와류 유량센서용 압전 바이몰프의 온도변화에 따른 특성 (Characteristics of Temperature Variation to the Piezoelectric Bimorph for Vortex Flowmeter)

  • 이근택;김형순;임종인
    • 한국재료학회지
    • /
    • 제17권5호
    • /
    • pp.289-292
    • /
    • 2007
  • Although piezoelectric bimorph that is using as the sensor in medical and industrial measurement has large displacement, it has problems including efficiency in generating force, energy convergence, and response. Its application is being limited based on the change in resonance frequency with temperature. In this study, to overcome the disadvantages, PZT piezoelectric ceramics was prepared and produced a parallel type piezoelectric bimorphs. In addition, by using the finite element method. the configuration of piezoelectric bimorph was designed and the displacement of the bimorph based on applied electric pressure and the wave pattern were measured. By analyzing the resonance characteristics of the bimorph in the temperature range of $-60{\sim}80^{\circ}C$, an attempt was made to study the operational characteristics and temperature reliability of vortex flowmeter sensor. As a result, the resonance frequency of the bimorph was gradually increased with the temperature from $-60{\sim}80^{\circ}C$. The deflection of the bimorph was found to strongly depend on both the applied electric field waveform and the environmental temperature.

체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현 (Development for body temperature sensor and monitoring telemetry system)

  • 이정현;성기웅;김명남;조진호
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

Surface treatment of sol-gel bioglass using dielectric barrier discharge plasma to enhance growth of hydroxyapatite

  • Soliman, Islam El-Sayed;Metawa, Asem El-Sayed;Aboelnasr, Mohamed Abdel Hameed;Eraba, Khairy Tohamy
    • Korean Journal of Chemical Engineering
    • /
    • 제35권12호
    • /
    • pp.2452-2463
    • /
    • 2018
  • Surface treatment of sol-gel bioglass is required to increase its biomedical applications. In this study, a dielectric barrier discharge (DBD) plasma treatment in atmospheric pressure was performed on the surface of [$SiO_2-CaO-P_2O_5-B_2O_3$] sol-gel derived glass. The obtained bioglass was treated by plasma using discharge current 12 mA with an exposure period for 30 min. The type of discharge can be characterized by measuring the discharge current and applied potential waveform and the power dissipation. Apatite formation on the surface of the DBD-treated and untreated samples after soaking in simulated body fluid (SBF) at $37^{\circ}C$ is characterized by Fourier transform infrared spectroscopy (FTIR), X-Ray diffraction (XRD), inductively coupled plasma (ICP-OES) and scanning electron microscopy coupled with energy dispersive spectroscopy (SEM/EDS). We observed a marked increase in the amount of apatite deposited on the surface of the treated plasma samples than those of the untreated ones, indicating that DBD plasma treatment is an efficient method and capable of modifying the surface of glass beside effectively transforming it into highly bioactive materials.

스마트폰 탈착형 혈관 탄성 모니터링 모듈 (Smartphone-Attachable Vascular Compliance Monitoring Module)

  • 양세환;엄지용
    • 전기전자학회논문지
    • /
    • 제28권2호
    • /
    • pp.221-227
    • /
    • 2024
  • 본 논문은 스마트폰 탈착형 혈관 탄성 모니터링 모듈을 제안한다. 제안하는 센서 모듈은 광용적맥파(photoplethysmogram, PPG)를 계측하고 가속도 맥파를 복원한다. 복원된 가속도 맥파로부터 특징점을 추출하며, 해당 특징점을 이용하여 혈관 탄성 수치를 추정한다. 해당 모듈은 스마트폰의 USB 단자를 통해 전원을 공급 받으며, 블루투스 방식으로 가속도 맥파 파형과 혈관 탄성 수치를 스마트폰으로 전송한다. 스마트폰으로 전송된 파형과 혈관 탄성 수치는 안드로이드 어플리케이션을 통해 화면에 디스플레이 된다. 본 연구는 PPG 계측의 일관성을 평가하는 기법을 제안하며, 해당 기법은 모듈의 프로세서 내에 구현되었다. 본 연구에서 개발한 혈관 탄성 모니터링 모듈은 PPG 신호의 계측 및 분석을 지원하지 않는 스마트폰에 쉽게 탈착이 가능한 형태로 적용이 가능하며, 혈관 탄성의 손쉬운 계측 및 수치 분석을 제공하는 특징을 지닌다. 구현된 혈관 탄성 모니터링 모듈의 성능 검증을 위해, 29명의 피험자를 대상으로 혈관 탄성 수치와 맥압을 측정하였다. 맥압은 상용 혈압계를 이용하여 획득하였으며, 해당 지표는 혈관 탄성을 나타내는 대표적 지표에 해당한다. 분석 결과, 제작된 혈관 탄성 모니터링 모듈로부터 획득한 혈관 탄성 수치와 맥압 간의 피어슨 상관계수는 0.778이며, 두 수치 간의 비교적 높은 상관 관계를 확인하였다.

$CO_2$로 포화된 사암의 속도-유효응력 반응 (Velocity-effective stress response of $CO_2$-saturated sandstones)

  • Siggins, Anthony F.
    • 지구물리와물리탐사
    • /
    • 제9권1호
    • /
    • pp.60-66
    • /
    • 2006
  • 세 개의 서로 다른 사암 샘플들 -두 개의 합성 샘플과 한 개의 현장 샘플- 에 대해 현장 저류층의 대표적인 구속압력과 공극압력하에서 초음파 시험이 수행되었다. 세가지 사암 샘플들은 (a) 캘사이트 시멘트(calcite intergranula. cement (CIPS))로 만든 합성사암, (b) 실리카 시멘트(silica intergranular cement)로 만든 합성 사암 (c) Otway Basin 의 Boggy Creek 1 시추공에서 시도되는 $CO_2$ 파일럿 프로젝트의 대상 암석층 중 Waarre 층으로부터 추출한 코아 샘플로 구성되어 있다. 공극률은 각각 32%, 33%, 26%이다. 초기시험은 실내건조(room-dried) 상태에 있는 코아들에 대해 구속응력을 5 MPa 씩 단계별로 65 MPa 까지 증가시키며 이루어졌다. 그리고 나서 모든 코아들에 처음에는 온도 $22^{\circ}C$에서 6 MPa 공극압력으로 기체상의 $CO_2$를, 그 다음에는 온도 $22^{\circ}C$ 에서 7 MPa 부터 17 MPa 까지 5 MPa 씩 증가시키면서 액체상의 $CO_2$를 주입하였다. 구속응력은 10MPa부터 65 MPa까지 달리 하였다. P와 S 초음파 파형들이 유효응력이 증가할 때마다 기록되었다. 속도-유효응력 반응들이 P 파와 S 파에 대해 실험 자료들로부터 계산되었으며, 감쇠(1/Qp)들은 스펙트럼 비 방법을 이용하여 파형들로부터 계산되었다. 각각의 사암들에 대한 이론적인 속도-유효응력 계산은 $CO_2$ 압력-밀도 와 $CO_2$ 체적계수-압력 상 다이어그램(phasediagram), Gassmann 유효 매질 이론(effective medium theory)을 이용하여 구하였다. 기체상의 $CO_2$ 주입은 속도-유효응력에서 건조상태(공기로 포화된 상태)에 비해 거의 무시할만한 변화를 가져왔다. 다양한 공극압력에서 액체상의 $CO_2$ 주입은 공기로 포화된 상태에 비해 속도-유효응력 반응을 평균 약 8% 정도 낮게 한다. 실험자료들은 높은 유효응력에서 Gassmann 계산들과 일치한다. 이러한 이론과 일치하는 "임계" 유효응력은 사암의 종류에 따라 달라진다. 이 차이는 각각의 사암 종류의 미세구조에서 미세 균열 수의 차이에 기인한 것이라 생각된다. 높은 유효응력에서의 이론과 의미있게 일치하였으며, $CO_2$ 주입 시 현장에서의 탄성파 거동을 예상하는데 있어서 어느 정도 확신을 준다.

미출산 여성과 출산 여성의 맥파 비교 - 난임 맥파 지표 연구를 위한 - (A Study on the Pulse Wave Parameter in Non Delivery and Delivery Women)

  • 서창운;김경철;김이순
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.200-215
    • /
    • 2012
  • Objectives : The purpose of this study is to investigate the differences of pulse wave parameter between the non delivery group (single women with no childbirth experience) and the delivery group (married women who gave birth(s) in delivery). Methods : Sixty one healthy (non delivery) nulliparous women and fifty three delivery women participated in this study. We used 3 dimensional pulse analyser(3D MAC, DAEYOMEDI co., Korea), which measures radial pulse waveform non-invasively by way of tonometry method at 5 different applied pressure levels. From 114 subjects enrolled, pulse wave parameters were measured on the six locations of Chon, Kwan and Cheok of each hands. Results : Delivery group's pulse showed larger values in the following pulse wave parameters (Energy, Ap, RAI, As, Aw, h1, h2, h4, h4/h1, t, t1, t2, t4, Wm, Wm/t). Non delivery group's pulse indicated larger values in the pulse wave parameters such as Energy of left Chon, difference pulse energy between left and right hand, Ad, h5, h5/h1, t5. Conclusions : According to the analysis result, delivery group's pulse has bigger values in most part of pulse wave parameters, especially in Kwan and Cheok which correspond to Liver, Kidney, and Myeong-mun. We interpret these results that delivery women are more mature and stable in reproductive organs than non delivery group, as they have experienced delivery(deliveries) and child-caring through married life.

편측성 안면경련 환자의 미세혈관 감압수술에서 효과적인 수술 중 신경계 감시검사를 위한 제안 (Suggestions for the Effective Intraoperative Neurophysiological Monitoring in Microvascular Decompression Surgery of Hemifacial Spasm)

  • 임성혁
    • 대한임상검사과학회지
    • /
    • 제48권3호
    • /
    • pp.262-268
    • /
    • 2016
  • 편측성 안면경련(hemifacial spasm)은 불수의적으로 안면의 근육에서 발작적인 경련이 일측성으로 반복해서 발생하는 질환이다. 한 근육의 수축으로 인해 동시적으로 여러 근육이 동시에 수축되는 동시 수축성(synkinesia)이 특징이다. 발병원인은 제 7뇌신경인 안면신경이 혈관에 의해 압박을 받아서 나타나게 된다. 본 연구는 편측성 안면경련 환자의 미세혈관 감압 수술을 받은 환자를 대상으로 수술 중 진행되는 신경계 감시검사 방법들에 대해 다루었다. 청각유발전위 검사에서는 수술용 뇌 견인기의 사용시 주의 사항과 검사시기에 대해 언급하였다. 안면신경의 근전도검사에서는 잡파의 혼입과 신경손상 시 근전도 파형의 감별에 대해, 측면전파 반응 검사에서는 마취의 유지의 중요성에 대해 그리고 체성감각 유발전위검사에서는 환자를 좀더 자세하게 검사할 수 있도록 새로운 방법을 제안하였다. 위에 언급한 내용들을 토대로 검사한다면 수술 중 신경계 감시 검사를 원활하게 할 수 있으리라 생각된다.

다중모드 지원 자동차폐 순음청력검사 시스템 개발 (Development of Auto-Masking Puretone Audiometer supporting Multiple Modes)

  • 김진동;신범주;전계록;왕수건
    • 한국산학기술학회논문지
    • /
    • 제10권6호
    • /
    • pp.1229-1236
    • /
    • 2009
  • 최소가청역치를 측정하기 위한 기기인 순음청력검사 시스템은 사운드카드를 가진 컴퓨터에서 소프트웨어로 구현될 경우 가격 경쟁력을 가질 수 있다. 본 논문에서는 일반 PC를 기반으로 설계 및 구현된 순음청력검사 시스템을 기술한다. 개발된 PC 기반 순음청력검사 시스템은 기도 및 골도 검사시 지동 차폐 기능도 지원한다. 또한 자가 검사, 자동 검사 및 수동 검사 모드로 구성되는 다중 모드를 제공함으로써 집이나 병원 등 다양한 환경에서 사용될 수 있도록 설계되었다. 본 연구에서는 구현된 시스템의 출력 전압 파형과 출력 음압 측정을 통해 정상적으로 동작함을 검증하였다.

MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법 (Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • 제28권6호
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

백색 LED 보정 공정 적용을 위한 고점도 형광체 미세 정량토출 공정 (Fine Dispensing Process of High Viscosity Phosphor for Repairing Application of White LED)

  • 양봉수;양영진;김형찬;고정범;조경호;도양회
    • 한국생산제조학회지
    • /
    • 제25권2호
    • /
    • pp.124-131
    • /
    • 2016
  • Several research works for finding and optimizing the methods of dispensing high viscosity phosphor used in the fabrication of white LED's are currently in progress. High viscosity phosphor dispensing with a high accuracy is crucial because the dispensing rate and uniformity directly affect parameters such as the CIE chromaticity diagram, color temperature and luminous flux of white LED's. This study presents a novel method of dispensing high viscosity phosphor using electrohydrodynamic printing. The dispensing rate was optimized less than 0.01 mg phosphor using experiments and optimizing the process parameters including the standoff distance from the nozzle to the substrate, ink supply pressure, and multi-step pulsed waveform magnitude ratio. The dispensing rate was measured by dispensing 20 dots using drop-on-demand with the optimized parameters, and the experiments were repeated 10 times to maximize the data accuracy. The average dispensing rate that can be reliably used for high viscosity phosphor dispensing was 0.0052 mg.