• Title/Summary/Keyword: pressure-correction method

Search Result 159, Processing Time 0.033 seconds

A Study of a Correlation between Experiments and Calculations of Pressure Fluctuation on Hull Surface (선체 변동 압력에 관한 실험과 이론의 비교 연구)

  • Moon-Chan Kim;Ki-Sup Kim;In-Haeng Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.19-26
    • /
    • 1996
  • An experimental and computational study of the pressure fluctuation induced by a propeller on a hull surface was carried out with three ship models and seven model propellers. The fluctuation of pressure on a flat plate was measured at KRISO cavitation tunnel and calculated by a panel and lifting surface method(XForShip code). To extend the measurement data on the flat plate into that on complex hull forms, the correction factor was determined as a ratio of the solid boundary factor(SBF). The computation of pressure fluctuation around complex hull forms was also performed to make the full scale prediction and compared with the corrected experimental data. The calculated values agreed well with the compensated experimental data and it was found that the correction factor was about 0.65-0.7.

  • PDF

Method of A-Weighted Sound Pressure Level Measurement for Fans, Blowers and Compressors (송풍기${\cdot}$압축기의 소음레벨 측정방법 KS B 6361의 개정)

  • Lee, Seungbae;Kim, Kyoung-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.189-199
    • /
    • 1999
  • The revision was proposed for methods A-weighted sound pressure measurement for fans, blowers and compressors in order to apply newly developed measurement techniques to KS B 6361 established in 1987. This proposal includes modification of terminologies, revision of sound power methods for radiated sound from the body, inclusion of In-duct measurement method, and correction method for flow noise upon microphon.

  • PDF

A Fundamental Study of Air-Fuel Ratio Control on LPG Liquid Injection Engines (LPG 액체분사엔진의 공연비제어에 관한 기초 연구)

  • Sim, Han-Seop;Sunwoo, Myoungho;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.7
    • /
    • pp.80-87
    • /
    • 2002
  • Liquefied petroleum gas (LPG) is used in spark ignition (SI) engines. Fuel injection rate of an injector is affected by fuel temperature and pressure in LPG liquid injection systems for either a multi-point-injection (MPI) or a direct injection (DI) engine. Even fuel injection conditions are varied, the air-fuel ratio should be accurately controlled to reduce exhaust emissions. In this study, a correction factor fur the fuel injection rate of an injector is derived from density ratio and pressure difference ratio. A compensation method of injected fuel amount is proposed for a fuel injection control system. The experimental results for the LPG liquid injection system in a SI engine show that this system works well fur a full range of engine speed and load condition, and the air-fuel ratio is accurately controlled by the proposed correction factor.

Numerical Analysis for Improving Passing Flow Rate Quantity abound a Radiator (라디에이터 통과풍량 확보를 위한 수치적 검토)

  • 김은필;강상훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.304-310
    • /
    • 2001
  • This paper describes the analysis of flow field using a projection finite element method. The projection scheme with a pressure correction is presented for the analysis of an incompressible Navier-Stokes flow. The projection scheme is analyzed numerically and applied to the well-known bench marking problems such as lid driven cavity. Finally, the projection scheme is applied to a flow through the automobiles front. In the automobiles cooling system, the flow through its front is very important to a cooling performance. The results show that the flow quantity increases by locating the position of bumper to the further front position of a car. And, the improvement on the suction part below a bumper achieves the more passing flow quantity. The attachment of an air dam increases passing flow quantity causing the pressure rise to the front part and the pressure drop beneath a car.

  • PDF

Numerical Calculations of Compressible Flows using a SIMPLE Algorithm (Simple 알고리즘을 이용한 압축성유동해석)

  • Ahn Hee-Sub;Sohn Chnng-Hyun;Moon Su-Yeon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.184-190
    • /
    • 2000
  • A well-known pressure correction method, a SIMPLE algorithm is extended to treat compressible flows. Collocated grids are used and density is linked to pressure via an equation of state. The influence of pressure on density in the case of compressible flows is implicitly incorporated into the extended SIMPLE algorithm. The first-order Upwind and high-order Quick scheme are compared with respect to an accuracy and convergence time at all speeds. The extended method is verified on a number of test cases and the results we compared with other numerical results available in the literature. The calculated results show that the Quick scheme improves accuracy at all speed and also reduces the calculation time at supersonic flows, compared with the Upwind scheme.

  • PDF

Numerical Simulation of Laminar Reacting Flows Using Unstructured Finite Volume Method With Adaptive Refinement

  • Kang, Sung-Mo;Kim, Hoo-Joong;Kim, Yong-Mo
    • Journal of the Korean Society of Combustion
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 2001
  • A pressure-based, unstructured finite volume method has been applied to couple the chemical kinetics and fluid dynamics and to capture effectively and accurately the steep gradient flame field. The pressure-velocity coupling is handled by two methodologies including the pressure-correction algorithm and the projection scheme. A stiff, operator-split projection scheme for the detailed nonequilibrium chemistry has been employed to treat the stiff reaction source terms. The conservative form of the governing equations are integrated over a cell-centered control volume with collocated storage for all transport variables. Computations using detailed chemistry and variable transport properties were performed for two laminar reacting flows: a counterflow hydrogen-air diffusion flame and a lifted methane-air triple flame. Numerical results favorably agree with measurements in terms of the detailed flame structure.

  • PDF

Numerical Calculations of Compressible Flows using a SIMPLE Algorithm (SIMPLE 알고리즘을 이용한 압축성유동해석)

  • Ahn Hee-Sub;Sohn Chang-Hyun;Moon Su-Yeon
    • Journal of computational fluids engineering
    • /
    • v.5 no.2
    • /
    • pp.1-8
    • /
    • 2000
  • A well-known pressure correction method, a SIMPLE algorithm, is extended to treat compressible flows. Collocated grids are used and density is linked to pressure via an equation of state. The influence of pressure on density in the case of compressible flows is implicitly incorporated into the extended SIMPLE algorithm. The first-order Upwind and high-order Quick scheme are compared with respect to an accuracy and convergence time at all speeds. The extended method is verified on a number of test cases and the results are compared with other numerical results available in the literature. The calculated results show that the Quick scheme improves accuracy at all speed and also reduces the calculation time at supersonic flows, compared with the Upwind scheme.

  • PDF

Aerostatic pressure of streamlined box girder based on conformal mapping method and its application

  • Wu, Lianhuo;Ju, J. Woody;Zhang, Mingjin;Li, Yongle;Qin, Jingxi
    • Wind and Structures
    • /
    • v.35 no.4
    • /
    • pp.243-253
    • /
    • 2022
  • The conformal mapping method (CMM) has been broadly exploited in the study of fluid flows over airfoils and other research areas, yet it's hard to find relevant research in bridge engineering. This paper explores the feasibility of CMM in streamlined box girder bridges. Firstly, the mapping function transforming a unit circle to the streamlined box girder was solved by CMM. Subsequently, the potential flow solution of aerostatic pressure on the streamlined box girder was obtained and was compared with numerical simulation results. Finally, the aerostatic pressure attained by CMM was utilized to estimate the aerostatic coefficient and flutter performance of the streamlined box girder. The results indicate that the solution of the aerostatic pressure by CMM on the windward side is satisfactory within a small angle of attack. Considering the windward aerostatic pressure and coefficient of correction, CMM can be employed to estimate the rate of change of the lift and moment coefficients with angle of attack and the influence of the geometric shape of the streamlined box girder on flutter performance.

Alterations in Left ventricular End-systolic Wall Stress During Short-term Follow-up After Correction of Isolated Congenital Aortic Stenosis (선천성 대동맥 협착증의 술전 및 술후 단기간의 수축말기 좌심실 내벽 스트레스의 변화)

  • 김시호
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.777-784
    • /
    • 2000
  • Congenital aortic stenosis in children is characterized by "excessive" left ventricular hypertrophy with reduced left ventricular systolic wall stress that allows for supernormal ejection performance. We hypothesized that left ventricular wall stress was decreased immediately after surgical correction of pure congenital aortic stenosis. Also measuring postoperative left ventricular wall stress was a useful noninvasive measurement that allowed direct assessment for oxygen consumption of myocardium than measuring the peak systolic pressure gradient between ascending aorta and left ventricle for the assessment of surgical results. Material and Method: Between September 1993 and August 1999, 8 patients with isolated congenital aortic stenosis who underwent surgical correction at Yonsei cardiovascular center were evaluated. There were 6 male and 2 female patients ranging in age from 2 to 11 years(mean age, 10 years). Combined Hemodynamic-Ultrasonic method was used for studying left ventricular wall stress. We compared the wall stress peak systolic pressure gradient and ejection fraction preoperatively and postoperatively. Result: After surgical correction peak aortic gradient fell from 58.4${\pm}$17.6, to 23.7${\pm}$17.7 mmHg(p=0.018) and left ventricular ejection fraction decreased but it is not statistically significant. In the consideration of some factors that influence left ventricular end-systolic wall stress excluding one patient who underwent reoperation for restenosis of left ventricular outflow tract left ventricular end-systolic pressure and left ventricular end-systolic dimension were fell from 170.6${\pm}$24.3 to 143.7${\pm}$27.1 mmHg and from 1.78${\pm}$0.4 to 1.76${\pm}$0.4 cm respectively and left ventricular posterior wall thickness was increased from 1.10${\pm}$0.2, to 1.27${\pm}$0.3cm but it was not statistically singificant whereas left ventricular end-systolic wall stress fell from 79.2${\pm}$24.9 to 57.1${\pm}$27.6 kdynes/cm2(p=0.018) in 7 patients. For one patient who underwent reoperation peak aortic gradient fell from 83.0 to 59.7 mmHg whereas left ventricular end-systolic wall stress increased from 67.2 to 97.0 kdynes/cm2 The intervals did not change significnatly. Conclusion ; We believe that probably some factors that are related to left ventricular geometry influenced the decreased left ventricular wall stress immediately after surgical correction of isolated congenital aortic stenosis. Left ventricular wall stress is a noninvasive measurement and can allow for more direct assesment than measuring peak aortic gradient particularly in consideration of the stress and oxygen consumption of the myocardium therefore we can conclude it is a useful measurement for postoperative assessment of congenital aortic stenosis.

  • PDF

Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols (부피법을 이용한 고압·극저온 수소 흡착량 측정 방식의 기본 원리)

  • OH, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.349-356
    • /
    • 2016
  • Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as 'volume correction using a non-porous material', showing a reliable cold volume correction.