• Title/Summary/Keyword: pressured grouting

Search Result 3, Processing Time 0.018 seconds

Load transfer characteristics and bearing capacity of micropiles (마이크로파일의 하중전이특성 및 지지성능 분석)

  • Goo, Jeong-Min;Choi, Chang-Ho;Cho, Sam-Deok;Lee, Ki-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.899-904
    • /
    • 2009
  • This paper presents the analysis result of load-transfer mechanism and pile movements associated with the development of frictional resistance to understand the engineering characteristics of micropile behavior. An field load tests were performed for two different types of micropiles and they are (i) thread bar reinforcement with D=50mm and (ii) hollow steel pipe reinforcement with $D_{out}$=82.5mm and $D_{in}$=60.5mm and wrapped with woven geotextile for post-grouting. The load test results indicated that micropiling with pressured grouting provided better load-transfer characteristics than micropiling with gravity grouting under both compressive and tensile loading conditions in that unit skin frictional resistance is well distributed along installation depth. The unit weight and unconfined compressive strength of cured grout were obtained for each piling method. The strength and unit weight of micropile with pressured grouting was higher than those with gravity grouting. The fact that load bearing quality with pressured grouting is better than that of gravity grouting could be attributed to the dense mutual adhesion between surrounding ground and pile due to pressurized grouting method and better grout quality.

  • PDF

A Case Study on the Design of Tunnel Excavation in Geological Anomalies (터널굴착시 지질이상대 통과방안 설계사례 연구)

  • Yoo, Joung-Hoon;Kim, Yang-Kyun;Chung, Chul-Hwa
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.341-348
    • /
    • 2011
  • As a result of the detailed site investigation performed for the design of a 4.3 km long tunnel, geological anomalies of four fault zones and a rock boundary were discovered on the tunnel route. Most of all, it was confirmed that pyrite, which may corrode steel material, is contained inside the geological anomalies, and pressured ground water flows out of the fault fractured zone. To overcome these geological conditions, antisulfur concrete for the concrete lining and anticorrosive swelling rock bolts are designed in the pyrite-containing sections. For the sections where a great amount of groundwater outflows, water blocking methods including grouting are applied according to the result of numerical analyses on the seepage. In addition, since the past earthquakes occurred around Korea have take place mainly near fault zones, seismic analyses were performed based on the Soil-Structure Interaction (SSI) concept and the strength of concrete tunnel lining is designed to be 27 MPa from 24 MPa in order to reinforce the tunnel structure.

Improvement Effects of Cement Grouting using Vibration Method through a Field Test (현장시험을 통한 시멘트 진동주입공법의 보강효과)

  • Han, Sanghyun;Yea, Geugweun;Kim, Hongyeon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 2014
  • So far, the grouting using pressure injection has been extensively used to avoid adverse effects such as soil disturbance. Whereas, the pressure injection to the limitations of the diffusion range, so that the kinks would last injection of cement particles by introducing a frequency oscillation effect improved injection method have been recently developed. In this study, a pilot test was performed to compare injection effects of the both methods. The injections using both methods were tested on the embankment which consists of core clay and weathered soil. Subsequently, the injected volume, SPT N values, in-situ permeability and electrical resistivity were measured to compare their effects. The vibration method showed more effective permeation comparing with the pressure method. Also, it showed more homogeneously improved ground than the existing method. For SPT results, the vibration method presented increase of mean N value as much as 17.4 % comparing with the conventional method. Higher electrical resistivity was presented in case of injecting with vibration method and it indicated the injection was extensively completed. Finally, it is expected that the economic feasibility will be improved by decrease of drilling spacing, when the existing method is replaced with vibration method.