영준;김계성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.156-164
    • /
    • 1998
  • Electronic Speckle Pattern Interferometry(ESPI) has been used to measure surface deformations of engineering components and materials in industrial areas. ESPI, a non-contact and non-destructive technique, is capable of providing full-field results with high spatial resolution and high speed. One of the important application using electronic speckle pattern interferometry is electronic speckle contouring of a diffused object for 3-D shape analysis and topography measurement. Generally the electronic speckle contouring is suitable for providing measurement range from millimeters to several centimeters. In this study, we introduce the contouring method by modified dual-beam speckle pattern interferometer and the shift of the two illumination beams through optical fiber in order to obtain the contour fringe patterns. We also describe formation process of depth contour fringes and grid contour fringes by shifting direction of the two illumination beams. Before the experiments, we performed the geometric analysis for dual-beam-shifted ESPI contouring, and then, the electronic speckle contouring experiment with various specimens. For quantitative analysis of the contour fringes, we used 4-frame phase shifting method with PZT Finally, good agreement between the geometric analysis and experimetal results is obtained.

  • PDF

Optimization Methodology of Quality Measurement of Digital Correlator (디지털 상관기 성능 측정의 최적화 기법)

  • Yeom, Jae-Hwan;Jeong, Goo-Young;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Kwang-Dong;Lee, Chang-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.371-372
    • /
    • 2006
  • In this paper, we propose a method that measures quality of digital correlator. Quality of digital correlator in field of image composition of radio astronomy have as important position for acquisition of radio wave image with high precision. Digital correlator should have wide bandwidth and high precision to study on deep space. Digital correlator, therefore, should be designed to have high speed processing and high precision. But, real time measurement of quality of digital correlator using acquisition data is difficult to compare accuracy of result because digital correlator should process a large quantity of data with high speed. Measurement method of quality, also, has intricate implementation of experiment equipment. this paper present methods that compose experiment equipment without external installation easily and verify quality of digital correlator perfectly.

  • PDF