• Title/Summary/Keyword: primary dynamic resistance

Search Result 26, Processing Time 0.021 seconds

Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method (동적 시정수 기반 고성능 절연 저항 계산 기법)

  • Son, Gi-Beom;Hong, Jong-Phil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.8
    • /
    • pp.1058-1063
    • /
    • 2020
  • This paper presents a new insulation resistance calculation technique to prevent electric shock and fire accidents due to the dielectric breakdown in the primary insulation section of the IT ground system. The solar power generation market is growing rapidly due to the recent expansion of renewable energy and energy storage systems, but as the insulation is destroyed and fire accidents frequently occur, a device for monitoring the insulation resistance state is indispensable to the IT grounding method. Compared to the conventional algorithm that use a method of multiplying a time constant to a fixed coefficient, the proposed insulation resistance calculation method has a fast response time and high accuracy over a wide insulation resistance range by applying a different coefficient according to the values of the insulation impedance. The proposed dynamic time constant based insulation resistance calculation technique reduces the response time by up to 39.29 seconds and improves the error rate by 20.11%, compared to the conventional method.

Effects of Trim on Resistance Performance of a Ship (선박의 트림 자세가 저항 성능에 미치는 영향)

  • Park, Dong Woo;Lee, Sang Bong;Chung, Sung Seob;Seo, Heung Won;Kwon, Jae-Woong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.50 no.2
    • /
    • pp.88-94
    • /
    • 2013
  • The primary objective of the current work is to obviously analyze regarding effects of trim conditions of a ship on resistance performance using model test and CFD. Model tests at a towing tank are conducted to investigate resistance for trim conditions at the given same displacement. Measured resistance shows small but distinct differences according to trim conditions. However, these differences are difficult to be clarified by measured physical quantities and wave pattern analysis from model tests. CFD is employed for the assessment of resistance performance according to trim conditions. The flow computation is conducted considering free surface and dynamic trim using a commercial CFD code (STAR-CCM+). The initiative of the present work is to systematically demonstrate pressure resistance acting on each region of divided finite zones of ship surface along the length and draught direction of surface when pressure distribution on the ship is interpreted. Also, a standard to assess the pressure resistance applied on the divided regions of a ship is established.

Computational Study on the Hemodynamics of the Bypass Shunt Directly Connecting the left Ventricle to a Coronary Artery

  • Shim Eun Bo;Lee Byung Jun;Ko Hyung Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1158-1168
    • /
    • 2005
  • A shunt from the left ventricle to the left anterior descending artery is being developed for coronary artery occlusive disease, in which the shunt or conduit connects the the left ventricle (LV) with the diseased artery directly at a point distal to the obstruction. To aid in assessing and optimizing its benefit, a computational model of the cardiovascular system was developed and used to explore various design conditions. Computational fluid dynamic analysis for the shunt hemodynamics was also done using a commercial finite element package. Simulation results indicate that in complete left anterior descending artery (LAD) occlusion, flow can be returned to approximately 65% of normal, if the conduit resistance is equal for forward and reverse flow. The net coronary flow can increase to 80% when the backflow resistance is infinite. The increases in flow rate produced by asymmetric flow resistance are enhanced considerably for a partial LAD obstruction, since the primary effect of resistance asymmetry is to prevent leakage back into the ventricle during diastole. Increased arterial compliance has little effect on net flow with a symmetric shunt, but considerably augments it when the resistance is asymmetric. The computational results suggest that an LV-LAD conduit will be beneficial when the resistance due to artery stenosis exceeds 27 PRU, if the resistance is symmetric. Fluid dynamic simulations for the shunt flow show that a recirculating region generated near the junction of the coronary artery with the bypass shunt. The secondary flow is induced at the cutting plane perpendicular to the axis direction and it is in the attenuated of coronary artery.

Analysis of load-settlement behaviour of shallow foundations in saturated clays based on CPT and DPT tests

  • Mir, Mouna;Bouafia, Ali;Rahmani, Khaled;Aouali, Nawel
    • Geomechanics and Engineering
    • /
    • v.13 no.1
    • /
    • pp.119-139
    • /
    • 2017
  • Static Penetration Test (CPT) and Dynamic Penetration Test (DPT) are commonly used in-situ tests in a routine geotechnical investigation. Besides their use for qualitative investigation (lithology, homogeneity and spatial variability), they are used as practical tools of geotechnical characterization (resistance to the penetration, soil rigidity) and modern foundation design as well. The paper aims at presenting the results of an extensive research work on the evaluation of the 1D primary consolidation settlement of saturated clayey soils on the basis of the CPT or DPT tests. The work is based on an analysis of the correlations between the tip resistance to penetration measured in these tests and the parameters of compressibility measured by the compressibility oedometer test, through a local geotechnical database in the northern Algeria. Such an analysis led to the proposal of two methods of calculation of the settlement, one based on the CPT test and the other one on the DPT. The comparison between the predicted settlements and those computed on the basis of the oedometer test showed a good agreement which demonstrate the possbility to use the CPT and DPT tests as reliable tools of computation of foundation settlements in clayey soils.

Mechanosensitive Modulation of Receptor-Mediated Crossbridge Activation and Cytoskeletal Organization in Airway Smooth Muscle

  • Hai, Chi-Ming
    • Archives of Pharmacal Research
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2000
  • Recent findings indicate that mechanical strain (deformation) exerted by the extracellular matrix modulates activation of airway smooth muscle cells. Furthermore, cytoskeletal organization in airway smooth muscle appears to be dynamic, and subject to modulation by receptor activation and mechanical strain. Mechanosensitive modulation of crossbridge activation and cytoskeletal organization may represent intracellular feedback mechanisms that limit the shortening of airway smooth muscle during bronchoconstriction. Recent findings suggest that receptor-mediated signal transduction is the primary target of mechanosensitive modulation. Mechanical strain appears to regulate the number of functional G-proteins and/or phospholipase C enzymes in the cell membrane possibly by membrane trafficking and/or protein translocation. Dense plaques, membrane structures analogous to focal adhesions, appear to be the primary target of cytoskeletal regulation. Mechanical strain and receptor-binding appear to regulate the assembly and phosphorylation of dense plaque proteins in airway smooth muscle cells. Understanding these mechanisms may reveal new pharmacological targets for control1ing airway resistance in airway diseases.

  • PDF

Effect of Dyeing by Immature Persimmon Juice on the Hand of Fabrics (감즙염색이 직물의 태에 미치는 영향)

  • 고은숙;이혜선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.8
    • /
    • pp.883-891
    • /
    • 2003
  • In this study, a change of hand of fabrics dyed with persimmon juice was measured using Kawabata Evaluation System. Using various cotton fabrics, linen fabric and silk fabric used frequently for persimmon juice dyeing, we examined the changes of physical properties and hand according to persimmon juice dyeing and washing. The dynamic characteristics of hand were measured tensile, shear, bending, compression, surface properties, thickness and weight. Linearity of load-extention and tensile resilience were increased in all kinds of fabrics after dyeing. Tensile energy decreased in cotton fabric 2(gauze), cotton fabric 3(muslin) and linen fabric. Shear stiffness and hysteresis of shear increased in most of fabrics. Bending rigidity of the bending property and hysteresis of bending, linearity of compression of the compression property, compression energy and compression resilience increased in all kinds of fabrics after dyeing. Thickness and weight increased much in all kinds of fabrics after dyeing. In the primary hand value, stiffness and anti-drape stiffness increased in all kind of fabrics after dyeing. The fullness and softness, crispness, scrooping feeling and flexibility with soft feeling decreased. As the stiffness after persimmons dyeing increased, it was suitable for clothes material of summer.

Comparative study of the seismic response of RC framed buildings retrofitted using modern techniques

  • Mazza, Fabio
    • Earthquakes and Structures
    • /
    • v.9 no.1
    • /
    • pp.29-48
    • /
    • 2015
  • The main purpose of this work is to compare different criteria for the seismic strengthening of RC framed buildings in order to find the optimal combinations of these retrofitting techniques. To this end, a numerical investigation is carried out with reference to the town hall of Spilinga (Italy), an RC framed structure with an L-shaped plan built at the beginning of the 1960s. Five structures are considered, derived from the first by incorporating: carbon fibre reinforced polymer (FRP)-wrapping of all columns; base-isolation, with high-damping-laminated-rubber bearings (HDLRBs); added damping, with hysteretic damped braces (HYDBs); FRP-wrapping of the first storey columns combined with base-isolation or added damping. A three-dimensional fibre model of the primary and retrofitted structures is considered; bilinear and trilinear laws idealize, respectively, the behaviour of the HYDB, providing that the buckling be prevented, and the FRP-wrapping, without resistance in compression, while the response of the HDLRB is simulated by using a viscoelastic linear model. The effectiveness of the retrofitting solutions is tested with nonlinear dynamic analyses based on biaxial accelerograms, whose response spectra match those in the Italian seismic code.

A study on the PWM type High Speed Electromagnet (PWM 방식 고속 전자석에 관한 연구)

  • Song, Chang-Seop;Yang, Hae-Jeong;Song, Sung-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.127-135
    • /
    • 1994
  • This paper is concerned about a high speed electromagnet of Pressure control solenoid valve. Solenoid valve is controlled by means of Pulse width modulation. The magnetostatic field problem on a solenoid is numerically solved by the 2-D axisymmetric finite element method. And permeance method is adopted for analysing the static and dynamic property of solenoid part theoretically. In addition, in this study, experiments on solenoid part were performed in order to measure the magnetic force and plunger displacement. The numerical results coincided with the experimental results. As a result, the magnetic force has the linear relation with displacement of plunger and the primary factors on the performance of PWM type high speed electromagnet are coil resistance, plunger mass, and the length of air gap between plunger and core.

  • PDF

Resonance analysis of cantilever porous graphene platelet reinforced pipe under external load

  • Huang, Qinghua;Yu, Xinping;Lv, Jun;Zhou, Jilie;Elvenia, Marischa Ray
    • Steel and Composite Structures
    • /
    • v.45 no.3
    • /
    • pp.409-423
    • /
    • 2022
  • Nowadays, there is a high demand for great structural implementation and multifunctionality with excellent mechanical properties. The porous structures reinforced by graphene platelets (GPLs) having valuable properties, such as heat resistance, lightweight, and excellent energy absorption, have been considerably used in different engineering implementations. However, stiffness of porous structures reduces significantly, due to the internal cavities, by adding GPLs into porous medium, effective mechanical properties of the porous structure considerably enhance. This paper is relating to vibration analysis of fluidconveying cantilever porous graphene platelet reinforced (GPLR) pipe with fractional viscoelastic model resting on foundations. A dynamical model of cantilever porous GPLR pipes conveying fluid and resting on a foundation is proposed, and the vibration, natural frequencies and primary resonant of such a system are explored. The pipe body is considered to be composed of GPLR viscoelastic polymeric pipe with porosity in which Halpin-Tsai scheme in conjunction with the fractional viscoelastic model is used to govern the construction relation of nanocomposite pipe. Three different porosity distributions through the pipe thickness are introduced. The harmonic concentrated force is also applied to the pipe and the excitation frequency is close to the first natural frequency. The governing equation for transverse motions of the pipe is derived by the Hamilton principle and then discretized by the Galerkin procedure. In order to obtain the frequency-response equation, the differential equation is solved with the assumption of small displacement, damping coefficient, and excitation amplitude by the multiple scale method. A parametric sensitivity analysis is carried out to reveal the influence of different parameters, such as nanocomposite pipe properties, fluid velocity and nonlinear viscoelastic foundation coefficients, on the primary resonance and linear natural frequency. Results indicate that the GPLs weight fraction porosity coefficient, fractional derivative order and the retardation time have substantial influences on the dynamic response of the system.

Expression characteristic of pop art in Jean-Charles de Castelbajac's works (Jean-Charles de Castelbajac 작품에 나타난 팝아트의 표현 특성)

  • Kim, Sun Young
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.5
    • /
    • pp.688-701
    • /
    • 2014
  • This study examined the expression characteristics in pop art works of Jean-Charles de Castelbajac. The study here aimed at possibility to find a design development in building up the unique art world of creativity based on popularity, artistry, and originality without confinement to the trend only. For the research method, review of literature and analysis about Castelbajac's works reflecting the pop art feature in the collections from 2000S/S to 2012F/W were performed. The results of research are as follows. The external expression form of Castelbajac's works based on pop art was grouped roughly into use of mass culture image, appropriation of pop art expression technique, and parody of art works. First, his work appeared as application of the mass culture image such as symbolic thing in the modern consumer society, object in an ordinary life, character of well-known animation, national flag and famous star. Second, such appropriated pop art techniques showed as pop color in strong primary color and silk screen, photomontage, collage, assemblage, graffiti, and lettering. Third, a variety of images featured earlier in art works were shown in parody. These works are valuable in that they are expressed aesthetically through regeneration of popular culture's various images in view of fashion, they are described in the non-traditional value with frolic resistance and deviation out of existing fashion norm, and they are given the dynamic creativity integrated with art and fashion.