• Title/Summary/Keyword: prisms

Search Result 129, Processing Time 0.025 seconds

Experimental Study of Steel Fiber Concrete Slabs Part I: Behavior under Uniformly Distributed Loads

  • Ellouze, Ali;Ouezdou, Mongi Ben;Karray, Mohammed Ali
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.2
    • /
    • pp.113-118
    • /
    • 2010
  • This article aims to study the effects of adding steel fibers to concrete on the mechanical behavior of steel fiber concrete (SFC) slabs. After formulating the SFC, an experimental work was, first, conducted on $160\;{\times}\;320$ mm cylindrical specimens and $70\;{\times}\;70\;{\times}\;280$ mm prisms. Then, this study was carried out on 20 rectangular $1,100\;{\times}\;1,100\;{\times}\;60$ mm small slabs submitted to a distributed load. Two types of fibers with hooked ends were used: long fibers (LF) of a length of 50 mm and short fibers (SF) of a length of 35 mm. The studied parameters are compressive and tensile strengths and Young's modulus. Plain concrete (PC) small slabs were also prepared to be compared to the SFC specimens. The results showed that the compressive strength of SFC increased up to 25% while the splitting tests showed an improvement of the SFC reaching 45%. Tests on SFC small slabs also showed that a smaller deflection is obtained with respect to PC, which indicates an improvement in strength (up to 100%), in ductility and in resistance to cracking. The LF gives a better improvement in strength than the SF for a 70% $kg/m^3$ of steel proportioning.

A QUANTITATIVE ANALYSIS OF THE IN VIVO AMALGAM CORROSION PRODUCTS (Amalgam 부식산물의 정성분석에 관한 연구)

  • Lim, Byong-Mok;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.1-17
    • /
    • 1991
  • The purpose of this study was to analyze the in vivo amalgam corrosion products qualitatively. 30 molars with large, intact amalgam restorations were selected. All the restorations were more than 5 years old. Twenty of the removed amalgams were embedded in acrylic resin block. The exposed surfaces of fifteen embedded amalgams were polished by amalgam polishing kit, and the rest were observed without polishing. The remaining 10 amalgams were fractured centrally and perpendiculary to the occlusal surface with a wire-cutter. After all specimens were cleaned ultrasonically in distilled water, each surface was examined under S.E.M. and E.D.A.X. (Energy Dispersive Micro X-ray Analyzer) to determine the morphology and chemical nature of the corrosion products. The following results were obtained: 1. The surfaces of the unpolished amalgam restorations were covered with thin amorphous layer of Sn-Ca-P-S complex with numerous cracks. 2. In the conventional amalgams, the major corrosion products were Sn-Cl phases however, tin oxide phases were also observed. 3. Only tin oxide phase was identified in the high copper amalgam, but it was less frequently observed than in the conventional amalgam. 4. It was easier to observe the corrosion product morphology in the fractured surfaces than in the polished ones. The morphologies of the corrosion product crystals looked like a stack of slightly bended plates in the Sn-Cl phases and polyhedra or polygonal prisms in the tin oxide phases.

  • PDF

Volumetric Change of Concrete Subjected to Different Curing Condition (양생 조건에 따른 콘크리트의 체적 변화)

  • Lee Kwang Myong;Lee Hoi Keun;Lee Sung Jin;Baek Biehn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.132-135
    • /
    • 2004
  • High-performance concrete (HPC) may be expected to differ from usual concrete with respect to shrinkage behavior, and it shows high autogenous shrinkage due to the use of very low water-binder ratio (w/b) and various admixtures. Therefore, in order to minimize the shrinkage stress and to ensure the service life of concrete structure, volumetric change of HPC should be understood. In this study, small prisms made of HPC with w/b of 0.32 and blast-furnace slag content of $0\%,\;30\%,\;and\;50\%$ were prepared to measure the volumetric changes such as autogenous shrinkage, drying shrinkage, and swelling under three different curing conditions. It was observed that the concrete cured. sealed condition showed only autogenous shrinkage while the concrete let to dry condition at temperature of $20^{\circ}C$ and relative humidity of $60\%$ during the test period showed both autogenous and drying shrinkage. Moreover, the concrete exposed to dry condition after 2-day water curing swelled and then started to shrink with age. The total shrinkage (autogenous+drying) of this concrete was smaller than that of the concrete cured dry condition, especially at early-age. Therefore, the early-age moisture curing is very effective to control or minimize the volumetric change and its induced stress of HPC.

  • PDF

A Study for the Control of Various Luminous Intensity Distribution in Numerical Model of Planar Prism LED Luminaire (평면 프리즘 LED 조명기구 배광수치모델의 다양한 배광 제어를 위한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.60-66
    • /
    • 2011
  • There are several technological problems have to be resolved for LEDs to be used as a general purpose light source. In addition, there are several differences between existing luminaires and the general planer LED luminaire for the intensity distribution. Therefore, the optical engineer then faces the challenging a problem of designing for a spatially extended and non-uniform light source. In the previous studies on the optical design of luminaires, a lot of studies on reflectors and light source have been conducted but the ones on prisms and lenses are insufficient at present. This study developed the numerical model of planar prism LED luminaire to control luminous intensity distribution of LED luminaires. And this study presents an optical calculation process for the prism optical design of a planar prism LED luminaire and a comparison of the simulation results between the developed numerical model and Photopia 2.0 to verify the accuracy of the numerical model. In addition, this study showed a method for the control of various luminous intensity distribution from the developed numerical model.

The Study of Vertical Fixation Disparity by Fixation Disparity Card (주시시차 카드를 이용한 수직주시시차 연구)

  • Park, Hyun-Ju;Yoon, Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: This study was performed to determine vertical fixation disparity by Fixation Disparity Card. The purpose of this study was to investigate distribution of the curve types obtained with Wesson card. Methods: Fixation disparity curves were measured on 52 subjects with the Wesson fixation disparity card. A fixation disparity curve was an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that were used to aid in the diagnosis and management of binocular vision disorders included the x-intercept, y-intercept, curve slope and curve type. Results: Vertical fixation disparity curves by Wesson Fixation Disparity Card were very various. Conclusions: Vertiical fixation disparity curves could be used to aid in the diagnosis and prescription.

Analysis of Binocular Vision by Wesson Fixation Disparity Card (Wesson Fixation Disparity Card를 이용한 양안시 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • A commonly used device to determine fixation disparity curves is the Wesson Fixation Disparity Card. A fixation disparity curve is an x, y coordinate plot of the angular amount of fixation disparity as a function of the power of prisms through which the patient views. The fixation disparity curve variables that are used to aid in the diagnosis and management of binocular vision disorders include the x-intercept, y-intercept, curve slope and curve type. Fixation disparity curves were measured on 102 subjects with the Wesson fixation disparity card. The purpose of this study is to investigate distribution of the curve types obtained with Wesson card. Fixation Disparity by Wesson Fixation Disparity Card were that in case of type I 63.0%, in case of type II 0.0%, in case of type III 25.0% and in case of type IV 12.0%.

  • PDF

Application of FE approach to deformation analysis of RC elements under direct tension

  • Jakubovskis, Ronaldas;Kupliauskas, Rimantas;Rimkus, Arvydas;Gribniak, Viktor
    • Structural Engineering and Mechanics
    • /
    • v.68 no.3
    • /
    • pp.345-358
    • /
    • 2018
  • Heterogeneous structure and, particularly, low resistance to tension stresses leads to different mechanical properties of the concrete in different loading situations. To solve this problem, the tension zone of concrete elements is reinforced. Development of the cracks, however, becomes even more complicated in the presence of bar reinforcement. Direct tension test is the common layout for analyzing mechanical properties of reinforced concrete. This study investigates scatter of the test results related with arrangement of bar reinforcement. It employs results of six elements with square $60{\times}60mm$ cross-section reinforced with one or four 5 mm bars. Differently to the common research practice (limited to the average deformation response), this study presents recordings of numerous strain gauges, which allows to monitor/assess evolution of the deformations during the test. A simple procedure for variation assessment of elasticity modulus of the concrete is proposed. The variation analysis reveals different deformation behavior of the concrete in the prisms with different distribution of the reinforcement bars. Application of finite element approach to carefully collected experimental data has revealed the effects, which were neglected during the test results interpretation stage.

Determination of the Decenter Position of a Test Lens in a Six-Sided Prism Lens Lensmeter (6면 프리즘 렌즈가 장착된 Lensmeter에서 시험 렌즈의 편심 위치 계산)

  • Lin, Maria;Park, Jong-Dae;Jo, Chang-Ho;Kim, Hyeon-Gyu
    • The Journal of Natural Sciences
    • /
    • v.16 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • We have developed an algorithm to determine the position from the image points in a lensmeter with 6-sided prism lens. The positions of the image points which are formed by six prisms depends on the decenter position of a test lens and can be calculated by skew ray tracing. The optical characteristics of the lens meter was analyzed using the Code V program and the positions of the image points was expressed as a function of the decenter position of the test lens. By minimizing the expectation error, we can determine the decenter position position of a test lens from the image positions.

  • PDF

A Comparative Analysis of Edge Detection Methods in Magnetic Data

  • Jeon, Taehwan;Rim, Hyoungrea;Park, Yeong-Sue
    • Journal of the Korean earth science society
    • /
    • v.36 no.5
    • /
    • pp.437-446
    • /
    • 2015
  • Many edge detection methods, based on horizontal and vertical derivatives, have been introduced to provide us with intuitive information about the horizontal distribution of a subsurface anomalous body. Understanding the characteristics of each edge detection method is important for selecting an optimized method. In order to compare the characteristics of the individual methods, this study applied each method to synthetic magnetic data created using homogeneous prisms with different sizes, the numbers of bodies, and spacings between them. Seven edge detection methods were comprehensively and quantitatively analyzed: the total horizontal derivative (HD), the vertical derivative (VD), the 3D analytic signal (AS), the title derivative (TD), the theta map (TM), the horizontal derivative of tilt angle (HTD), and the normalized total horizontal derivative (NHD). HD and VD showed average good performance for a single-body model, but failed to detect multiple bodies. AS traced the edge for a single-body model comparatively well, but it was unable to detect an angulated corner and multiple bodies at the same time. TD and TM performed well in delineating the edges of shallower and larger bodies, but they showed relatively poor performance for deeper and smaller bodies. In contrast, they had a significant advantage in detecting the edges of multiple bodies. HTD showed poor performance in tracing close bodies since it was sensitive to an interference effect. NHD showed great performance under an appropriate window.

CONSTRUCTION OF THE BOAO ECHELLE SPECTROGRAPH (BOES) (보현산천문대 고분산 에셀분광기(BOES) 제작)

  • KIM KANG-MIN;JANG JEONG GYUN;CHUN MOO-YOUNG;PARK BYEONG-GON;HYUNG SIEK;HAN INWOO;YOON TAE SEOG;VOGT STEVEN S.
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.119-126
    • /
    • 2000
  • The BOES (BOAO Echelle Spectrograph), a fiber-fed echelle spectrograph of the BOAO 1.8 m telescope, has been designed and now is being manufactured. The BOES follows a white pupil design collimated with two off-axis parabolic mirrors. The 136mm collimating beam leaving the 41.59 grooves/mm R4 echelle grating is refocused near the narrow folding mirror. Through the two cross-disperser prisms and $\phi250 mm(f/1.5)$ transmission camera, the beam images on EEV $2k\times4k$ CCD. The BOES can take the wavelength range of 3700 to $10100{\AA}$ at a single spot with spectral resolution R = 20000 to 40000 depending on the fiber set employed. We describe the key sciences and performance, current status of construction, and future plan of the BOES.

  • PDF