• Title/Summary/Keyword: probe design

Search Result 473, Processing Time 0.024 seconds

A Study on PZT-5A Probe for Nondestructive Inspection (비파괴검사를 위한 PZT-5A 탐촉자에 관한 연구)

  • 황현석
    • Electrical & Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.119-125
    • /
    • 1997
  • In this study, piezoelectric transducers were designed and manufactured using PZT-5A which had relatively high electromechanical coefficient, nondestructive testing system was developed which was able to inspect automatically using stepping motors, PC-Lab, and PC-Scope. The optimum design conditions for NDT were presented and verified comparing PZT-5A probes with comercial probes. It was proved by simulation and experiments that Epoxy is a good material as matching and backing layers. The envelope was reduced 60% with matching layer and 76% with matching and backing layer. NDT was successfully carried out for aluminum test pieces. Distance error of PZT-5A probe was 2.8%.

  • PDF

Design and Fabrication of Microlens Illuminated Aperture Array for Optical ROM Card System (Optical Card 시스템에서의 마이크로렌즈 조사 광프로브 어레이 설계 및 제작)

  • Kang, Shin-Ill;Kim, Seok-Min;Kim, Hong-Min;Lee, Jee-Seung;Lim, Ji-Seok;Busch, Christopher
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • An optical ROM card system which using an optical probe array generated by Talbot effect was proposed as new robust storage solution. To improve the optical density and to decrease the power consumption of the system, it is very important to make the spot sizes of optical probes smaller as well as to increase the optical efficiency from the light source to optical probes. In this study, a microlens illuminated aperture array for generating high efficiency optical probe away with small beam spot was designed and fabricated using monolithic lithography integration method. The maximum intensity of optical probes of microlens illuminated aperture array increased about 12 times of that of aperture array, and the full width half maximum of the optical probe at Talbot plane generated by microlens illuminated aperture array was $0.77{\mu}m$.

  • PDF

A Study on the Optimal Probe Path Generation for Sculptured Surface Inspection Using the Coordinate Measuring Machine (3차원 측정기를 이용한 자유곡면 측정시 최적의 경로 결정에 관한 연구)

  • Cho, Myung-Wo;Yi, Seung-Jong;Kim, Moon-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.121-129
    • /
    • 1995
  • The objective of this research is to develop an effective inspection planning strategy for sculptured surfaces by using 3-dimensional Coordinate Measuring Machine (CMM). First, the CAD/CAM database is generated by using the Bezier surface patch mathod and variable cutter step size approach for design and machining of the workpiece model. Then, optimum measuring point locations are determained based on the mean curvature analysis to obtain more effective inspection results for the given sample numbers. An optimal probe sequence generation method is proposed by implementing the Traveling Salesperson (TSP) algorithm and new guide point selection methods are suggested based on the concepts of the variable distance between the first and second guide points. Finally, simulation study and experimental work show the effectiveness of the proposed strategy.

  • PDF

Study on Frictional Characteristics of Sub-micro Structured Silicon Surfaces (서브 마이크로 구조를 가진 실리콘 표면의 마찰 특성 연구)

  • Han, Ji-Hee;Han, Gue-Bum;Jang, Dong-Yong;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.92-97
    • /
    • 2017
  • The understanding of the friction characteristics of micro-textured surface is of great importance to enhance the tribological properties of nano- and micro-devices. We fabricate rectangular patterns with submicron-scale structures on a Si wafer surface with various pitches and heights by using a focused ion beam (FIB). In addition, we fabricate tilted rectangular patterns to identify the influence of the tilt angle ($45^{\circ}$ and $135^{\circ}$) on friction behaviour. We perform the friction test using lateral force microscopy (LFM) employing a colloidal probe. We fabricate the colloidal probe by attaching a $10{\pm}1-{\mu}m$-diameter borosilicate glass sphere to a tipless silicon cantilever by using a ultraviolet cure adhesive. The applied normal loads range between 200 nN and 1100 nN and the sliding speed was set to $12{\mu}m/s$. The test results show that the friction behavior varied depending on the pitch, height, and tilt angle of the microstructure. The friction forces were relatively lower for narrower and deeper pitches. The comparison of friction force between the sub-micro-structured surfaces and the original Si surface indicate an improvement of the friction property at a low load range. The current study provides a better understanding of the influence of pitch, height, and tilt angle of the microstructure on their tribological properties, enabling the design of sub-micro- and micro-structured Si surfaces to improve their mechanical durability.

Development of Diaphragm-type Stylus Probe for Ultra-precision On-machine Measurement Application (초정밀 기상측정용 다이아프램 타입 접촉식 프로브의 개발)

  • Lee, Jung-Hoon;Lee, Chan-Hee;Choi, Joon-Myeong;Kim, Ho-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.8
    • /
    • pp.845-852
    • /
    • 2012
  • The diaphragm-type stylus probe was developed for ultra-precision on-machine measurement (OMM) application. This probe is equipped with two diaphragms which are parallel and one capacitive sensor is used for detecting the vertical motion of end tip in the stylus when it is contacted to the optical freeform surface. For better performance of proposed probes, several design parameters such as axial stiffness and the lateral deformations were investigated with finite element analysis techniques. To verify the feasibility, the profiles of the master sphere ball were measured on the ultra-precision milling machine. The measurement results show that the proposed probe can calculate the radius of the circle within the accuracy of 0.1 ${\mu}m$ for the ultraprecision optical surface.

Design of Shielded Encircling Send-Receive Type Pulsed Eddy Current Probe Using Numerical Analysis Method

  • Shin, Young-Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.505-510
    • /
    • 2013
  • An encircling send-receive type pulsed eddy current (PEC) probe is designed for use in aluminum tube inspection. When bare receive coils located away from the exciter were used, the peak time of the signal did not change although the distance from the exciter increased. This is because the magnetic flux from the exciter coil directly affects the receive coil signal. Therefore, in this work, both the exciter and the sensor coils were shielded in order to reduce the influence of direct flux from the exciter coil. Numerical simulation with the designed shielded encircling PEC probe showed the corresponding increase of the peak time as the sensor distance increased. Ferrite and carbon steel shields were compared and results of the ferrite shielding showed a slightly stronger peak value and a quicker peak time than those of the carbon steel shielding. Simulation results showed that the peak value increased as the defect size (such as depth and length) increased regardless of the sensor location. To decide a proper sensor location, the sensitivity of the peak value to defect size variation was investigated and found that the normalized peak value was more sensitive to defect size variation when the sensor was located closer to the exciter.

The simulator loop probe style magnetic stimulation design for a nervous system treatment (신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터)

  • Kim, Whi Young
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension (자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구)

  • 김의석;안형준;장인배;한동철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

Design of Hybrid Network Probe Intrusion Detector using FCM

  • Kim, Chang-Su;Lee, Se-Yul
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2009
  • The advanced computer network and Internet technology enables connectivity of computers through an open network environment. Despite the growing numbers of security threats to networks, most intrusion detection identifies security attacks mainly by detecting misuse using a set of rules based on past hacking patterns. This pattern matching has a high rate of false positives and can not detect new hacking patterns, making it vulnerable to previously unidentified attack patterns and variations in attack and increasing false negatives. Intrusion detection and prevention technologies are thus required. We proposed a network based hybrid Probe Intrusion Detection model using Fuzzy cognitive maps (PIDuF) that detects intrusion by DoS (DDoS and PDoS) attack detection using packet analysis. A DoS attack typically appears as a probe and SYN flooding attack. SYN flooding using FCM model captures and analyzes packet information to detect SYN flooding attacks. Using the result of decision module analysis, which used FCM, the decision module measures the degree of danger of the DoS and trains the response module to deal with attacks. For the performance evaluation, the "IDS Evaluation Data Set" created by MIT was used. From the simulation we obtained the max-average true positive rate of 97.064% and the max-average false negative rate of 2.936%. The true positive error rate of the PIDuF is similar to that of Bernhard's true positive error rate.

System Design and H/W Development of the Residual Stress Measurement for Ferromagnetic thin Sheet (강자성 박판소재의 잔류응력 측정 시스템의 설계 및 제작)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.2
    • /
    • pp.50-57
    • /
    • 2001
  • Magnetic inductive probe was designed and assembled for sensing the residual stress developed in the ferromagnetic thin sheet. The residual stress measurement system with this probe could resolve the residual stresses developed in the sheet in terms of principal stress orientation, and magnitude of the principal stress. It was consumed that the obtained probe output voltage from the qualified ferromagnetic Fe-42Ni lead frame sheet and quality-rejected sheet is effectively determined using the developed device. The lead frame sheet which has accumulated a high level of residual stress always showed a distinctive stress distribution and magnitude compared with those of qualified lead frame sheet. Those differences were well resolved as functions of input current or used frequency.

  • PDF